Literature DB >> 23726473

High-spatial-resolution isotropic three-dimensional fast-recovery fast spin-echo magnetic resonance dacryocystography combined with topical administration of sterile saline solution.

Zhang Jing1, Chen Lang, Wang Qiu-Xia, Liu Rong, Luo Xin, Zhu Wen-Zhen, Xia Li-Ming, Qi Jian-Pin, Wang He.   

Abstract

OBJECTIVE: This study aims to investigate the clinical performance of three-dimensional (3D) fast-recovery fast spin-echo (FRFSE) magnetic resonance dacryocystography (MRD) with topical administration of sterile saline solution for the assessment of the lacrimal drainage system (LDS).
METHODS: A total of 13 healthy volunteers underwent both 3D-FRFSE MRD and two-dimensional (2D)-impulse recovery (IR)-single-shot fast spin-echo (SSFSE) MRD after topical administration of sterile saline solution, and 31 patients affected by primary LDS outflow impairment or postsurgical recurrent epiphora underwent 3D-FRFSE MRD and conventional T1- and T2-weighted sequences. All patients underwent lacrimal endoscopy or surgery, which served as a standard of reference for confirming the MRD findings.
RESULTS: 3D-FRFSE MRD detected more visualized superior and inferior canaliculi and nasolacrimal duct than 2D-IR-SSFSE MRD. Compared with 2D-IR-SSFSE MRD, 3D-FRFSE MRD showed more visualized segments per LDS, although the difference was not statistically significant. Significant improvements in the inferior canaliculus and nasolacrimal duct visibility grades were achieved using 3D-FRFSE MRD. 3D-FRFSE MRD had 100% sensitivity and 63.6% specificity for detecting LDS obstruction. In 51 out of the 62 LDSs that were assessed, a 90% agreement was noted between the findings of 3D-FRFSE MRD and lacrimal endoscopy in detecting the obstruction level.
CONCLUSION: 3D-FRFSE MRD combined with topical administration of sterile saline solution is a simple and noninvasive method of obtaining detailed morphological and functional information on the LDS. Overall, 3D-FRFSE MRD could be used as a reliable diagnostic method in many patients with epiphora prior to surgery.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Epiphora; Lacrimal apparatus; Magnetic resonance imaging; Topical administration

Mesh:

Substances:

Year:  2013        PMID: 23726473     DOI: 10.1016/j.ejrad.2013.04.013

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  2 in total

1.  Diagnostic performance of the three-dimensional fast spin echo-Cube sequence in comparison with a conventional imaging protocol in evaluation of the lachrymal drainage system.

Authors:  Jing Zhang; Lang Chen; Qiu-Xia Wang; Rong Liu; Wen-Zhen Zhu; Xin Luo; Li Peng; Wei Xiong
Journal:  Eur Radiol       Date:  2014-10-15       Impact factor: 5.315

2.  Isotropic three-dimensional fast spin-echo Cube magnetic resonance dacryocystography: comparison with the three-dimensional fast-recovery fast spin-echo technique.

Authors:  Jing Zhang; Lang Chen; Qiu-Xia Wang; Rong Liu; Wen-Zhen Zhu; Xin Luo; Li Peng; Wei Xiong
Journal:  Neuroradiology       Date:  2015-01-13       Impact factor: 2.804

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.