Using a registration-based motion correction algorithm to correct for respiratory motion during myocardial perfusion imaging.

Shelley Redgate1, David C Barber, Abdallah Al-Mohammad, Wendy B Tindale.   

Abstract

OBJECTIVE: The aim of the study was to develop and evaluate a registration-based motion correction algorithm as a method of reducing respiratory motion artefacts in myocardial perfusion imaging.
MATERIALS AND METHODS: The NCAT software was used to build nine male and nine female computer simulations of myocardial perfusion imaging data, with different respiratory motions and left ventricular ejection fractions. Imaging data were generated at various time points throughout each cardiac cycle. The data were summed over each cardiac cycle, forward projected, normalized, noise added and reconstructed with and without motion correction. Motion correction was performed using an algorithm that aligns images within a projection using nonlinear registrations. A standard simulation with no respiratory motion was also generated for comparison. The algorithm was applied to the standard to determine its effect on images with no respiratory motion.
RESULTS: The median difference in mean segmental counts compared with the standard was calculated for each simulation. The mean (range) of these values was 3% (1-6%), 14% (12-16%) and 28% (28-29%) for displacements of 1, 2 and 3 cm, respectively. The largest changes occurred inferiorly and anteriorly. Motion correction reduced these differences to 2% (0-4%), 5% (2-7%) and 7% (7-7%), respectively. The process of correcting for motion reduced the mean counts in all segments by 3% (1-5%).
CONCLUSION: Artefacts resulting from respiratory motion are improved using our algorithm when motion is 2 cm or greater.

Mesh:

Year:  2013        PMID: 23722349     DOI: 10.1097/MNM.0b013e328362ad3d

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  3 in total

1.  Influence of respiratory motion correction on quantification of myocardial perfusion SPECT.

Authors:  Ahmad Bitarafan-Rajabi; Hossein Rajabi; Feridoon Rastgou; Hasan Firoozabady; Nahid Yaghoobi; Hadi Malek; Werner Langesteger; Mohsen Beheshti
Journal:  J Nucl Cardiol       Date:  2014-12-17       Impact factor: 5.952

2.  The effect of patient anxiety and depression on motion during myocardial perfusion SPECT imaging.

Authors:  Vassiliki Lyra; Maria Kallergi; Emmanouil Rizos; Georgios Lamprakopoulos; Sofia N Chatziioannou
Journal:  BMC Med Imaging       Date:  2016-08-22       Impact factor: 1.930

Review 3.  An Overview on Image Registration Techniques for Cardiac Diagnosis and Treatment.

Authors:  Azira Khalil; Siew-Cheok Ng; Yih Miin Liew; Khin Wee Lai
Journal:  Cardiol Res Pract       Date:  2018-08-08       Impact factor: 1.866

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.