| Literature DB >> 2369199 |
Y Nakamura1, M Masuda, Y Toshima, T Asou, M Oe, K Kinoshita, Y Kawachi, J Tanaka, K Tokunaga.
Abstract
Hemoconcentration for the establishment of no-donor blood transfusion in open heart surgery was assessed in regard to both the saving of protein and platelets and the exclusion of free hemoglobin. Two different types of hemoconcentrator were compared: the ultrafilter (group I, 6 patients) and the Cell Saver (group II, 6 patients). The total serum protein level, expressed as the percent recovery of the preoperative value, after hemoconcentration was significantly higher in group I (group I versus group II: total serum protein, 118% versus 87% [p less than 0.05]; fibrinogen, 77% versus 50% [p less than 0.01]; immunoglobulin, 83% versus 60% [p less than 0.01]). The platelets also seemed to be well preserved after hemoconcentration in group I. Although the exclusion of free hemoglobin from plasma was inferior in group I compared with group II, the postoperative plasma free hemoglobin level did not increase in group I. We conclude that use of the Cell Saver in nontransfusion cardiopulmonary bypass might cause a severe depletion of various proteins and that the ultrafilter is both safer and more useful if employed routinely.Entities:
Mesh:
Substances:
Year: 1990 PMID: 2369199 DOI: 10.1016/0003-4975(90)90879-b
Source DB: PubMed Journal: Ann Thorac Surg ISSN: 0003-4975 Impact factor: 4.330