Intracoronary optical coherence tomography and histology of overlapping everolimus-eluting bioresorbable vascular scaffolds in a porcine coronary artery model: the potential implications for clinical practice.

Vasim Farooq1, Patrick W Serruys, Jung Ho Heo, Bill D Gogas, Yoshinobu Onuma, Laura E Perkins, Roberto Diletti, Maria D Radu, Lorenz Räber, Christos V Bourantas, Yaojun Zhang, Eric van Remortel, Ravindra Pawar, Richard J Rapoza, Jennifer C Powers, Heleen M M van Beusekom, Hector M Garcìa-Garcìa, Renu Virmani.   

Abstract

OBJECTIVES: This study sought to assess the vascular response of overlapping Absorb stents compared with overlapping newer-generation everolimus-eluting metallic platform stents (Xience V [XV]) in a porcine coronary artery model.
BACKGROUND: The everolimus-eluting bioresorbable vascular scaffold (Absorb) is a novel approach to treating coronary lesions. A persistent inflammatory response, fibrin deposition, and delayed endothelialization have been reported with overlapping first-generation drug-eluting stents.
METHODS: Forty-one overlapping Absorb and overlapping Xience V (XV) devices (3.0 × 12 mm) were implanted in the main coronary arteries of 17 nonatherosclerotic pigs with 10% overstretch. Implanted coronary arteries were evaluated by optical coherence tomography (OCT) at 28 days (Absorb n = 11, XV n = 7) and 90 days (Absorb n = 11, XV n = 8), with immediate histological evaluation following euthanasia at the same time points. One animal from each time point was evaluated with scanning electron microscopy alone. A total of 1,407 cross sections were analyzed by OCT and 148 cross sections analyzed histologically.
RESULTS: At 28 days in the overlap, OCT analyses indicated 80.1% of Absorb struts and 99.4% of XV struts to be covered (p < 0.0001), corresponding to histological observations of struts with cellular coverage of 75.4% and 99.6%, respectively (p < 0.001). Uncovered struts were almost exclusively related to the presence of "stacked" Absorb struts, that is, with a direct overlay configuration. At 90 days, overlapping Absorb and overlapping XV struts demonstrated >99% strut coverage by OCT and histology, with no evidence of a significant inflammatory process, and comparable % volume obstructions.
CONCLUSIONS: In porcine coronary arteries implanted with overlapping Absorb or overlapping XV struts, strut coverage is delayed at 28 days in overlapping Absorb, dependent on the overlay configuration of the thicker Absorb struts. At 90 days, both overlapping Absorb and overlapping XV have comparable strut coverage. The implications of increased strut thickness may have important clinical and design considerations for bioresorbable platforms.
Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23702016     DOI: 10.1016/j.jcin.2012.12.131

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  22 in total

1.  Histological validation of frequency domain optical coherence tomography for the evaluation of neointimal formation after a novel polymer-free sirolimus-eluting stent implantation.

Authors:  Qiang Fu; Hongyu Hu; Wei Chen; Zhixu Tan; Li Li; Dezhao Wang; Buxing Chen
Journal:  Int J Clin Exp Pathol       Date:  2015-09-01

2.  Bioresorbable vascular scaffold overlap evaluation with optical coherence tomography after implantation with or without enhanced stent visualization system (WOLFIE study): a two-centre prospective comparison.

Authors:  Simone Biscaglia; Gianluca Campo; Matteo Tebaldi; Carlo Tumscitz; Rita Pavasini; Luca Fileti; Gioel G Secco; Carlo Di Mario; Roberto Ferrari
Journal:  Int J Cardiovasc Imaging       Date:  2015-09-01       Impact factor: 2.357

3.  Optical coherence tomography evaluation of the absorb bioresorbable scaffold performance for overlap versus non-overlap segments in patients with coronary chronic total occlusion: insight from the GHOST-CTO registry.

Authors:  Gabriel T R Pereira; Alessio La Manna; Yasuhiro Ichibori; Armando Vergara-Martel; Bruno Ramos Nascimento; Abdul Jawwad Samdani; Davide Capodanno; Guido D'Agosta; Giacomo Gravina; Giuseppe Venuti; Corrado Tamburino; Guilherme F Attizzani
Journal:  Int J Cardiovasc Imaging       Date:  2019-06-07       Impact factor: 2.357

4.  Effect of strut distribution on neointimal coverage of everolimus-eluting bioresorbable scaffolds: an optical coherence tomography study.

Authors:  Takao Sato; John Jose; Abdelhakim Allai; Mohamed El-Mawardy; Ralph Tölg; Gert Richardt; Mohamed Abdel-Wahab
Journal:  J Thromb Thrombolysis       Date:  2017-08       Impact factor: 2.300

5.  Overlapping implantation of bioresorbable novolimus-eluting scaffolds: an observational optical coherence tomography study.

Authors:  Florian Blachutzik; Niklas Boeder; Jens Wiebe; Alessio Mattesini; Oliver Dörr; Astrid Most; Timm Bauer; Monique Tröbs; Jens Röther; Christian Schlundt; Stephan Achenbach; Christian Hamm; Holger Nef
Journal:  Heart Vessels       Date:  2016-12-21       Impact factor: 2.037

6.  Neointimal response to everolimus-eluting bioresorbable scaffolds implanted at bifurcating coronary segments: insights from optical coherence tomography.

Authors:  Takao Sato; John Jose; Mohamed El-Mawardy; Dmitriy S Sulimov; Ralph Tölg; Gert Richardt; Mohamed Abdel-Wahab
Journal:  Int J Cardiovasc Imaging       Date:  2016-10-18       Impact factor: 2.357

7.  Predictors of acute scaffold recoil after implantation of the everolimus-eluting bioresorbable scaffold: an optical coherence tomography assessment in native coronary arteries.

Authors:  Takao Sato; John Jose; Mohamed El-Mawardy; Dmitriy S Sulimov; Ralph Tölg; Gert Richardt; Mohamed Abdel-Wahab
Journal:  Int J Cardiovasc Imaging       Date:  2016-10-19       Impact factor: 2.357

8.  The impact of Fourier-Domain optical coherence tomography catheter induced motion artefacts on quantitative measurements of a PLLA-based bioresorbable scaffold.

Authors:  N S van Ditzhuijzen; A Karanasos; N Bruining; M van den Heuvel; O Sorop; J Ligthart; K Witberg; H M Garcia-Garcia; F Zijlstra; D J Duncker; H M M van Beusekom; E Regar
Journal:  Int J Cardiovasc Imaging       Date:  2014-05-16       Impact factor: 2.357

Review 9.  The effects of novel, bioresorbable scaffolds on coronary vascular pathophysiology.

Authors:  Michael J Lipinski; Ricardo O Escarcega; Thibault Lhermusier; Ron Waksman
Journal:  J Cardiovasc Transl Res       Date:  2014-05-07       Impact factor: 4.132

10.  Dual modality intravascular optical coherence tomography (OCT) and near-infrared fluorescence (NIRF) imaging: a fully automated algorithm for the distance-calibration of NIRF signal intensity for quantitative molecular imaging.

Authors:  Giovanni J Ughi; Johan Verjans; Ali M Fard; Hao Wang; Eric Osborn; Tetsuya Hara; Adam Mauskapf; Farouc A Jaffer; Guillermo J Tearney
Journal:  Int J Cardiovasc Imaging       Date:  2014-10-24       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.