Literature DB >> 23707948

Three-dimensional quantification of susceptibility artifacts from various metals in magnetic resonance images.

Haruki Imai1, Yoji Tanaka, Naoyuki Nomura, Yusuke Tsutsumi, Hisashi Doi, Zuisei Kanno, Kikuo Ohno, Takashi Ono, Takao Hanawa.   

Abstract

Susceptibility artifacts generated in magnetic resonance (MR) images were quantitatively evaluated for various metals using a three-dimensional (3-D) artifact rendering to demonstrate the correlation between magnetic susceptibility and artifact volume. Ten metals (stainless steel, Co-Cr alloy, Nb, Ti, Zr, Mo, Al, Sn, Cu and Ag) were prepared, and their magnetic susceptibilities measured using a magnetic balance. Each metal was embedded in a Ni-doped agarose gel phantom and the MR images of the metal-containing phantoms were taken using 1.5 and 3.0 T MR scanners under both fast spin echo and gradient echo conditions. 3-D renderings of the artifacts were constructed from the images and the artifact volumes were calculated for each metal. The artifact volumes of metals decreased with decreasing magnetic susceptibility, with the exception of Ag. Although Sn possesses the lowest absolute magnetic susceptibility (1.8×10(-6)), the artifact volume from Cu (-7.8×10(-6)) was smaller than that of Sn. This is because the magnetic susceptibility of Cu was close to that of the agarose gel phantom (-7.3×10(-6)). Since the difference in magnetic susceptibility between the agarose and Sn is close to that between the agarose and Ag (-17.5×10(-6)), their artifact volumes were almost the same, although they formed artifacts that were reversed in all three dimensions.
Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Artifact volume; Magnetic resonance imaging (MRI); Magnetic susceptibility; Susceptibility artifact

Mesh:

Substances:

Year:  2013        PMID: 23707948     DOI: 10.1016/j.actbio.2013.05.017

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  6 in total

1.  PETRA, MSVAT-SPACE and SEMAC sequences for metal artefact reduction in dental MR imaging.

Authors:  Tim Hilgenfeld; Marcel Prager; Alexander Heil; Franz Sebastian Schwindling; Mathias Nittka; David Grodzki; Peter Rammelsberg; Martin Bendszus; Sabine Heiland
Journal:  Eur Radiol       Date:  2017-07-11       Impact factor: 5.315

2.  Mechanical properties of orthodontic wires covered with a polyether ether ketone tube.

Authors:  Nobukazu Shirakawa; Toshio Iwata; Shinjiro Miyake; Takero Otuka; So Koizumi; Toshitugu Kawata
Journal:  Angle Orthod       Date:  2018-03-21       Impact factor: 2.079

3.  Magnetic resonance imaging artefacts caused by orthodontic appliances and/or implant-supported prosthesis: a systematic review.

Authors:  Katrine Mølgaard Johannsen; João Marcus de Carvalho E Silva Fuglsig; Brian Hansen; Ann Wenzel; Rubens Spin-Neto
Journal:  Oral Radiol       Date:  2022-09-30       Impact factor: 1.882

4.  Magnetic resonance imaging artifacts produced by dental implants with different geometries.

Authors:  Lauren Bohner; Norbert Meier; Felix Gremse; Pedro Tortamano; Johannes Kleinheinz; Marcel Hanisch
Journal:  Dentomaxillofac Radiol       Date:  2020-07-02       Impact factor: 2.419

5.  Susceptibility artifacts induced by crowns of different materials with prepared teeth and titanium implants in magnetic resonance imaging.

Authors:  Xiaomeng Gao; Qianbing Wan; Qingping Gao
Journal:  Sci Rep       Date:  2022-01-10       Impact factor: 4.379

6.  Influence of orthodontic appliance-derived artifacts on 3-T MRI movies.

Authors:  Erika Ozawa; Ei-Ichi Honda; Kulthida Nunthayanon Parakonthun; Hiroko Ohmori; Kazuo Shimazaki; Tohru Kurabayashi; Takashi Ono
Journal:  Prog Orthod       Date:  2018-02-19       Impact factor: 2.750

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.