Literature DB >> 23682510

Evaluation and comparison of the internal fit and marginal accuracy of base metal (nickelchromium) and zirconia copings before and after ceramic veneering: a sem study.

K M Regish1, D Sharma, D R Prithviraj, A Nair, R Raghavan.   

Abstract

This study compares the internal fit and marginal adaptation of copy milled Zirconia copings with Nickel-Chromium (Ni-Cr) copings fabricated using a lost wax technique before and after ceramic veneering. A standardized metal master die simulating a prepared crown was fabricated and twenty impressions of the metal die were made and poured with die stone. Wax patterns were made on ten dies and cast while light cure resin patterns were made on the other ten dies for copy milling the Zirconia copings. Five specimens from each group were subjected to ceramic veneering. All the test specimens were luted on to the fresh dies, embedded in dental plaster, sectioned and image analysis done using scanning electron microscopy. Thereafter statistical analysis is done using student t-test. The linear measurements for internal fit and marginal discrepancy were increased for Zirconia compared with Ni-Cr copings. The difference in the values of all the specimens of all the groups were not statistically significant (P > 0.05) except the values comparing the internal fit of Zirconia and Ni-Cr copings before ceramic veneering (P < 0.001) which was statistically significant. The internal fit and marginal adaptability of Ni-Cr copings were found to be better than the Copy milled Zirconia copings but internal fit and marginal adaptability deteriorated after ceramic veneering.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23682510

Source DB:  PubMed          Journal:  Eur J Prosthodont Restor Dent        ISSN: 0965-7452


  4 in total

1.  Assessment of internal fit and micro leakage of conventionally fabricated ceramometallic restoration versus CAD wax and press veneering (in-vitro study).

Authors:  Fatema Khaled Mansour; Rabab Mohammed Ibrahim; Hoda Mansour; Ahmed Mohamed Hamdy
Journal:  BDJ Open       Date:  2021-05-10

2.  Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems.

Authors:  Jong-Kyoung Park; Wan-Sun Lee; Hae-Young Kim; Woong-Chul Kim; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2015-04-23       Impact factor: 1.904

Review 3.  Fit of tooth-supported zirconia single crowns-A systematic review of the literature.

Authors:  Walaa Magdy Ahmed; Batoul Shariati; Arwa Z Gazzaz; Mohammed E Sayed; Ricardo M Carvalho
Journal:  Clin Exp Dent Res       Date:  2020-09-03

4.  Marginal Adaptation of Implant Prostheses Fabricated by Different Materials in Excessive Crown Height Space before and after Veneering.

Authors:  Safoura Ghodsi; Marzieh Alikhasi; Majid Sahebi; Vahideh Nazari
Journal:  Front Dent       Date:  2021-07-25
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.