Literature DB >> 23709039

Fluorometric beam profiling of UV MALDI lasers.

Rory T Steven1, Andrew D Palmer, Josephine Bunch.   

Abstract

The photon distribution (beam profile) of the laser as projected onto the sample is an important variable in matrix assisted laser desorption ionization mass spectrometry (MALDI-MS). Measurement of the beam profile is, therefore, an important factor within MALDI-MS. In this study a simple, low-cost fluorometric laser beam profiling technique is presented and applied in conjunction with MALDI-MS experiments. A comparison of the beam profile information afforded by a commercial system and the fluorometric method is carried out to determine the variation of beam profile for an Nd:YVO4 laser operated between 1 and 25 kHz. The beam profile information can be used, in conjunction with corresponding ion yields, to inform MALDI-MS experiments. The fluorometric beam profiling technique is used to obtain information about the beam dimensions as incident upon the MALDI-MS sample plate in-source. These values are compared with equivalent information obtained from ablation of thin film α-cyano-4-hydroxycinnamic acid (CHCA). In this study, area estimation by ablation provided a value 1.6 times smaller than that obtained by the fluorometric method, demonstrating the need for caution when measuring beam profile and, therefore, fluence, in MALDI-MS. ᅟ

Entities:  

Year:  2013        PMID: 23709039     DOI: 10.1007/s13361-013-0650-9

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  20 in total

1.  The desorption process in MALDI.

Authors:  Klaus Dreisewerd
Journal:  Chem Rev       Date:  2003-02       Impact factor: 60.622

2.  Introduction of a 20 kHz Nd:YVO4 laser into a hybrid quadrupole time-of-flight mass spectrometer for MALDI-MS imaging.

Authors:  Paul J Trim; Marie-Claude Djidja; Sally J Atkinson; Keith Oakes; Laura M Cole; David M G Anderson; Philippa J Hart; Simona Francese; Malcolm R Clench
Journal:  Anal Bioanal Chem       Date:  2010-07-16       Impact factor: 4.142

3.  Exciton mobility and trapping in a MALDI matrix.

Authors:  Patrick D Setz; Richard Knochenmuss
Journal:  J Phys Chem A       Date:  2005-05-12       Impact factor: 2.781

4.  Optimizing UV laser focus profiles for improved MALDI performance.

Authors:  Armin Holle; Andreas Haase; Markus Kayser; Jens Höhndorf
Journal:  J Mass Spectrom       Date:  2006-06       Impact factor: 1.982

5.  MALDI-MS imaging of features smaller than the size of the laser beam.

Authors:  John C Jurchen; Stanislav S Rubakhin; Jonathan V Sweedler
Journal:  J Am Soc Mass Spectrom       Date:  2005-10       Impact factor: 3.109

6.  Two-step matrix application for the enhancement and imaging of latent fingermarks.

Authors:  L Ferguson; R Bradshaw; R Wolstenholme; M Clench; S Francese
Journal:  Anal Chem       Date:  2011-06-13       Impact factor: 6.986

7.  An ultraviolet/infrared matrix-assisted laser desorption ionization sample stage integrating scanning knife-edge and slit devices for laser beam analysis.

Authors:  Jens Soltwisch; Klaus Dreisewerd
Journal:  Rapid Commun Mass Spectrom       Date:  2011-05-15       Impact factor: 2.419

8.  A survey of useful salt additives in matrix-assisted laser desorption/ionization mass spectrometry and tandem mass spectrometry of lipids: introducing nitrates for improved analysis.

Authors:  Rian L Griffiths; Josephine Bunch
Journal:  Rapid Commun Mass Spectrom       Date:  2012-07-15       Impact factor: 2.419

9.  Dual source ion mobility-mass spectrometer for direct comparison of electrospray ionization and MALDI collision cross section measurements.

Authors:  Sevugarajan Sundarapandian; Jody C May; John A McLean
Journal:  Anal Chem       Date:  2010-04-15       Impact factor: 6.986

10.  Repeat MALDI MS imaging of a single tissue section using multiple matrices and tissue washes.

Authors:  Rory T Steven; Josephine Bunch
Journal:  Anal Bioanal Chem       Date:  2013-03-21       Impact factor: 4.142

View more
  2 in total

1.  Matrix Optical Absorption in UV-MALDI MS.

Authors:  Kenneth N Robinson; Rory T Steven; Josephine Bunch
Journal:  J Am Soc Mass Spectrom       Date:  2017-11-29       Impact factor: 3.109

2.  Probing the Relationship Between Detected Ion Intensity, Laser Fluence, and Beam Profile in Thin Film and Tissue in MALDI MSI.

Authors:  Rory T Steven; Alan M Race; Josephine Bunch
Journal:  J Am Soc Mass Spectrom       Date:  2016-05-20       Impact factor: 3.109

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.