AIM: To evaluate the functional differences between the 2 liver lobes in non-cirrhotic patients by using computed tomography/(99m)Tc-galactosyl human serum albumin (CT/(99m)Tc-GSA) single-photon emission computed tomography (SPECT) fusion images. METHODS: Between December 2008 and March 2012, 264 non-cirrhotic patients underwent preoperative liver function assessment using CT/(99m)Tc-GSA SPECT fusion images. Of these, 30 patients, in whom the influence of a tumor on the liver parenchyma was estimated to be negligible, were selected. Specifically, the selected patients were required to meet either of the following criteria: (1) the presence of an extrahepatic tumor; or (2) presence of a single small intrahepatic tumor. These 30 patients were retrospectively analyzed to calculate the percentage volume (%Volume) and the percentage function (%Function) of each lobe. The ratio between the %Function and %Volume (function-to-volume ratio) of each lobe was also calculated, and the ratios were compared between the 2 lobes. Furthermore, the correlations between the function-to-volume ratio and each of 2 liver parameters [lobe volume and diameter ratio of the left portal vein to the right portal vein (LPV-to-RPV diameter ratio)] were investigated. RESULTS: The median values of %Volume and %Function were 62.6% and 67.1% in the right lobe, with %Function being significantly higher than %Volume (P < 0.01). The median values of %Volume and %Function were 31.0% and 28.7% in the left lobe, with %Function being significantly lower than %Volume (P < 0.01). The function-to-volume ratios of the right lobe (1.04-1.14) were significantly higher than those of the left lobe (0.74-0.99) (P < 0.01). The function-to-volume ratio showed no significant correlation between the lobe volume in either lobe. In contrast, the function-to-volume ratio showed significant correlations with the LPV-to-RPV diameter ratio in both lobes (right lobe: negative correlation, r s = -0.37, P = 0.048; left lobe: positive correlation, r s = 0.71, P < 0.001). The function-to-volume ratio in the left lobe tended to be higher, and that in the right lobe tended to be lower, in accordance with the increase in the LPV-to-RPV diameter ratio. CONCLUSION: CT/(99m)Tc-GSA SPECT fusion images demonstrated that the function of the left lobe was significantly decreased compared with that of the right lobe in non-cirrhotic livers.
AIM: To evaluate the functional differences between the 2 liver lobes in non-cirrhotic patients by using computed tomography/(99m)Tc-galactosyl human serum albumin (CT/(99m)Tc-GSA) single-photon emission computed tomography (SPECT) fusion images. METHODS: Between December 2008 and March 2012, 264 non-cirrhotic patients underwent preoperative liver function assessment using CT/(99m)Tc-GSA SPECT fusion images. Of these, 30 patients, in whom the influence of a tumor on the liver parenchyma was estimated to be negligible, were selected. Specifically, the selected patients were required to meet either of the following criteria: (1) the presence of an extrahepatic tumor; or (2) presence of a single small intrahepatic tumor. These 30 patients were retrospectively analyzed to calculate the percentage volume (%Volume) and the percentage function (%Function) of each lobe. The ratio between the %Function and %Volume (function-to-volume ratio) of each lobe was also calculated, and the ratios were compared between the 2 lobes. Furthermore, the correlations between the function-to-volume ratio and each of 2 liver parameters [lobe volume and diameter ratio of the left portal vein to the right portal vein (LPV-to-RPV diameter ratio)] were investigated. RESULTS: The median values of %Volume and %Function were 62.6% and 67.1% in the right lobe, with %Function being significantly higher than %Volume (P < 0.01). The median values of %Volume and %Function were 31.0% and 28.7% in the left lobe, with %Function being significantly lower than %Volume (P < 0.01). The function-to-volume ratios of the right lobe (1.04-1.14) were significantly higher than those of the left lobe (0.74-0.99) (P < 0.01). The function-to-volume ratio showed no significant correlation between the lobe volume in either lobe. In contrast, the function-to-volume ratio showed significant correlations with the LPV-to-RPV diameter ratio in both lobes (right lobe: negative correlation, r s = -0.37, P = 0.048; left lobe: positive correlation, r s = 0.71, P < 0.001). The function-to-volume ratio in the left lobe tended to be higher, and that in the right lobe tended to be lower, in accordance with the increase in the LPV-to-RPV diameter ratio. CONCLUSION: CT/(99m)Tc-GSA SPECT fusion images demonstrated that the function of the left lobe was significantly decreased compared with that of the right lobe in non-cirrhotic livers.
Authors: Y Yumoto; T Yagi; S Sato; K Nouso; Y Kobayashi; M Ohmoto; E Yumoto; I Nagaya; H Nakatsukasa Journal: Br J Surg Date: 2010-06 Impact factor: 6.939
Authors: Wilmar de Graaf; Krijn P van Lienden; Sander Dinant; Joris J T H Roelofs; Olivier R C Busch; Dirk J Gouma; Roelof J Bennink; Thomas M van Gulik Journal: J Gastrointest Surg Date: 2010-02 Impact factor: 3.452
Authors: Carolina Río Bártulos; Karin Senk; Mona Schumacher; Jan Plath; Nico Kaiser; Ragnar Bade; Jan Woetzel; Philipp Wiggermann Journal: Front Med (Lausanne) Date: 2022-04-06
Authors: Carolina Río Bártulos; Karin Senk; Ragnar Bade; Mona Schumacher; Jan Plath; Nico Kaiser; Isabel Wiesinger; Sylvia Thurn; Christian Stroszczynski; Abdelouahed El Mountassir; Mathis Planert; Jan Woetzel; Philipp Wiggermann Journal: Diagnostics (Basel) Date: 2022-07-20
Authors: Andrea Ferrigno; Giuseppina Palladini; Alberto Bianchi; Vittoria Rizzo; Laura G Di Pasqua; Stefano Perlini; Plinio Richelmi; Mariapia Vairetti Journal: Biomed Res Int Date: 2014-06-12 Impact factor: 3.411