Literature DB >> 23739854

Spectrophotometric analysis of crown discoloration induced by MTA- and ZnOE-based sealers.

Konstantinos Ioannidis1, Ilias Mistakidis, Panagiotis Beltes, Vassilis Karagiannis.   

Abstract

UNLABELLED: Crown discoloration can be induced by root canal sealer remnants following root canal treatment.
OBJECTIVE: The aim of this study was to evaluate chromatic alterations in human tooth crowns induced by a Mineral Trioxide Aggregate-based sealer (MTA Fillapex®) and a commonly used ZnOE-based sealer (Roth-811). The tested null hypothesis was that the application of the materials did not induce clinically perceptible crown discoloration (Ho: CIE color difference ΔE<3.7).
MATERIAL AND METHODS: Forty five fully developed, intact, mandibular third molars were sectioned 1 mm below the cemento-enamel junction. The pulp chambers were chemomechanically debrided via the cervical access. The specimens were randomly assigned into three groups Group 1: MTA Fillapex, Group 2: Roth 811, Group 3: Negative control (unfilled) and immersed in individually marked vials containing distilled water up to the cervix (37±1°C). The spectral reflectance lines were recorded by utilizing a UV-VIS spectrophotometer equipped with integration sphere in the visual spectrum at baseline, 1 week, 1 and 3 months after material placement. Data were transformed into values of the CIE L*a*b* color system and the corresponding ΔE values were calculated. Statistical analysis was performed using two-way mixed ANOVA models, at p=0.05 level of significance.
RESULTS: A statistically significant increase in a* and b* chromatic parameters of the MTA Fillapex Group was measured. However, ΔE values did not exceed the human eye perceptibility threshold (set at ΔE<3.7) during the experimental period (ΔEt3=2.88). In Roth-811 Group, a statistically significant decrease in L* and a statistically significant increase in a* and b* chromatic parameters was measured, during all observation periods. Resultant ΔE values exceeded the human eye perceptibility threshold after 1 week (ΔEt1=5.65).
CONCLUSIONS: Application of MTA Fillapex in tooth crowns resulted in minimal color alterations, while Roth 811 induced severe discoloration, in vitro. It could be suggested that, in terms of aesthetics, the use of MTA Fillapex appears to be favorable.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23739854      PMCID: PMC3881871          DOI: 10.1590/1678-7757201302254

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


INTRODUCTION

Poor aesthetic appearance of endodontically treated teeth remains a challenging issue in clinical dentistry even nowadays. Interestingly, it has been reported that poor aesthetic appearance of a treated tooth significantly affects the patients' quality of life[10]. A major etiological factor for the occurrence of local intrinsic staining, especially in the cervical and middle third of the crown, is the presence of root canal filling materials in contact with the coronal dentin of the pulp chamber[16,17]. In the long-term, core materials and sealers interact with dentin. Any change to the optical and chromatic properties of the dentinal structure is likely to cause an alteration in the outward appearance of the crown caused by its light transmitting and reflecting properties[16,17]. Apart from thorough pulp chamber debridement, a reduction of the coronal aspect of the root canal filling below the clinical cervix is required for the prevention of sealer-induced crown discoloration in the anterior aesthetic zone. However, sealer remnants cannot be always thoroughly removed from the pulp chamber and sometimes are present due to iatrogenic inadequate manipulations. Despite the improvement of physicochemical, biomechanical and biological properties of endodontic sealers, the appearance of coronal discoloration is still evident in daily practice. Several laboratory studies have shown that some categories of sealers including ZnOE and epoxy-based sealers are capable of inducing moderate to severe crown discoloration[17,24,25,29]. In endodontics, ZnOE sealers are used in clinical practice for many decades and are regarded as a gold standard in several laboratory and clinical studies. These materials are regarded to be clinically satisfactory, providing reasonable seal in the root canal system[13]. However, after setting reaction, the formation of a weak porous mass leads to dissolution in contact with tissue fluids[8]. Due to gradual hydrolysis, the release of eugenol leads to long-lasting cytotoxicity and additional potential for sensitization[6]. Recently, Mineral Trioxide Aggregate (MTA) Fillapex® was introduced as a new generation MTA-based sealer. The main concept for the development of MTA-based sealers is the exploitation of the physical and biological properties of MTA such as bioactivity[12], biocompatibility[21] and hard tissue conductivity[22]. A developing amount of research data is becoming available upon MTA Fillapex, with regard to its physical and biological properties[2,13,14,23,26]. Considering the increasing demands for aesthetics, biomaterials should be chromatically stable, present optical properties similar to dental structures and not exert staining effects to hard dental tissues[17]. Recent reports showed that both White and Gray MTA formulations are capable of inducing tooth discoloration[4,5]. From that perceptive, it is mandatory for every new MTA-based material to be tested in terms of aesthetic and color objectives. Currently, there are no available studies investigating the potential of MTA Fillapex to induce color alterations to dental tissues. The aim of this study was to evaluate the chromatic alterations in human tooth crowns induced by MTA Fillapex and Roth 811 root canal sealer. The null-hypothesis (Ho) to be tested was that the application of the materials did not induce clinically perceptible crown discoloration (Ho: CIE color difference ΔE<3.7)[19].

