BACKGROUND: Iodinated and gadolinium contrast agents pose some risk for certain pediatric patients, including allergic-like reactions, contrast-induced nephropathy (CIN) and nephrogenic systemic fibrosis (NSF). Digital flat-panel detectors enhance image quality during angiography and might allow use of more dilute contrast material to decrease risk of complications that might be dose-dependent, such as CIN and NSF.
OBJECTIVE: To assess the maximum dilution factors for iodine- and gadolinium-based contrast agents suitable for vascular imaging with fluoroscopy and digital subtraction angiography (DSA) on digital flat-panel detectors in an animal model.
MATERIALS AND METHODS: We performed selective catheterization of the abdominal aorta, renal artery and common carotid artery on a rabbit. In each vessel we performed fluoroscopy and DSA during contrast material injection using iodinated and gadolinium contrast material at 100%, 80%, 50%, 33% and 20% dilutions. An image quality score (0 to 3) was assigned by each of eight evaluators. Intracorrelation coefficient, paired t-test, one-way repeated analysis of variance, Spearman correlation and receiver operating characteristic curve analysis were applied to the data.
RESULTS: Overall the image quality scores correlated linearly with dilution levels. For iodinated contrast material, the optimum cut-off level for DSA when a score of at least 2 is acceptable is above 33%; it is above 50% when a score of 3 is necessary. For gadolinium contrast material, the optimum cut-off for DSA images is above 50% when a score of at least 2 is acceptable and above 80% when a score of 3 is necessary.
CONCLUSION: Knowledge of the relationship between image quality and contrast material dilution might allow a decrease in overall contrast load while maintaining appropriate image quality when using digital flat-panel detectors.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23736781     DOI: 10.1007/s00247-013-2723-0

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  24 in total

1.  Intravenous contrast medium-induced nephrotoxicity: is the medical risk really as great as we have come to believe?

Authors:  Richard W Katzberg; Jeffrey H Newhouse
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

Review 2.  Contrast-induced acute kidney injury.

Authors:  Richard Solomon; Harold L Dauerman
Journal:  Circulation       Date:  2010-12-07       Impact factor: 29.690

3.  Universal use of nonionic iodinated contrast medium for CT: evaluation of safety in a large urban teaching hospital.

Authors:  Koenraad J Mortelé; Maria-Raquel Oliva; Silvia Ondategui; Pablo R Ros; Stuart G Silverman
Journal:  AJR Am J Roentgenol       Date:  2005-01       Impact factor: 3.959

Review 4.  Current status of contrast-induced nephropathy and nephrogenic systemic fibrosis in children.

Authors:  Musturay Karcaaltincaba; Berna Oguz; Mithat Haliloglu
Journal:  Pediatr Radiol       Date:  2009-06

5.  Which study when? Iodinated contrast-enhanced CT versus gadolinium-enhanced MR imaging.

Authors:  Robert A Halvorsen
Journal:  Radiology       Date:  2008-10       Impact factor: 11.105

6.  Trends in adverse events after IV administration of contrast media.

Authors:  S T Cochran; K Bomyea; J W Sayre
Journal:  AJR Am J Roentgenol       Date:  2001-06       Impact factor: 3.959

7.  Gadopentetate dimeglumine as a contrast agent in common carotid arteriography.

Authors:  W K Erly; J Zaetta; G T Borders; H Ozgur; D R Gabaeff; R F Carmody; J Seeger
Journal:  AJNR Am J Neuroradiol       Date:  2000-05       Impact factor: 3.825

8.  Risk of nephropathy after consumption of nonionic contrast media by children undergoing cardiac angiography: a prospective study.

Authors:  Ghloamhossein Ajami; Ali Derakhshan; Hamid Amoozgar; Mohammad Mohamadi; Mohammad Borzouee; Mitra Basiratnia; Saeid Abtahi; Sirous Cheriki; Manochehr Soltani
Journal:  Pediatr Cardiol       Date:  2010-02-27       Impact factor: 1.655

9.  Frequency and severity of acute allergic-like reactions to gadolinium-containing i.v. contrast media in children and adults.

Authors:  Jonathan R Dillman; James H Ellis; Richard H Cohan; Peter J Strouse; Sophia C Jan
Journal:  AJR Am J Roentgenol       Date:  2007-12       Impact factor: 3.959

10.  Frequency of serum creatinine changes in the absence of iodinated contrast material: implications for studies of contrast nephrotoxicity.

Authors:  Jeffrey H Newhouse; David Kho; Qasim A Rao; Justin Starren
Journal:  AJR Am J Roentgenol       Date:  2008-08       Impact factor: 3.959

View more
  1 in total

1.  The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography.

Authors:  Toon Van Cauteren; Gert Van Gompel; Kaoru Tanaka; Douwe E Verdries; Dries Belsack; Koenraad H Nieboer; Inneke Willekens; Paul Evans; Sven Macholl; Guy Verfaillie; Steven Droogmans; Johan de Mey; Nico Buls
Journal:  Biomed Res Int       Date:  2017-05-23       Impact factor: 3.411

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.