Affordable clinical gait analysis: an assessment of the marker tracking accuracy of a new low-cost optical 3D motion analysis system.

Bruce Carse1, Barry Meadows, Roy Bowers, Philip Rowe.   

Abstract

BACKGROUND: 3D motion analysis represents a method of collecting objective, accurate and repeatable gait data, however the high cost of equipment inhibits its widespread use in routine clinical practice.
OBJECTIVE: To determine the marker tracking accuracy of a new low-cost optical 3D motion analysis system.
DESIGN: Comparative between-system study.
SETTING: Clinical motion analysis laboratories.
METHODS: A rigid cluster of four reflective markers was used to compare a low-cost Optitrack 3D motion analysis system against two more expensive systems (Vicon 612 and Vicon MX). Accuracy was measured by comparing the mean vector magnitudes (between each combination of markers) for each system, and reliability was measured through the coefficients of variation (CV). Gaps in the marker trajectories, which are considered undesirable, were also counted.
RESULTS: In terms of accuracy, the largest disagreement between mean vector magnitudes for Optitrack and Vicon MX was 2.2%. The largest disagreement between Vicon 612 and Vicon MX was 2.1%. Regarding reliability, the mean CV was lowest in Vicon MX (0.3%) and similar in the Vicon 612 (2.5%) and Optitrack (2.3%) systems. The number of trajectory gaps for the Vicon MX, Vicon 612 and Optitrack systems were; zero, six and 11 respectively.
CONCLUSIONS: The Optitrack system provides a low-cost 3D motion analysis system that can offer marker tracking accuracy and reliability which is comparable with an older and still widely used system (Vicon 612). Further development work is required before Optitrack can be used for full 3D gait analysis by physiotherapists and other health professionals.
Copyright © 2013 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

Keywords:  3D motion capture; Gait analysis; Low-cost; Optical motion capture

Mesh:

Year:  2013        PMID: 23747027     DOI: 10.1016/j.physio.2013.03.001

Source DB:  PubMed          Journal:  Physiotherapy        ISSN: 0031-9406            Impact factor:   3.358


  29 in total

1.  Knee joint vibroarthrography of asymptomatic subjects during loaded flexion-extension movements.

Authors:  Rasmus Elbæk Andersen; Lars Arendt-Nielsen; Pascal Madeleine
Journal:  Med Biol Eng Comput       Date:  2018-06-21       Impact factor: 2.602

2.  Toe-out angle changes after total knee arthroplasty in patients with varus knee osteoarthritis.

Authors:  Masayuki Tazawa; Makoto Sohmiya; Naoki Wada; Irma Ruslina Defi; Kenji Shirakura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-22       Impact factor: 4.342

3.  Predicting athlete ground reaction forces and moments from motion capture.

Authors:  William R Johnson; Ajmal Mian; Cyril J Donnelly; David Lloyd; Jacqueline Alderson
Journal:  Med Biol Eng Comput       Date:  2018-03-17       Impact factor: 2.602

4.  Reliable sagittal plane kinematic gait assessments are feasible using low-cost webcam technology.

Authors:  Robert J Saner; Edward P Washabaugh; Chandramouli Krishnan
Journal:  Gait Posture       Date:  2017-04-30       Impact factor: 2.840

5.  Feasibility of a Simplified, Clinically Oriented, Three-dimensional Gait Analysis System for the Gait Evaluation of Stroke Patients.

Authors:  Masahiko Mukaino; Kei Ohtsuka; Kazuhiro Tsuchiyama; Fumihiro Matsuda; Keisuke Inagaki; Junya Yamada; Hiroki Tanikawa; Eiichi Saitoh
Journal:  Prog Rehabil Med       Date:  2016-07-15

6.  A semi-automatic toolbox for markerless effective semantic feature extraction.

Authors:  Vito Paolo Pastore; Matteo Moro; Francesca Odone
Journal:  Sci Rep       Date:  2022-07-13       Impact factor: 4.996

7.  Accuracy and repeatability of smartphone sensors for measuring shank-to-vertical angle.

Authors:  Brandon T Nguyen; Nick A Baicoianu; Darrin B Howell; Keshia M Peters; Katherine M Steele
Journal:  Prosthet Orthot Int       Date:  2020-04-21       Impact factor: 1.895

8.  A perceptual map for gait symmetry quantification and pathology detection.

Authors:  Antoine Moevus; Max Mignotte; Jacques A de Guise; Jean Meunier
Journal:  Biomed Eng Online       Date:  2015-10-29       Impact factor: 2.819

9.  Gait Biomechanics and Patient-Reported Function as Predictors of Response to a Hip Strengthening Exercise Intervention in Patients with Knee Osteoarthritis.

Authors:  Dylan Kobsar; Sean T Osis; Blayne A Hettinga; Reed Ferber
Journal:  PLoS One       Date:  2015-10-07       Impact factor: 3.240

10.  Assessment of Gait Therapy Effectiveness in Patients with Parkinson's Disease on the Basis of Three-Dimensional Movement Analysis.

Authors:  Elżbieta Mirek; Jadwiga Lubomira Kubica; Jadwiga Szymura; Szymon Pasiut; Monika Rudzińska; Wiesław Chwała
Journal:  Front Neurol       Date:  2016-06-27       Impact factor: 4.003

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.