Preparation of teeth

Forty five freshly extracted, fully developed, impacted and semi-impacted mandibular third molars free of cracks, fractures, caries, abrasions and discoloration due to systemic intrinsic causes were collected, according to the guidelines of good clinical practice (Department of Oral and Maxillofacial Surgery, School of Dentistry, Ethical Committee, Aristotle University of Thessaloniki, Greece). Soft tissue was removed and the teeth were sectioned in the coronal third of the root complex, 1 mm below the buccal cemento-enamel junction. Sectioning was performed with the aid of a low-speed diamond-edge rotary saw microtome (Leica RM2255, Leica, Wetzlar, Germany). Access cavity preparation was not performed. Pulps were extirpated with a dental spoon and the internal axial walls of the pulp chambers were chemo-mechanically debrided with Hedstrom files (No. #60-80) and 10 ml of sodium hypochlorite (2.5% w/w), through the apical access. Gentle reaming of the internal axial walls was performed through all directions. Between every file sequence, the pulp chamber was irrigated with 2 ml of sodium hypochlorite (2.5% w/w) (3 file changes x 2 ml=6 ml). A final rinse with 4 ml of sodium hypochlorite (2.5% w/w) was performed at the end of the debridement. The pulp chambers of the specimens were finally washed with 5 ml sterile saline to remove sodium hypochlorite remnants. At the beginning of the experimental period, all crowns were transferred and stored in individually marked polyethlylene tubes containing distilled water up to the cervix of the crown in an incubator at 37±1º C. The teeth (N=45) were randomly assigned in one experimental (n=15), one positive (n=15) and one negative control group (n=15). The materials to be evaluated were MTA Fillapex (Angelus, Londrina, Brazil) (Group 1) and a ZnOE based sealer, Roth 811 (Roth's International, Chicago, IL) (Group 2) (Figure 1). The sealers were mixed and prepared according to the manufacturers' instructions and were placed into the pulp chambers via the cervical access. A finger plugger was used to coat the internal axial walls with the sealers. The apical access was sealed with a thin layer of glass-ionomer cement (Ketac Cem Aplicap, 3M, Espe, Germany) in order to address microleakage and sealers solubility. Negative controls (Group 3) were only instrumented and remained unfilled.
Figure 1

Study groups 1-3

GroupSample size (n)Materials under studyManufacturerComposition
Group 115MTA FillapexAngelus, Londrina, Brazilresins (salicylate, diluting, natural), bismuth trioxide, nanoparticulated silica, mineral trioxide aggregate, pigments
Group 2 (positive control)15Roth 811Roth's International, Chicago, ILPowder: Zinc oxide, bismouth bicarbonate, barium sulfate, dehydrated tetraboric sodium Liquid: Chemically pure eugenol
Group 3(negative control)15Unfilled  
Study groups 1-3

