Literature DB >> 1933975

Use of an intravascular endoprosthesis (stent) to establish and maintain short-term patency of the ductus arteriosus in newborn lambs.

J W Moore1, W C Kirby, E J Lovett, J T O'Neill.   

Abstract

The feasibility of stenting the ductus arteriosus with a balloon-expandable vascular endoprosthesis was tested in 8 newborn lambs. Tantalum wire and stainless steel mesh coronary stents were implanted antegrade or retrograde by percutaneous transfemoral catheterization. One lamb died during the procedure from perforation of the aorta. In 7 lambs, the ductus arteriosus was crossed using endhole catheters and wires, and stents mounted on angioplasty catheters were expanded in the ductus arteriosus. Six lambs had successful implantation and had maintained a sizeable patent ductus arteriosus at 2 h. We conclude that the feasibility of percutaneous stenting of the newborn ductus was demonstrated. By providing patency of the ductus arteriosus, stents may offer nonsurgical alternatives for palliation of cyanotic congenital heart disease and hypoplastic left heart syndrome.

Entities:  

Mesh:

Year:  1991        PMID: 1933975     DOI: 10.1007/bf02578454

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  7 in total

Review 1.  A view of vascular stents.

Authors:  R A Schatz
Journal:  Circulation       Date:  1989-02       Impact factor: 29.690

2.  Placement of balloon-expandable intraluminal stents in iliac arteries: first 171 procedures.

Authors:  J C Palmaz; O J Garcia; R A Schatz; C R Rees; T Roeren; G M Richter; G Noeldge; G A Gardiner; G J Becker; C Walker
Journal:  Radiology       Date:  1990-03       Impact factor: 11.105

3.  Implantation of balloon-expandable intravascular grafts by catheterization in pulmonary arteries and systemic veins.

Authors:  C E Mullins; M P O'Laughlin; G W Vick; D C Mayer; T J Myers; D L Kearney; R A Schatz; J C Palmaz
Journal:  Circulation       Date:  1988-01       Impact factor: 29.690

4.  Expandable intraluminal graft: a preliminary study. Work in progress.

Authors:  J C Palmaz; R R Sibbitt; S R Reuter; F O Tio; W J Rice
Journal:  Radiology       Date:  1985-07       Impact factor: 11.105

5.  Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty.

Authors:  U Sigwart; J Puel; V Mirkovitch; F Joffre; L Kappenberger
Journal:  N Engl J Med       Date:  1987-03-19       Impact factor: 91.245

6.  Balloon-expandable intracoronary stents in the adult dog.

Authors:  R A Schatz; J C Palmaz; F O Tio; F Garcia; O Garcia; S R Reuter
Journal:  Circulation       Date:  1987-08       Impact factor: 29.690

7.  Clinical and angiographic results of balloon-expandable intracoronary stents in right coronary artery stenoses.

Authors:  M J Levine; B M Leonard; J A Burke; I D Nash; R D Safian; D J Diver; D S Baim
Journal:  J Am Coll Cardiol       Date:  1990-08       Impact factor: 24.094

  7 in total
  5 in total

1.  Stenting the arterial duct.

Authors:  J L Gibbs
Journal:  Arch Dis Child       Date:  1995-03       Impact factor: 3.791

2.  Transcatheter intervention for the treatment of congenital cardiac defects.

Authors:  R G Grifka
Journal:  Tex Heart Inst J       Date:  1997

3.  Ductus Arteriosus Stenting in Newborns - Transcatheter Approach as a Bridge Therapy for Corrective Surgery.

Authors:  Hiyam Mahmoud; Tammam Youssef; Eliza Cinteza; Cristiana Voicu; Adrian Balan; Irina Margarint; Cristina Filip; Georgiana Nicolae; Gabriela Duica; Alin Nicolescu; Ileana Barascu; Catalin Cirstoveanu
Journal:  Maedica (Bucur)       Date:  2022-03

4.  Axillary artery access for cardiac interventions in newborns.

Authors:  Dietmar Schranz; Ina Michel-Behnke
Journal:  Ann Pediatr Cardiol       Date:  2008-07

Review 5.  A review of ductal stenting in hypoplastic left heart syndrome: bridge to transplantation and hybrid stage I palliation.

Authors:  D J DiBardino; D B McElhinney; A C Marshall; E A Bacha
Journal:  Pediatr Cardiol       Date:  2007-10-03       Impact factor: 1.655

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.