Literature DB >> 23742176

Evaluation of correlation between aortic elastic parameters and atrial electromechanical abnormalities in hypertensive patients.

Omer Sen1, Gulcan Abali, Bunyamin Yavuz, Mutafa Kemal Batur.   

Abstract

OBJECTIVES: Arterial hypertension leads to instability and heterogeneity in atrial conduction by these hemodynamic and morphological changes in heart and aorta. These changes can be evaluated by transthoracic echocardiography. The aim of this study was to evaluate the correlation of aortic elastic parameters and atrial electromechanical delay (AEMD) parameters in patients with hypertension.
METHODS: Eighty-one hypertensive patients and 55 control subjects were included in the study. All subjects underwent transthoracic echocardiography for detecting aortic elastic parameters and AEMD parameters.
RESULTS: There was no difference between HT and control groups regarding age and gender. Aortic strain (8.1 ± 4.3% vs. 10.3 ± 5.1%, P = 0.008) and aortic distensibility (0.35 ± 0.18 cm(2) /dyn vs. 0.45 ± 0.23 cm(2) /dyn, P = 0.003) were decreased in hypertensive patients than in controls. Intra-left AEMD (25.5 ± 7.3 vs. 21.8 ± 9.2 P < 0.009) was significantly higher in hypertensive patients compared to control subjects. No statistically significant difference was found in intra-right AEMD and inter-AEMD between the groups. There was a positive significant moderate correlation between aortic strain and intra-left AEMD (r = 0.501, P < 0.001).
CONCLUSIONS: This study demonstrated that intra-left AEMD was increased in hypertensive patients and aortic elastic parameters was correlated with intra-left AEMD. These findings may be related to similar structural and functional changes in heart and aorta in hypertension.
© 2013, Wiley Periodicals, Inc.

Entities:  

Keywords:  aortic strain; doppler tissue imaging; electromechanical delay; hypertension

Mesh:

Year:  2013        PMID: 23742176     DOI: 10.1111/echo.12257

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  2 in total

1.  Lead exposure is related to impairment of aortic elasticity parameters.

Authors:  Mujgan T Ozturk; Bunyamin Yavuz; Selcuk Ozkan; Mehmet Ayturk; Tolga Akkan; Esin Ozkan; Engin Tutkun; Ömer H Yılmaz
Journal:  J Clin Hypertens (Greenwich)       Date:  2014-09-27       Impact factor: 3.738

2.  Assessment of ventriculo-vascular properties in repaired coarctation using cardiac magnetic resonance-derived aortic, left atrial and left ventricular strain.

Authors:  Quanliang Shang; Samir Sarikouch; Shivani Patel; Andreas Schuster; Michael Steinmetz; Phalla Ou; David A Danford; Philipp Beerbaum; Shelby Kutty
Journal:  Eur Radiol       Date:  2016-05-23       Impact factor: 5.315

  2 in total