Measurement of crown chromatic alterations

A double-beam UV-Vis spectrophotometer equipped with integrating sphere was used (UV-2401PC, Shimadzu Corporation, Kyoto, Japan) and a standardized mounting system was developed, utilizing a previously validated experimental model[17]. Standard D65 illumination was chosen (Commission Internationale de L'Eclairage 1978), as it corresponds approximately to the spectrum of midday daylight in Western/Northern Europe. The spectrophotometer was linked to a computer, which recorded the spectral reflectance curves of the crowns, in visual spectrum (380-780 nm). The obtained spectral curves in visual spectrum (380-780 nm) were transformed into L*, a* and b* values of the perceptually uniform CIE L*, a*, b* color space using a specialized computer software (Color Analysis UV-2401PC). L* values describe lightness, which range from black (0) to white (100), while a* values represent red (+80a*) to green (-80a*), and b* values represent yellow (+80b*) to blue (-80b*) color variations. Total color differences (ΔE) were calculated according to the equation: ΔE= [(Li-L0*)2+(ai-a0*)2+(bi-b0*)2]1/2 The proposed acceptance for color matching adopted in this study was at 3.7 ΔE units (perceptibility threshold), beyond which the differences are clinically perceptible[19]. In dental science, when ΔE values are less than 1 unit, then color match occurs and any color differences cannot be identified by independent observers in vitro[27]. However, color determination in clinical dentistry may become complicated by adjacent anatomic structures and lighting conditions. As a result, the proposed acceptance for color matching in dentistry has been set to 3.7 units (perceptibility threshold), beyond which differences are clinically visible[19]. A standardized mounting system was developed for the customization and the reproducibility of the crown's position. The cylindrical inner frame (diameter=2 cm, inner height=0.2 cm) of the black bakelite sample assembly that the spectrophotometer was equipped with, was filled with black, non-polychromatic, thermo-plasticized silicone. The lingual surface of each crown was fixed within the silicone mass during its setting phase in order to construct individualized specimen carriers. The same individualized, silicone carrier for each specimen was used for measurements in all time intervals. The specimens were positioned in the in the circular opening of the aperture mask of the integrating sphere with the aid of an aligning system in order to ensure the reproducibility of the measured surface. The dimensions of the polychromatic beam that illuminated the sample were 7x7 mm; thus the majority of the cervix and the crown surface was exposed and measured. The color appearance of the buccal surfaces of the crowns was measured in order to simulate their clinical appearance. Measurements were carried out by the same operator (I.M.) and at ambient temperature of 23±1º C. The spectrophotometer was calibrated at each time interval using BaSO4 reference. Measurements were performed prior to the placement of the materials (baseline: t0) and consecutively 1 week (t1), 1 month (t2) and 3 months (t3) after sealer placement. All measurements were repeated twice and averaged. If the total color difference (ΔE) between 2 measurements taken in a row exceeded the threshold of 1 DE unit, new measurements were obtained. At the end of the 3rd month, three crowns of the experimental groups were randomly selected and longitudinally sectioned vertically to the middle of their mesio-distal dimension, on a bucco-lingual aspect, with the aid of a low-speed diamond-edge rotary saw microtome (Leica RM2255, Leica, Wetzlar, Germany). Digital images of the sectioned crown specimens were taken, in day-light conditions (Macro-Lense 100 mm, Canon EOS 1000D, Tokyo, Japan).

Statistical analysis

Sample size was calculated after power analysis based on the results of a pilot study, according to the equation n=2(z1- + z)2 σ2 {1+(m - 1)ρ}/mΔ 2 with ρ=0.5, m=4 (repeated measurements), σ2=4, Δ=2.2, alpha=0.05, power=0.8 (the chosen value of Δ was greater than the observed one in order to be close to the 3.7 threshold value and analogously done for the σ 2 )[17]. Accordingly the sample size to each group was calculated near to n=12 specimens per group. In case of drop out during the experimental period, 3 specimens were added in each group (n=15). Two-way ANOVA with repeated measurements was used for data analysis of the values of CIE L*, a*, b* chromatic parameters and the total color differences (ΔE). The significant effects and interactions of the experimental factors were investigated with pairwise between-group and within-group comparisons, which were conducted with Bonferroni's method. The overall analysis was performed with SPSS software (version 16.0, SPSS Inc., Chicago, Ill, USA). The level of statistical significance was set at p<0.05.

