Literature DB >> 23740342

Analysis of square-wave bouts to verify VO2max.

D Sedgeman1, L Dalleck, I E Clark, N Jamnick, R W Pettitt.   

Abstract

Submaximal and supramaximal square-wave bouts have been reported to consistently verify 'true' VO2max. Although a direct comparison between both protocols exists, knowledge on the statistical consistency between the protocols using the same group of participants is lacking. The purpose of this study was to conduct an analysis of the submaximal and supramaximal verification bout performed shortly subsequent to a graded exercise test (GXT). On 2 separate occasions, 6 males and 7 females (age: 29±9 years) completed a GXT protocol and an exhaustive, square-wave bout at either end-GXT power minus 2-stages or 105% end-GXT power. No differences (p>0.05) in VO2max were observed between the GXT and square-wave bouts. The typical error (ml/kg/min) for submaximal (1.09) and supramaximal (1.04) trials was similar. Likewise, similar relative measures of consistency were observed for the submaximal (ICC α=0.97, CV=2.4%) and supramaximal trials (ICC α=0.95, CV=2.3%). For a GXT lasting ~10-12 min, the submaximal or supramaximal protocols appear to be equally effective. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2013        PMID: 23740342     DOI: 10.1055/s-0033-1341436

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  11 in total

1.  The effect of posture on maximal oxygen uptake in active healthy individuals.

Authors:  Hayley T Dillon; Christophe Dausin; Guido Claessen; Anniina Lindqvist; Amy Mitchell; Leah Wright; Rik Willems; André La Gerche; Erin J Howden
Journal:  Eur J Appl Physiol       Date:  2021-02-27       Impact factor: 3.078

2.  Is a verification phase needed to determine [Formula: see text]O2max across fitness levels?

Authors:  Seth F McCarthy; Jarryd M P Leung; Tom J Hazell
Journal:  Eur J Appl Physiol       Date:  2021-01-02       Impact factor: 3.078

3.  The efficacy of a discontinuous graded exercise test in measuring peak oxygen uptake in children aged 8 to 10 years.

Authors:  D Lambrick; J Jakeman; R Grigg; S Kaufmann; J Faulkner
Journal:  Biol Sport       Date:  2016-12-01       Impact factor: 2.806

4.  Measurement of a True [Formula: see text]O2max during a Ramp Incremental Test Is Not Confirmed by a Verification Phase.

Authors:  Juan M Murias; Silvia Pogliaghi; Donald H Paterson
Journal:  Front Physiol       Date:  2018-02-27       Impact factor: 4.566

5.  Effect of intensive prior exercise on muscle fiber activation, oxygen uptake kinetics, and oxygen uptake plateau occurrence.

Authors:  Max Niemeyer; Renate Leithäuser; Ralph Beneke
Journal:  Eur J Appl Physiol       Date:  2020-06-27       Impact factor: 3.078

6.  Supra-Versus Submaximal Cycle Ergometer Verification of VO2max in Males and Females.

Authors:  Brandon J Sawyer; Nicholas McMahon; Kirsten L Thornhill; Brett R Baughman; Jenny M Mahoney; Kai L Pattison; Kaitlin A Freeberg; Ryan T Botts
Journal:  Sports (Basel)       Date:  2020-12-12

7.  Verification-phase tests show low reliability and add little value in determining [Formula: see text]O2max in young trained adults.

Authors:  Jonathan Wagner; Max Niemeyer; Denis Infanger; Timo Hinrichs; Clement Guerra; Christopher Klenk; Karsten Königstein; Christian Cajochen; Arno Schmidt-Trucksäss; Raphael Knaier
Journal:  PLoS One       Date:  2021-01-11       Impact factor: 3.240

8.  Assessing the ability of the Fitbit Charge 2 to accurately predict VO2max.

Authors:  Kaitlin A Freeberg; Brett R Baughman; Ted Vickey; Jeff A Sullivan; Brandon J Sawyer
Journal:  Mhealth       Date:  2019-09-23

Review 9.  The Maximal Oxygen Uptake Verification Phase: a Light at the End of the Tunnel?

Authors:  Gustavo Z Schaun
Journal:  Sports Med Open       Date:  2017-12-08

Review 10.  The Oxygen Uptake Plateau-A Critical Review of the Frequently Misunderstood Phenomenon.

Authors:  Max Niemeyer; Raphael Knaier; Ralph Beneke
Journal:  Sports Med       Date:  2021-04-29       Impact factor: 11.136

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.