Literature DB >> 23746991

On-line solid phase extraction-liquid chromatography, with emphasis on modern bioanalysis and miniaturized systems.

Magnus Rogeberg1, Helle Malerod, Hanne Roberg-Larsen, Cecilie Aass, Steven Ray Wilson.   

Abstract

On-line solid phase extraction (SPE)-liquid chromatography (LC) allows for automated, sensitive, precise and selective bioanalysis. It is a common feature in miniaturized- or nano LC systems, which are well suited for applications requiring high sensitivity and/or treatment of limited samples (laser micro-dissection samples, rare cancer stem cells, etc.). Traditionally, particles with reversed phase (RP) functional groups are used for the columns in SPE-LC systems. There is however an expanding diversity in SPE-LC combinations applied to meet today's bioanalytical challenges. Current online SPE-LC combinations employ, e.g. porous graphitic carbon (PGC) and hydrophilic interaction liquid chromatography (HILIC) materials for metabolomics and glycomics, restricted access media (RAM) columns coupled with nano LC for peptidomics, immunoaffinity trap columns for targeted proteomics and metal oxide affinity phases for phosphopeptide analysis. However, issues can arise when combining different phases in on-line SPE-LC, e.g. due to solvent incompatibilities between enrichment/separation principles and sample solvent requirements. Consequences can be low recovery and poor resolution, or need for additional instrumentation. On-line SPE-LC with very narrow columns (10-20 μm inner diameters) can be appropriate to obtain maximum sensitivity and information. In such highly miniaturized systems, non-particulate columns are arguably more suited (e.g. monolithic or porous layer open tubular (PLOT) columns) as e.g. hardware contributions resulting in extra column volumes are reduced. Basic SPE-LC systems can be configured/modified to perform quite complex analytical operations, and certain columns, configurations and hardware can improve robustness.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bioanalysis; Enrichment; Nano LC; On-line SPE–LC; Selectivity

Mesh:

Substances:

Year:  2013        PMID: 23746991     DOI: 10.1016/j.jpba.2013.05.006

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  15 in total

1.  Targeted quantification of lipid mediators in skeletal muscles using restricted access media-based trap-and-elute liquid chromatography-mass spectrometry.

Authors:  Zhiying Wang; Liangqiao Bian; Chenglin Mo; Maciej Kukula; Kevin A Schug; Marco Brotto
Journal:  Anal Chim Acta       Date:  2017-07-14       Impact factor: 6.558

2.  Highly automated nano-LC/MS-based approach for thousand cell-scale quantification of side chain-hydroxylated oxysterols.

Authors:  Hanne Roberg-Larsen; Kaja Lund; Tore Vehus; Nina Solberg; Caroline Vesterdal; Dorna Misaghian; Petter Angell Olsen; Stefan Krauss; Steven Ray Wilson; Elsa Lundanes
Journal:  J Lipid Res       Date:  2014-05-02       Impact factor: 5.922

3.  Accurate quantification of modified cyclic peptides without the need for authentic standards.

Authors:  Rosemary I Adaba; Greg Mann; Andrea Raab; Wael E Houssen; Andrew R McEwan; Louise Thomas; Jioji Tabudravu; James H Naismith; Marcel Jaspars
Journal:  Tetrahedron       Date:  2016-11-16       Impact factor: 2.457

4.  Systematic examination of protein extraction, proteolytic glycopeptide enrichment and MS/MS fragmentation techniques for site-specific profiling of human milk N-glycoproteins.

Authors:  Bum Jin Kim; David C Dallas
Journal:  Talanta       Date:  2020-10-27       Impact factor: 6.057

5.  Integrated enzyme reactor and high resolving chromatography in "sub-chip" dimensions for sensitive protein mass spectrometry.

Authors:  Hanne Kolsrud Hustoft; Ole Kristian Brandtzaeg; Magnus Rogeberg; Dorna Misaghian; Silje Bøen Torsetnes; Tyge Greibrokk; Léon Reubsaet; Steven Ray Wilson; Elsa Lundanes
Journal:  Sci Rep       Date:  2013-12-16       Impact factor: 4.379

6.  Versatile, sensitive liquid chromatography mass spectrometry - Implementation of 10 μm OT columns suitable for small molecules, peptides and proteins.

Authors:  T Vehus; H Roberg-Larsen; J Waaler; S Aslaksen; S Krauss; S R Wilson; E Lundanes
Journal:  Sci Rep       Date:  2016-11-29       Impact factor: 4.379

Review 7.  Methacrylate Polymer Monoliths for Separation Applications.

Authors:  Robert J Groarke; Dermot Brabazon
Journal:  Materials (Basel)       Date:  2016-06-03       Impact factor: 3.623

8.  Proteomics tools reveal startlingly high amounts of oxytocin in plasma and serum.

Authors:  Ole Kristian Brandtzaeg; Elin Johnsen; Hanne Roberg-Larsen; Knut Fredrik Seip; Evan L MacLean; Laurence R Gesquiere; Siri Leknes; Elsa Lundanes; Steven Ray Wilson
Journal:  Sci Rep       Date:  2016-08-16       Impact factor: 4.379

9.  An optimised method for the proteomic profiling of full thickness human skin.

Authors:  Emily Bliss; Wendy E Heywood; Malika Benatti; Neil J Sebire; Kevin Mills
Journal:  Biol Proced Online       Date:  2016-07-21       Impact factor: 3.244

10.  Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring.

Authors:  Hanne Roberg-Larsen; Silvija Abele; Deniz Demir; Diana Dzabijeva; Sunniva F Amundsen; Steven R Wilson; Vadims Bartkevics; Elsa Lundanes
Journal:  Front Chem       Date:  2017-08-28       Impact factor: 5.221

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.