Literature DB >> 23721897

In vitro and in vivo imaging characteristics assessment of polymeric coils compared with standard platinum coils for the treatment of intracranial aneurysms.

P Mordasini1, A K Kraehenbuehl, J V Byrne, S Vandenberghe, M Reinert, H Hoppe, J Gralla.   

Abstract

BACKGROUND AND
PURPOSE: Conventional platinum coils cause imaging artifacts that reduce imaging quality and therefore impair imaging interpretation on intraprocedural or noninvasive follow-up imaging. The purpose of this study was to evaluate imaging characteristics and artifact production of polymeric coils compared with standard platinum coils in vitro and in vivo.
MATERIALS AND METHODS: Polymeric coils and standard platinum coils were evaluated in vitro with the use of 2 identical silicon aneurysm models coiled with a packing attenuation of 20% each. DSA, flat panel CT, CT, and MR imaging were performed. In vivo evaluation of imaging characteristics of polymeric coils was performed in experimentally created rabbit carotid bifurcation aneurysms. DSA, CT/CTA, and MR imaging were performed after endovascular treatment of the aneurysms. Images were evaluated regarding visibility of individual coils, coil mass, artifact production, and visibility of residual flow within the aneurysm.
RESULTS: Overall, in vitro and in vivo imaging showed relevantly reduced artifact production of polymeric coils in all imaging modalities compared with standard platinum coils. Image quality of CT and MR imaging was improved with the use of polymeric coils, which permitted enhanced depiction of individual coil loops and residual aneurysm lumen as well as the peri-aneurysmal area. Remarkably, CT images demonstrated considerably improved image quality with only minor artifacts compared with standard coils. On DSA, polymeric coils showed transparency and allowed visualization of superimposed vessel structures.
CONCLUSIONS: This initial experimental study showed improved imaging quality with the use of polymeric coils compared with standard platinum coils in all imaging modalities. This might be advantageous for improved intraprocedural imaging for the detection of complications and posttreatment noninvasive follow-up imaging.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23721897      PMCID: PMC7964839          DOI: 10.3174/ajnr.A3589

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  27 in total

1.  Production of experimental aneurysms at a surgically created arterial bifurcation.

Authors:  M D Forrest; G V O'Reilly
Journal:  AJNR Am J Neuroradiol       Date:  1989 Mar-Apr       Impact factor: 3.825

2.  Repeat endovascular treatment in post-embolization recurrent intracranial aneurysms.

Authors:  Hyun-Seung Kang; Moon Hee Han; Bae Ju Kwon; O-Ki Kwon; Sung Hyun Kim
Journal:  Neurosurgery       Date:  2006-01       Impact factor: 4.654

3.  MR angiography with ultrashort echo time in cerebral aneurysms treated with Guglielmi detachable coils.

Authors:  F Gönner; O Heid; L Remonda; G Nicoli; R W Baumgartner; N Godoy; G Schroth
Journal:  AJNR Am J Neuroradiol       Date:  1998-08       Impact factor: 3.825

4.  Preparation, characterization, and evaluation of radiopaque hydrogel filaments for endovascular embolization.

Authors:  Michael J Constant; Edward M Keeley; Gregory M Cruise
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2009-05       Impact factor: 3.368

5.  Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils.

Authors:  Jean Raymond; François Guilbert; Alain Weill; Stavros A Georganos; Louis Juravsky; Anick Lambert; Julie Lamoureux; Miguel Chagnon; Daniel Roy
Journal:  Stroke       Date:  2003-05-29       Impact factor: 7.914

6.  Endovascular occlusion of intracranial aneurysms with electrically detachable coils: correlation of aneurysm neck size and treatment results.

Authors:  A Fernandez Zubillaga; G Guglielmi; F Viñuela; G R Duckwiler
Journal:  AJNR Am J Neuroradiol       Date:  1994-05       Impact factor: 3.825

7.  Long-term follow-up of cerebral aneurysms after endovascular therapy prediction and outcome of retreatment.

Authors:  T Ries; S Siemonsen; G Thomalla; U Grzyska; H Zeumer; J Fiehler
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-20       Impact factor: 3.825

8.  Characterization of aneurysm remnants after endovascular treatment: contrast-enhanced MR angiography versus catheter digital subtraction angiography.

Authors:  R Agid; R A Willinsky; S-K Lee; K G Terbrugge; R I Farb
Journal:  AJNR Am J Neuroradiol       Date:  2008-05-22       Impact factor: 3.825

9.  Complications of diagnostic cerebral angiography: evaluation of 19,826 consecutive patients.

Authors:  Timothy J Kaufmann; John Huston; Jay N Mandrekar; Cathy D Schleck; Kent R Thielen; David F Kallmes
Journal:  Radiology       Date:  2007-06       Impact factor: 11.105

10.  Three-dimensional time-of-flight MR angiography at 3 T compared to digital subtraction angiography in the follow-up of ruptured and coiled intracranial aneurysms: a prospective study.

Authors:  H Urbach; U Dorenbeck; M von Falkenhausen; K Wilhelm; W Willinek; C Schaller; S Flacke
Journal:  Neuroradiology       Date:  2008-05       Impact factor: 2.804

View more
  1 in total

1.  High-flow venous pouch aneurysm in the rabbit carotid artery: A model for large aneurysms.

Authors:  Anna K Krähenbühl; Jan Gralla; Janine Abu-Isa; Pasquale Mordasini; Hans R Widmer; Andreas Raabe; Michael Reinert
Journal:  Interv Neuroradiol       Date:  2015-05-26       Impact factor: 1.610