Literature DB >> 18029897

Frequency and severity of acute allergic-like reactions to gadolinium-containing i.v. contrast media in children and adults.

Jonathan R Dillman1, James H Ellis, Richard H Cohan, Peter J Strouse, Sophia C Jan.   

Abstract

OBJECTIVE: The purpose of our study was to determine the frequency and severity of acute allergic-like reactions to i.v.-administered gadolinium-containing contrast media in children and adults.
MATERIALS AND METHODS: Pediatric (younger than 19 years) and adult department of radiology contrast material reaction forms involving patients who experienced acute allergic-like reactions to gadolinium-containing contrast media from January 1, 2001, through December 31, 2006, were retrospectively evaluated for the specific types of acute allergic-like reactions, reaction management, and patient outcomes. Relevant patient medical information, including documentation of prior gadolinium- or iodine-containing contrast material reaction, premedication before acute allergic-like reaction to i.v. gadolinium-containing contrast material, previous allergic reactions to substances other than contrast media, and history of asthma, was obtained by reviewing electronic medical records.
RESULTS: Seventy-eight thousand three hundred fifty-three (65,009 adult and 13,344 pediatric) i.v. administrations of gadolinium-containing contrast material were performed during the study period. Acute allergic-like reactions were documented after 54 injections (reaction frequency, 0.07%). Forty-eight reactions involved adult patients (adult reaction frequency, 0.07%), and six reactions occurred in pediatric patients (pediatric reaction frequency, 0.04%). Forty (74%) acute allergic-like reactions were mild, 10 (19%) were moderate, and four (7%) were severe. No gadolinium-containing contrast material-related death occurred during the study period. Twenty-six (50%) of 52 patients had one or more presumed risk factors for contrast material reaction.
CONCLUSION: Adult and pediatric acute allergic-like reactions to i.v.-administered gadolinium-containing contrast media are rare. Most of these reactions are mild; however, moderate and severe reactions that require immediate management do occur.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18029897     DOI: 10.2214/AJR.07.2554

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  79 in total

1.  Trace element analysis of human urine collected after administration of Gd-based MRI contrast agents: characterizing spectral interferences using inorganic mass spectrometry.

Authors:  Amy J Steuerwald; Patrick J Parsons; John G Arnason; Zhen Chen; C Matthew Peterson; Germaine M Buck Louis
Journal:  J Anal At Spectrom       Date:  2013-06       Impact factor: 4.023

2.  Cerebral lesions of multiple sclerosis: is gadolinium always irreplaceable in assessing lesion activity?

Authors:  Constantina Andrada Treabă; Rodica Bălaşa; Daniela Maria Podeanu; Iunius Paul Simu; Mircea Marian Buruian
Journal:  Diagn Interv Radiol       Date:  2014 Mar-Apr       Impact factor: 2.630

Review 3.  Gadolinium contrast agents for CNS imaging: current concepts and clinical evidence.

Authors:  E Kanal; K Maravilla; H A Rowley
Journal:  AJNR Am J Neuroradiol       Date:  2014-05-22       Impact factor: 3.825

Review 4.  Safety issues related to intravenous contrast agent use in magnetic resonance imaging.

Authors:  Skorn Ponrartana; Michael M Moore; Sherwin S Chan; Teresa Victoria; Jonathan R Dillman; Govind B Chavhan
Journal:  Pediatr Radiol       Date:  2021-04-19

Review 5.  Lymphotropic nanoparticle enhanced MRI for the staging of genitourinary tumors.

Authors:  Samdeep K Mouli; Lee C Zhao; Reed A Omary; C Shad Thaxton
Journal:  Nat Rev Urol       Date:  2010-01-19       Impact factor: 14.432

Review 6.  Is MRI imaging in pediatric age totally safe? A critical reprisal.

Authors:  Sergio Salerno; Claudio Granata; Marco Trapenese; Vittorio Cannata; Davide Curione; Maria Camilla Rossi Espagnet; Andrea Magistrelli; Paolo Tomà
Journal:  Radiol Med       Date:  2018-05-03       Impact factor: 3.469

Review 7.  Gadolinium-based contrast agents in children.

Authors:  Michael N Rozenfeld; Daniel J Podberesky
Journal:  Pediatr Radiol       Date:  2018-08-04

Review 8.  Perfusion MRI: the five most frequently asked technical questions.

Authors:  Marco Essig; Mark S Shiroishi; Thanh Binh Nguyen; Marc Saake; James M Provenzale; David Enterline; Nicoletta Anzalone; Arnd Dörfler; Alex Rovira; Max Wintermark; Meng Law
Journal:  AJR Am J Roentgenol       Date:  2013-01       Impact factor: 3.959

9.  Acute side effects of three commonly used gadolinium contrast agents in the paediatric population.

Authors:  Chris Neeley; Michael Moritz; Jeffrey J Brown; Yihua Zhou
Journal:  Br J Radiol       Date:  2016-05-19       Impact factor: 3.039

10.  Safety Report of Ferumoxytol for Magnetic Resonance Imaging in Children and Young Adults.

Authors:  Anne M Muehe; Dan Feng; Rie von Eyben; Sandra Luna-Fineman; Michael P Link; Travis Muthig; Amy E Huddleston; Edward A Neuwelt; Heike E Daldrup-Link
Journal:  Invest Radiol       Date:  2016-04       Impact factor: 6.016