Literature DB >> 23684241

Clinical value of routine use of thin-section 3D MRI using 3D FSE sequences with a variable flip angle technique for internal derangements of the knee joint at 3T.

Hideyasu Kudo1, Tsutomu Inaoka, Noriko Kitamura, Tomoya Nakatsuka, Shusuke Kasuya, Rumiko Kasai, Mitsuyuki Tozawa, Koichi Nakagawa, Hitoshi Terada.   

Abstract

PURPOSE: To determine the clinical value of routine use of thin-section 3D MRI using 3D FSE sequences with a variable flip angle technique for internal derangements of the knee joint at 3T. METHOD AND MATERIALS: Thirty-four knees in 34 patients suspected of having internal derangements of the knee joint were included. Following standard 2D MRI protocol including sagittal PDWI, T1WI and T2*WI, coronal fat-suppressed PDWI, and axial fat-suppressed PDWI with 3-4mm thicknesses, fat-suppressed and water-excitation PDWI using 3D FSE sequences with a variable flip angle technique with 0.6mm thickness were obtained in coronal plane and the three major planes with 1mm thickness (3D MRI) was reformatted. The standard 2D MRI protocol and reformatted 3D MRI protocol (three sagittal 2D sequence images plus 3D MRI) were independently analyzed by two radiologists concerning presence or absence of lesions in the menisci, cartilage, and ligament. Interobserver agreements in both the MRI protocols were assessed by weighted-kappa coefficients. Regarding diagnostic accuracy, areas under the receiver operating characteristic curves (Az values) of both the MRI protocols were compared.
RESULTS: Thirty-eight meniscal lesions, 39 cartilage lesions, and 20 ligamentous lesions were surgically detected. Excellent interobserver agreements (kappa=0.91-0.98) were seen in both the MRI protocols, with a slightly better tendency in the reformatted 3D MRI protocol. Average Az values in detection of the meniscal, cartilage, and ligamentous lesions were significantly higher in the reformatted 3D MRI protocol than in the standard 2D MRI protocol (p<0.01 or p<0.001).
CONCLUSION: Routine use of reformatted thin-section 3D MRI using 3D FSE sequences with a variable flip angle technique may improve diagnostic accuracy and confidence in detection of internal derangements of the knee joint.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  3 T; Fast spin echo; Knee; MRI; Three-dimensional

Mesh:

Year:  2013        PMID: 23684241     DOI: 10.1016/j.mri.2013.02.003

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  6 in total

1.  Can a single isotropic 3D fast spin echo sequence replace three-plane standard proton density fat-saturated knee MRI at 1.5 T?

Authors:  B Pass; P Robinson; R Hodgson; A J Grainger
Journal:  Br J Radiol       Date:  2015-06-12       Impact factor: 3.039

2.  Knee imaging: Rapid three-dimensional fast spin-echo using compressed sensing.

Authors:  Richard Kijowski; Humberto Rosas; Alexey Samsonov; Kevin King; Rob Peters; Fang Liu
Journal:  J Magn Reson Imaging       Date:  2016-10-11       Impact factor: 4.813

3.  Accelerating Knee MRI: 3D Modulated Flip-Angle Technique in Refocused Imaging with an Extended Echo Train and Compressed Sensing.

Authors:  He Sui; Jin Li; Lin Liu; Zhongwen Lv; Yunfei Zhang; Yongming Dai; Zhanhao Mo
Journal:  J Pain Res       Date:  2022-02-25       Impact factor: 3.133

4.  High resolution MRI imaging at 9.4 Tesla of the osteochondral unit in a translational model of articular cartilage repair.

Authors:  Lars Goebel; Andreas Müller; Arno Bücker; Henning Madry
Journal:  BMC Musculoskelet Disord       Date:  2015-04-16       Impact factor: 2.362

5.  Fat-suppressed gadolinium-enhanced isotropic high-resolution 3D-GRE-T1WI for predicting small node metastases in patients with rectal cancer.

Authors:  Yan Chen; Xinyue Yang; Ziqiang Wen; Baolan Lu; Xiaojuan Xiao; Bingqi Shen; Shenping Yu
Journal:  Cancer Imaging       Date:  2018-05-21       Impact factor: 3.909

6.  Improved diagnostic accuracy for ulnar-sided TFCC lesions with radial reformation of 3D sequences in wrist MR arthrography.

Authors:  Henner Huflage; Karsten Sebastian Luetkens; Andreas Steven Kunz; Nora Conrads; Rafael Gregor Jakubietz; Michael Georg Jakubietz; Lenhard Pennig; Lukas Goertz; Thorsten Alexander Bley; Rainer Schmitt; Jan-Peter Grunz
Journal:  Eur Radiol       Date:  2021-05-18       Impact factor: 5.315

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.