BACKGROUND: Point-of-care testing (POCT) is widely used to measure blood glucose levels in people with diabetes, although its use in measuring glycated hemoglobin (HbA1c) levels is less common, perhaps due to perceived performance issues and access to the technology.
METHODS: Forty blood samples were analyzed in duplicate using Bayer's A1CNow + ® Multi-Test A1C system (A1CNow + ) with 3 different reagent lots; HbA1c levels of the samples spanned the clinically relevant range of 4% to 10%. Corresponding samples were sent to a National Glycohemoglobin Standardization Program (NGSP) secondary reference laboratory (University of Missouri Secondary Reference Laboratory #9), which analyzed the samples with a Tosoh Automated Glycohemoglobin Analyzer HLC-723G8 (Tosoh G8; Tosoh Bioscience, Inc).
RESULTS: Glycated hemoglobin levels measured with the A1CNow + aligned with measurements obtained using the laboratory method, with correlation coefficients of 0.985, 0.987, and 0.989 for the 3 lots, respectively. The 95% CIs for the differences between the A1CNow + levels and the mean HbA1c levels were within -0.55% to +0.50% for the 3 reagent lots, which is well within the currently acceptable limits of ±0.75% HbA1c required by the NGSP. Results were further analyzed per the new tighter NGSP performance criteria effective September 1, 2012, requiring that 37 of 40 results be within ±7% (relative bias) of the NGSP reference laboratory measures. All 3 lots met the tighter NGSP criteria.
CONCLUSION: The A1CNow + provides accuracy and precision when performing POCT of HbA1c as an aid in diabetes management. Ongoing improvements in this and other HbA1c POCT devices may lead to a greater global acceptance of the role of POCT of HbA1c in diabetes management.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23748510     DOI: 10.3810/pgm.2013.05.2664

Source DB:  PubMed          Journal:  Postgrad Med        ISSN: 0032-5481            Impact factor:   3.840


  12 in total

1.  Assessment of the performance of A1CNow(+) and development of an error grid analysis graph for comparative hemoglobin A1c measurements.

Authors:  Fusong Jiang; Xuhong Hou; Jun Lu; Jian Zhou; Fengdi Lu; Kai Kan; Junling Tang; Yuqian Bao; Weiping Jia
Journal:  Diabetes Technol Ther       Date:  2014-04-25       Impact factor: 6.118

Review 2.  Impact of HbA1c Testing at Point of Care on Diabetes Management.

Authors:  Oliver Schnell; J Benjamin Crocker; Jianping Weng
Journal:  J Diabetes Sci Technol       Date:  2016-11-27

3.  Using a Cageside Device for Testing Glycosylated Hemoglobin in Cynomolgus Macaques (Macaca fascicularis).

Authors:  Jessica M Johnston; Jolaine M Wilson; Abigail L Smith; John T Farrar; Michael J Kallan; Christin L Veeder
Journal:  J Am Assoc Lab Anim Sci       Date:  2017-01-01       Impact factor: 1.232

4.  Effects of Food Label Use on Diet Quality and Glycemic Control Among Latinos With Type 2 Diabetes in a Community Health Worker-Supported Intervention.

Authors:  Grace Kollannoor-Samuel; Fatma M Shebl; Sofia Segura-Pérez; Jyoti Chhabra; Sonia Vega-López; Rafael Pérez-Escamilla
Journal:  Am J Public Health       Date:  2016-04-14       Impact factor: 9.308

5.  Assessment of a new point-of-care system for detection of prostate specific antigen.

Authors:  Steffen Rausch; Joerg Hennenlotter; Josef Wiesenreiter; Andrea Hohneder; Julian Heinkele; Christian Schwentner; Arnulf Stenzl; Tilman Todenhöfer
Journal:  BMC Urol       Date:  2016-01-19       Impact factor: 2.264

6.  Community-based diagnosis of non-communicable diseases and their risk factors in rural and urban Haiti: a cross-sectional prevalence study.

Authors:  Vincent DeGennaro Jr; Stuart Malcolm; Lindsay Crompton; Krishna Vaddiparti; Lazarus K Mramba; Catherine Striley; Linda Cottler; Kellee Taylor; Robert Leverence
Journal:  BMJ Open       Date:  2018-04-20       Impact factor: 2.692

7.  Selecting an A1C Point-of-Care Instrument.

Authors:  Heather P Whitley; Ee Vonn Yong; Casey Rasinen
Journal:  Diabetes Spectr       Date:  2015-08

8.  Meeting individualized glycemic targets in primary care patients with type 2 diabetes in Spain.

Authors:  I Miñambres; J J Mediavilla; J Sarroca; A Pérez
Journal:  BMC Endocr Disord       Date:  2016-02-17       Impact factor: 2.763

9.  Performance of Point-of-Care Testing Compared with the Standard Laboratory Diagnostic Test in the Measurement of HbA1c in Indonesian Diabetic and Nondiabetic Subjects.

Authors:  Afiat Berbudi; Nofri Rahmadika; Adi Imam Tjahjadi; Rovina Ruslami
Journal:  J Diabetes Res       Date:  2020-07-09       Impact factor: 4.011

10.  The effects of cognitive behavioral therapy for insomnia in people with type 2 diabetes mellitus, pilot RCT part II: diabetes health outcomes.

Authors:  Mohammed M Alshehri; Shaima A Alothman; Aqeel M Alenazi; Jason L Rucker; Milind A Phadnis; John M Miles; Catherine F Siengsukon; Patricia M Kluding
Journal:  BMC Endocr Disord       Date:  2020-09-05       Impact factor: 2.763

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.