Literature DB >> 23720420

Effect of echo-sampling strategy on the accuracy of out-of-phase and in-phase multiecho gradient-echo MRI hepatic fat fraction estimation.

Yakir S Levin1, Takeshi Yokoo, Tanya Wolfson, Anthony C Gamst, Julie Collins, Emil A Achmad, Gavin Hamilton, Michael S Middleton, Rohit Loomba, Claude B Sirlin.   

Abstract

PURPOSE: To assess the effect of echo-sampling strategy on the accuracy of out-of-phase (OP) and in-phase (IP) multiecho gradient-echo magnetic resonance imaging (MRI) hepatic fat fraction (FF) estimation, using MR spectroscopy (MRS) proton density FF (PDFF) as a reference standard.
MATERIALS AND METHODS: In this Institutional Review Board (IRB)-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant prospective study, 84 subjects underwent proton MRS and non-T1 -weighted gradient-echo imaging of the liver at 3T. Imaging data were collected at 16 nominally OP and IP echo times (TEs). MRI-FF was estimated while varying two echo-sampling parameters (number of consecutive echoes, starting echo number). For each combination of these parameters, MRI-FF estimation accuracy was assessed with slope, intercept, average bias, and R2 from a linear regression of MRS-PDFF on MRI-FF. The relationship between accuracy metrics and echo-sampling parameters was assessed by Spearman rank correlation.
RESULTS: For FF calculations using 3-16 echoes and a starting echo number of 1, the intercept ranged from 0.0046 to 0.0124, slope from 0.941 to 0.96, average bias from 0.0034 to 0.0078, and R2 from 0.968 to 0.976. All four accuracy metrics were the best with the 3- and 4-echo calculations and worsened progressively with an increasing number of echoes. For a given number of echoes, there was an overall trend toward decreasing accuracy as starting echo number increased. Spearman correlation coefficients between starting echo number and intercept, slope, average bias, and R2 were 0.911, -0.64, -0.889, and -0.954, respectively, indicating progressive loss of accuracy in each case.
CONCLUSION: Multiecho OP and IP imaging provided high FF estimation accuracy. Accuracy was highest using the earliest 3 or 4 echoes. Incorporation of additional echoes or delaying the starting echo number progressively reduced accuracy.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  fat quantification; fatty liver disease; hepatic steatosis; magnetic resonance; multiecho

Mesh:

Year:  2013        PMID: 23720420      PMCID: PMC3760998          DOI: 10.1002/jmri.24193

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  10 in total

1.  Java-based graphical user interface for MRUI, a software package for quantitation of in vivo/medical magnetic resonance spectroscopy signals.

Authors:  A Naressi; C Couturier; I Castang; R de Beer; D Graveron-Demilly
Journal:  Comput Biol Med       Date:  2001-07       Impact factor: 4.589

2.  In vivo characterization of the liver fat ¹H MR spectrum.

Authors:  Gavin Hamilton; Takeshi Yokoo; Mark Bydder; Irene Cruite; Michael E Schroeder; Claude B Sirlin; Michael S Middleton
Journal:  NMR Biomed       Date:  2010-12-12       Impact factor: 4.044

3.  Relaxation effects in the quantification of fat using gradient echo imaging.

Authors:  Mark Bydder; Takeshi Yokoo; Gavin Hamilton; Michael S Middleton; Alyssa D Chavez; Jeffrey B Schwimmer; Joel E Lavine; Claude B Sirlin
Journal:  Magn Reson Imaging       Date:  2008-02-21       Impact factor: 2.546

4.  Optimal phased-array combination for spectroscopy.

Authors:  Mark Bydder; Gavin Hamilton; Takeshi Yokoo; Claude B Sirlin
Journal:  Magn Reson Imaging       Date:  2008-05-16       Impact factor: 2.546

5.  Quantification of liver fat using magnetic resonance spectroscopy.

Authors:  C Thomsen; U Becker; K Winkler; P Christoffersen; M Jensen; O Henriksen
Journal:  Magn Reson Imaging       Date:  1994       Impact factor: 2.546