RESULTS

Tables 1 and 2 present the mean L*, a*, b* and ΔE values of all groups, in all time intervals respectively. With regard to L*, a* and b* parameters, MTA Fillapex caused a statistically significant increase in a* (Δa*to-t3=1.043, p<0.001) and b* (Δb* to-t3=2.292, p<0.001) values. L* values remained stable. However, resultant ΔE values indicate that MTA Fillapex induced overall color changes below the human perceptibility threshold, ranging between 2.12-2.88 units. Roth 811 induced severe color changes exceeding the perceptibility threshold from the 1st week of evaluation (ΔE=5.65). A statistically significant increase in a* (Δa*to-t3=-3,335, p<0.001) and b* (Δb* to-t3=-4,014, p<0.001) values was observed, while L* values statistically decreased (ΔL*to-t3=4,926, p<0.001). In Group 3, L*, a*, b* values remained stable in all time intervals.
Table 1

CIE L*, a*, b* mean standard deviation values of Groups 1-3, in all experimental periods

  baseline1st week1st month3rd month
 (CIE) L* parameter  
 
  
GroupsnL0L1L2L3
MTA Fillapex1584.95(3.14)85.36(2.54)84.35(3.10)84.91(2.61)
Roth 8111584.21(1.98)81.89(1.18)79.38(1.82)79.28(1.71)
Negative control1584.55(2.22)84.77(2.26)84.48(2.34)84.55(2.17)
      
      
  baseline1st week1st month3rd month
 (CIE) a* parameter  
 
  
Groupsna0a1a2a3
MTA Fillapex150.15(0.68)0.57(0.67)0.77(0.68)1.19(0.65)
Roth 811150.01(0.79)2.03(0.82)2.71(1.00)3.34(1.05)
Negative control150.42(0.74)0.39(0.66)0.38(0.73)0.41(0.73)
      
      
  baseline1st week1st month3rd month
 (CIE) b* parameter  
 
  
Groupsnb0b1b2b3
MTA Fillapex1521.60(2.82)23.36(2.21)22.64(2.74)23.89(2.35)
Roth 8111521.26(2.33)25.67(2.36)24.76(2.72)25.28(2.89)
Negative control1520.62(3.11)20.33(2.89)20.49(2.94)20.57(3.07)

Within-group comparisons: a statistically significant differences when compared to t0, b when compared to t1, c when compared to t2, d when compared to t3

Between-group comparisons: a statistically significant differences when compared to Fillapex, B when compared to Roth 811

Table 2

Mean standard deviation ΔE values of Groups 1-3 in all experimental periods

  1st week1st month3rd month
Groupsn(ΔΕ1)(ΔΕ2)(ΔΕ3)
MTA Fillapex152.13(1.18)2.12(0.72)2.88(1.49)
Roth 811155.65(2.34)6.70(2.68)7.37(3.02)
Negative control150.51(0.37)0.61(0.30)0.51(0.20)

Within-group comparisons: a statistically significant differences when compared to ΔΕ1, b when compared to ΔΕ2, c when compared to ΔΕ3

Between-group comparisons: A statistically significant differences when compared to MTA Fillapex, B when compared to Roth 811

CIE L*, a*, b* mean standard deviation values of Groups 1-3, in all experimental periods Within-group comparisons: a statistically significant differences when compared to t0, b when compared to t1, c when compared to t2, d when compared to t3 Between-group comparisons: a statistically significant differences when compared to Fillapex, B when compared to Roth 811 Mean standard deviation ΔE values of Groups 1-3 in all experimental periods Within-group comparisons: a statistically significant differences when compared to ΔΕ1, b when compared to ΔΕ2, c when compared to ΔΕ3 Between-group comparisons: A statistically significant differences when compared to MTA Fillapex, B when compared to Roth 811 The macroscopic examination of the sectioned specimens of Group 1 (MTA Fillapex) showed stability of sealer color within its mass and absence of dentinal staining (Figure 2). On the contrary, in Group 2 (Roth 811) the set sealer displayed a granular, grayish appearance. Dark orange dentinal staining accompanied by varying leaching within tubules was evident, in areas where sealer remnants were in contact with the axial walls of the pulp chamber (Figure 3).
Figure 2

Appearance of Group 1 (MTA Fillapex) after 3 months. Color stability of MTA Fillapex sealer within its mass and absence of dentinal staining

Figure 3

Appearance of Group 2 (Roth 811) after 3 months. Granular, grayish appearance of Roth 811 sealer and dark orange dentinal staining accompanied by varying leaching within tubules

