Literature DB >> 2373812

Clinical and angiographic results of balloon-expandable intracoronary stents in right coronary artery stenoses.

M J Levine1, B M Leonard, J A Burke, I D Nash, R D Safian, D J Diver, D S Baim.   

Abstract

Balloon-expandable stents were placed successfully in 35 (95%) of 37 patients whose right coronary artery lesion was believed to have a poor short- or long-term prognosis with conventional balloon angioplasty because of prior restenosis or adverse lesion morphology. Quantitative angiography showed a reduction in stenosis diameter from 83 +/- 14% to 42 +/- 14% after conventional balloon dilation, with a further reduction to -3 +/- 12% after stent placement (p less than 0.001). There were no acute stent thromboses, but one patient (with two stents and unstented distal disease) developed subacute thrombosis on day 8 after self-discontinuation of warfarin and was treated with thrombolytic therapy and redilation. Follow-up angiography was performed at 4 to 6 months in 25 patients, demonstrating restenosis (83 +/- 13%) in 4 (57%) of 7 patients with multiple stents, but only 3 (17%) of 18 patients with a single stent (p less than 0.05). Six of the seven in-stent restenotic lesions were subtotal (80 +/- 12%) and were subjected to repeat conventional balloon angioplasty (postdilation stenosis 13 +/- 21%). The 18 patients without restenosis had a maximal in-stent diameter stenosis of 29 +/- 15%, corresponding to a maximal focal neointimal thickness of 0.68 +/- 0.26 mm within the stented segment. These preliminary results suggest that the Schatz-Palmaz stent may be a useful adjunctive device in the performance of coronary angioplasty.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2373812     DOI: 10.1016/0735-1097(90)90582-a

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  4 in total

1.  Intracoronary stents.

Authors:  M T Rothman; S W Davies
Journal:  Br Heart J       Date:  1992-06

2.  Use of an intravascular endoprosthesis (stent) to establish and maintain short-term patency of the ductus arteriosus in newborn lambs.

Authors:  J W Moore; W C Kirby; E J Lovett; J T O'Neill
Journal:  Cardiovasc Intervent Radiol       Date:  1991 Sep-Oct       Impact factor: 2.740

3.  Use of balloon-expandable stents to treat experimental peripheral pulmonary artery and superior vena caval stenosis: preliminary experience.

Authors:  A P Rocchini; J N Meliones; R H Beekman; C Moorehead; M London
Journal:  Pediatr Cardiol       Date:  1992-04       Impact factor: 1.655

4.  Transcatheter stent implantation to treat aortic coarctation in infancy.

Authors:  A N Redington; A M Hayes; S Y Ho
Journal:  Br Heart J       Date:  1993-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.