6.  Measurement of intracellular triglyceride stores by H spectroscopy: validation in vivo.

Authors:  L S Szczepaniak; E E Babcock; F Schick; R L Dobbins; A Garg; D K Burns; J D McGarry; D T Stein
Journal:  Am J Physiol       Date:  1999-05

7.  Estimation of hepatic proton-density fat fraction by using MR imaging at 3.0 T.

Authors:  Takeshi Yokoo; Masoud Shiehmorteza; Gavin Hamilton; Tanya Wolfson; Michael E Schroeder; Michael S Middleton; Mark Bydder; Anthony C Gamst; Yuko Kono; Alexander Kuo; Heather M Patton; Santiago Horgan; Joel E Lavine; Jeffrey B Schwimmer; Claude B Sirlin
Journal:  Radiology       Date:  2011-01-06       Impact factor: 11.105

8.  Multiecho water-fat separation and simultaneous R2* estimation with multifrequency fat spectrum modeling.

Authors:  Huanzhou Yu; Ann Shimakawa; Charles A McKenzie; Ethan Brodsky; Jean H Brittain; Scott B Reeder
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

9.  Nonalcoholic fatty liver disease: diagnostic and fat-grading accuracy of low-flip-angle multiecho gradient-recalled-echo MR imaging at 1.5 T.

Authors:  Takeshi Yokoo; Mark Bydder; Gavin Hamilton; Michael S Middleton; Anthony C Gamst; Tanya Wolfson; Tarek Hassanein; Heather M Patton; Joel E Lavine; Jeffrey B Schwimmer; Claude B Sirlin
Journal:  Radiology       Date:  2009-02-12       Impact factor: 11.105

10.  Effect of PRESS and STEAM sequences on magnetic resonance spectroscopic liver fat quantification.

Authors:  Gavin Hamilton; Michael S Middleton; Mark Bydder; Takeshi Yokoo; Jeffrey B Schwimmer; Yuko Kono; Heather M Patton; Joel E Lavine; Claude B Sirlin
Journal:  J Magn Reson Imaging       Date:  2009-07       Impact factor: 4.813

  10 in total
  10 in total

1.  Accuracy of multiecho magnitude-based MRI (M-MRI) for estimation of hepatic proton density fat fraction (PDFF) in children.

Authors:  Kevin A Zand; Amol Shah; Elhamy Heba; Tanya Wolfson; Gavin Hamilton; Jessica Lam; Joshua Chen; Jonathan C Hooker; Anthony C Gamst; Michael S Middleton; Jeffrey B Schwimmer; Claude B Sirlin
Journal:  J Magn Reson Imaging       Date:  2015-04-03       Impact factor: 4.813

Review 2.  Fat Quantification in the Abdomen.

Authors:  Cheng William Hong; Soudabeh Fazeli Dehkordy; Jonathan C Hooker; Gavin Hamilton; Claude B Sirlin
Journal:  Top Magn Reson Imaging       Date:  2017-12

Review 3.  Linearity, Bias, and Precision of Hepatic Proton Density Fat Fraction Measurements by Using MR Imaging: A Meta-Analysis.

Authors:  Takeshi Yokoo; Suraj D Serai; Ali Pirasteh; Mustafa R Bashir; Gavin Hamilton; Diego Hernando; Houchun H Hu; Holger Hetterich; Jens-Peter Kühn; Guido M Kukuk; Rohit Loomba; Michael S Middleton; Nancy A Obuchowski; Ji Soo Song; An Tang; Xinhuai Wu; Scott B Reeder; Claude B Sirlin
Journal:  Radiology       Date:  2017-09-11       Impact factor: 11.105

4.  Multisite, multivendor validation of the accuracy and reproducibility of proton-density fat-fraction quantification at 1.5T and 3T using a fat-water phantom.

Authors:  Diego Hernando; Samir D Sharma; Mounes Aliyari Ghasabeh; Bret D Alvis; Sandeep S Arora; Gavin Hamilton; Li Pan; Jean M Shaffer; Keitaro Sofue; Nikolaus M Szeverenyi; E Brian Welch; Qing Yuan; Mustafa R Bashir; Ihab R Kamel; Mark J Rice; Claude B Sirlin; Takeshi Yokoo; Scott B Reeder
Journal:  Magn Reson Med       Date:  2016-04-15       Impact factor: 4.668

5.  Sources of systematic error in proton density fat fraction (PDFF) quantification in the liver evaluated from magnitude images with different numbers of echoes.