Appearance of Group 1 (MTA Fillapex) after 3 months. Color stability of MTA Fillapex sealer within its mass and absence of dentinal staining Appearance of Group 2 (Roth 811) after 3 months. Granular, grayish appearance of Roth 811 sealer and dark orange dentinal staining accompanied by varying leaching within tubules

DISCUSSION

MTA Fillapex is a newly developed MTA-based root canal sealer. According to the manufacturer, its composition after mixture is basically MTA particles incorporated in a matrix of salicylate resin, natural resin, bismuth and silica. Other proposed MTA-based sealers consist of MTA with other additives, including HEMA, TEGDMA resins (lc-MTA) and water-soluble polymers (ProRoot-Endo sealer)[7,11]. Recent data reported that MTA Fillapex presents acceptable physical properties, antibacterial properties and intracanal resistance to dislodgement similar to AH Plus[2,23]. The sealer presents increased cytotoxicity during the setting reaction which decreases over time[26]. After setting, the sealer is capable of retaining alkaline pH levels due to calcium release, and presents bioactivity stimulating hydroxyapatite crystal nucleation in human osteoblast-like cell cultures[26] and mineralization in connective tissue[14]. The rational for organizing this research study was the increasing publication of case reports, in which the discoloring effect of MTA has been reported. Both Gray and White MTA repair materials were capable of inducing coronal discoloration, when applied in cases of root and furcal perforation, pulpotomy and pulp revascularization procedures[4,5]. In addition, two recent laboratory studies confirmed the previous clinical observations with the aid of instrumental colorimetry[1] and visual spectrophotometry[18]. It has been proposed that metal oxides, such as iron and manganese, could be responsible for the discoloring effects of Gray MTA[18]. Moreover, recent data have shown that the discoloring effects of White MTA have been attributed to its progressive mass darkening due the presence of reduced black crystals of bismuth atoms under light conditions[28]. This laboratory study is the first to report tooth color alterations induced by MTA Fillapex, utilizing the methodology of visual spectrophotometry. Within the limitations of this experimental study, in acceptance of the null hypothesis, MTA Fillapex did not induce clinically perceptible crown discoloration. In rejection of the null hypothesis, Roth 811 induced fast and severe discoloration and exceeded the perceptibility threshold 1 week after sealer placement. The results of this study indicated that the tested sealer had minimum potential to induce color alterations in human teeth in vitro, since the measured color alterations did not exceed the threshold of perceptibility set (ΔE<3.7). The descriptive analysis of the CIE L*, a*, b* chromatic parameters showed a statistically significant color change towards red and yellow after three months, while lightness was not affected. The macroscopic findings confirmed that the sealer did not present color changes within its mass, maintaining its yellowish color throughout the experimental period. Dentinal staining was not evident as well. The increase of CIE a* and b* values of the crowns from the first week of investigation may be attributed to alterations in specimens' optical properties due to the physical presence of the sealer in the internal dentinal surface. Roth 811 sealer induced fast and severe discoloration, which was clinically perceptible 1 week following sealer placement. The chromogenic potential of ZnOE sealers has been attributed to the unstable chemical bond between ZnO and eugenol. Even after the end of the setting reaction, eugenol release leads to self-oxidation and becomes darker with time. The results of this study are in complete accordance with results of previous studies[17,25,29]. Several methods have been proposed for the evaluation or measurement of sealer-induced discoloration, including visual technique and computer analysis of digital photos[24,25,29]. Inherent objectivity and standardization difficulties may be improved by the use of a spectrophotometer[15]. This methodology has been reported as accurate and reliable in dentistry for quantitative tooth color measurements[17,20]. A major advantage of visual spectrophotometry is that tooth color measurement is based on the measurement of spectral reflectance, which describes the total reflection of a sample in visual spectrum[17]. Random errors in this study were minimized by strict control of the environmental factors along with multiple measurements and averaging. One of the main limitations of instrumental color measurement, however, is posed by systematic errors that can be attributed to variations in instrument geometrical design, metamerism and calibration techniques[27]. The comparison of absolute tristimulus values found in that study with other studies is discouraged. Evaluation and comparison of total color differences (expressed by ΔE), however, is well documented and considered as safe since differential measurement is highly reproducible between instruments[9]. The results of this study are comparable to those of a previous study which was conducted utilizing the same methodology and under the same experimental conditions. After 3 months, non-perceptible total color differences (ΔE) of MTA Fillapex were similar to the ΔE values of Guttaflow (Roeko, Coltene, Whaledent Ltd., Germany) and Epiphany SE (Pentron Clinical Technologies, Wallingford, CT), indicating that they likewise exert minimal chromogenic effects[17]. The results of this study do not directly represent the in vivo tooth discoloration potential of root canal sealers in good clinical practice. In this laboratory study, the investigation of the discoloration potential of root canal sealers was based on the generation of a "worst case scenario" by leaving a significant amount of sealer in direct contact with the axial dentinal walls and several anatomical features of the pulp chamber[17]. However, the knowledge of the magnitude of the sealers' chromogenic potential indicates that thorough cleaning measures are essential to prevent discoloration postoperatively. Regardless of the minimal staining effects of new generation root canal sealers including MTA Fillapex, the clinician should always ensure thorough removal of sealer remnants. Apart from basic properties, such as biocompatibility and good sealing ability, it could be suggested that the chromogenic potential of sealers may also play an important role in selecting proper root canal filling materials.

CONCLUSION

Within the limitations of this experimental study, MTA Fillapex did not induce clinically perceptible crown discoloration. Roth 811 induced fast and severe discoloration and exceeded the perceptibility threshold 1 week after sealer placement. Although the incorporated MTA has proved chromogenic potential, MTA Fillapex posed minimal risk for potential staining effects. It could be suggested that, in terms of aesthetics, the use of MTA Fillapex appears to be favorable.
  29 in total

1.  In vitro longitudinal assessment of coronal discoloration from endodontic sealers.

Authors:  J R Parsons; R E Walton; L Ricks-Williamson
Journal:  J Endod       Date:  2001-11       Impact factor: 4.171

2.  Tissue reactions after subcutaneous and intraosseous implantation of mineral trioxide aggregate and ethoxybenzoic acid cement.

Authors:  T R Moretton; C E Brown; J J Legan; A H Kafrawy
Journal:  J Biomed Mater Res       Date:  2000-12-05

3.  Evaluation of solubility, disintegration, and dimensional alterations of a glass ionomer root canal sealer.

Authors:  Jacy Ribeiro Carvalho-Júnior; Luiz Fernando L Guimarães; Lourenço Correr-Sobrinho; Jesus D Pécora; Manoel D Sousa-Neto
Journal:  Braz Dent J       Date:  2003

4.  Spectrophotometric analysis of coronal discolouration induced by grey and white MTA.

Authors:  K Ioannidis; I Mistakidis; P Beltes; V Karagiannis
Journal:  Int Endod J       Date:  2012-07-24       Impact factor: 5.264

5.  Color stability of white mineral trioxide aggregate.

Authors:  Marta Vallés; Montserrat Mercadé; Fernando Duran-Sindreu; Jose Luis Bourdelande; Miguel Roig
Journal:  Clin Oral Investig       Date:  2012-07-20       Impact factor: 3.573

6.  Validation and spectrophotometric analysis of crown discoloration induced by root canal sealers.

Authors:  Konstantinos Ioannidis; Panagiotis Beltes; Theodor Lambrianidis; Dimitrios Kapagiannidis; Vassilis Karagiannis
Journal:  Clin Oral Investig       Date:  2012-09-30       Impact factor: 3.573

7.  Mineral trioxide aggregate-based endodontic sealer stimulates hydroxyapatite nucleation in human osteoblast-like cell culture.

Authors:  Loise Pedrosa Salles; Ana Lívia Gomes-Cornélio; Felipe Coutinho Guimarães; Bruno Schneider Herrera; Sonia Nair Bao; Carlos Rossa-Junior; Juliane Maria Guerreiro-Tanomaru; Mario Tanomaru-Filho
Journal:  J Endod       Date:  2012-04-06       Impact factor: 4.171

8.  Development of the foremost light-curable calcium-silicate MTA cement as root-end in oral surgery. Chemical-physical properties, bioactivity and biological behavior.