Authors:  Mark Bydder; Gavin Hamilton; Ludovic de Rochefort; Ajinkya Desai; Elhamy R Heba; Rohit Loomba; Jeffrey B Schwimmer; Nikolaus M Szeverenyi; Claude B Sirlin
Journal:  NMR Biomed       Date:  2017-11-12       Impact factor: 4.044

Review 6.  Noninvasive, Quantitative Assessment of Liver Fat by MRI-PDFF as an Endpoint in NASH Trials.

Authors:  Cyrielle Caussy; Scott B Reeder; Claude B Sirlin; Rohit Loomba
Journal:  Hepatology       Date:  2018-08       Impact factor: 17.425

7.  Accuracy and the effect of possible subject-based confounders of magnitude-based MRI for estimating hepatic proton density fat fraction in adults, using MR spectroscopy as reference.

Authors:  Elhamy R Heba; Ajinkya Desai; Kevin A Zand; Gavin Hamilton; Tanya Wolfson; Alexandra N Schlein; Anthony Gamst; Rohit Loomba; Claude B Sirlin; Michael S Middleton
Journal:  J Magn Reson Imaging       Date:  2015-07-22       Impact factor: 4.813

8.  Agreement between region-of-interest- and parametric map-based hepatic proton density fat fraction estimation in adults with chronic liver disease.

Authors:  Paul M Manning; Gavin Hamilton; Kang Wang; Chulhyun Park; Jonathan C Hooker; Tanya Wolfson; Anthony Gamst; William M Haufe; Alex N Schlein; Michael S Middleton; Claude B Sirlin
Journal:  Abdom Radiol (NY)       Date:  2017-03

9.  Platelet GPIbα is a mediator and potential interventional target for NASH and subsequent liver cancer.

Authors:  Mohsen Malehmir; Dominik Pfister; Suchira Gallage; Marta Szydlowska; Donato Inverso; Elena Kotsiliti; Valentina Leone; Moritz Peiseler; Bas G J Surewaard; Dominik Rath; Adnan Ali; Monika Julia Wolf; Hannah Drescher; Marc E Healy; Daniel Dauch; Daniela Kroy; Oliver Krenkel; Marlene Kohlhepp; Thomas Engleitner; Alexander Olkus; Tjeerd Sijmonsma; Julia Volz; Carsten Deppermann; David Stegner; Patrick Helbling; César Nombela-Arrieta; Anahita Rafiei; Martina Hinterleitner; Marcel Rall; Florian Baku; Oliver Borst; Caroline L Wilson; Jack Leslie; Tracy O'Connor; Christopher J Weston; Abhishek Chauhan; David H Adams; Lozan Sheriff; Ana Teijeiro; Marco Prinz; Ruzhica Bogeska; Natasha Anstee; Malte N Bongers; Mike Notohamiprodjo; Tobias Geisler; Dominic J Withers; Jerry Ware; Derek A Mann; Hellmut G Augustin; Alexandros Vegiopoulos; Michael D Milsom; Adam J Rose; Patricia F Lalor; Josep M Llovet; Roser Pinyol; Frank Tacke; Roland Rad; Matthias Matter; Nabil Djouder; Paul Kubes; Percy A Knolle; Kristian Unger; Lars Zender; Bernhard Nieswandt; Meinrad Gawaz; Achim Weber; Mathias Heikenwalder
Journal:  Nat Med       Date:  2019-04-01       Impact factor: 53.440

10.  Skeletal muscle fat quantification by dual-energy computed tomography in comparison with 3T MR imaging.

Authors:  I Molwitz; M Leiderer; R McDonough; R Fischer; A-K Ozga; C Ozden; E Tahir; D Koehler; G Adam; J Yamamura
Journal:  Eur Radiol       Date:  2021-03-26       Impact factor: 5.315

  10 in total