Authors:  Maria Giovanna Gandolfi; Paola Taddei; Francesco Siboni; Enrico Modena; Gabriela Ciapetti; Carlo Prati
Journal:  Dent Mater       Date:  2011-05-06       Impact factor: 5.304

9.  Sealability of MTA and calcium hydroxidecontaining sealers.

Authors:  João Eduardo Gomes-Filho; Jaqueline Viana Moreira; Simone Watanabe; Carolina Simonetti Lodi; Luciano Tavares Angelo Cintra; Eloi Dezan Junior; Pedro Felício Estrada Bernabé; Mauro Juvenal Nery; José Arlindo Otoboni Filho
Journal:  J Appl Oral Sci       Date:  2012 May-Jun       Impact factor: 2.698

10.  Effect of dentin bonding agent on the prevention of tooth discoloration produced by mineral trioxide aggregate.

Authors:  Majid Akbari; Armita Rouhani; Sadeq Samiee; Hamid Jafarzadeh
Journal:  Int J Dent       Date:  2011-11-03
View more
  11 in total

1.  In vitro investigations into the etiology of mineral trioxide tooth staining.

Authors:  Todd Berger; Adam Z Baratz; James L Gutmann
Journal:  J Conserv Dent       Date:  2014-11

Review 2.  Bioceramic-Based Root Canal Sealers: A Review.

Authors:  Afaf Al-Haddad; Zeti A Che Ab Aziz
Journal:  Int J Biomater       Date:  2016-05-03

3.  Tooth discoloration induced by a novel mineral trioxide aggregate-based root canal sealer.

Authors:  Dae-Sung Lee; Myung-Jin Lim; Yoorina Choi; Vinicius Rosa; Chan-Ui Hong; Kyung-San Min
Journal:  Eur J Dent       Date:  2016 Jul-Sep

Review 4.  Discoloration Potential of Endodontic Sealers: A Brief Review.

Authors:  Sohrab Tour Savadkouhi; Mahta Fazlyab
Journal:  Iran Endod J       Date:  2016

5.  A Comparative Chemical Study of Calcium Silicate-Containing and Epoxy Resin-Based Root Canal Sealers.

Authors:  Przemysław Reszka; Alicja Nowicka; Mariusz Lipski; Włodzimierz Dura; Agnieszka Droździk; Krzysztof Woźniak
Journal:  Biomed Res Int       Date:  2016-12-20       Impact factor: 3.411

6.  Tooth Discoloration Resulting from a Nano Zinc Oxide-Eugenol Sealer.

Authors:  Mina Zarei; Maryam Javidi; Marzieh Jafari; Maryam Gharechahi; Pedram Javidi; Maryam Shayani Rad
Journal:  Iran Endod J       Date:  2017

Review 7.  Genotoxicity, Bioactivity and Clinical Properties of Calcium Silicate Based Sealers: A Literature Review.

Authors:  Farnaz Jafari; Sanaz Jafari; Paria Etesamnia
Journal:  Iran Endod J       Date:  2017

8.  Effect of Nd:YAG and Diode Lasers on Apical Seal of Root Canals Filled with AH Plus and Mineral Trioxide Aggregate-Based Sealers.

Authors:  Elham Khoshbin; Zakiyeh Donyavi; Erfan Abbasi Atibeh; Shahin Kasraei; Rasoul Yousefimashouf; Ghodratollah Roshanaei; Faranak Amani
Journal:  J Dent (Tehran)       Date:  2018-01

9.  The Discoloration effect of White Mineral Trioxide Aggregate (WMTA), Calcium Enriched Mixture (CEM), and Portland Cement (PC) on Human Teeth.

Authors:  Amin Salem-Milani; Saeede Ghasemi; Saeed Rahimi; Amir Ardalan-Abdollahi; Mohammad Asghari-Jafarabadi
Journal:  J Clin Exp Dent       Date:  2017-12-01

10.  Prevention of coronal discoloration induced by root canal sealer remnants using Dentin Bonding agent: An in vitro study.

Authors:  Tan Peik Khim; Venukumar Sanggar; Tey Wei Shan; Koay Chong Peng; J Sylvia Western; Daniel Devaprakash Dicksit
Journal:  J Conserv Dent       Date:  2018 Sep-Oct
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.