Literature DB >> 23682289

A case demonstrating a percutaneous closure using the amplatzer duct occluder for paravalvular leakage after tricuspid valve replacement.

Young Hee Heo1, Soo-Jin Kim, Sang Yun Lee, Jae Suk Baek.   

Abstract

There has been a dramatic increase in the number and type of procedures performed in the field of cardiac intervention in the past decade. Percutaneous intervention is becoming an increasingly recognized modality for the management of prosthetic paravalvular leakages (PVLs) in severely symptomatic non-surgical candidates. Herein, we report our experience of percutaneous closure using the Amplatzer duct occluder for a PVL in a patient who underwent tricuspid valve replacement.

Entities:  

Keywords:  Amplatzer occluder; Cardiac valve prosthesis; Tricuspid regurgitation

Year:  2013        PMID: 23682289      PMCID: PMC3654117          DOI: 10.4070/kcj.2013.43.4.273

Source DB:  PubMed          Journal:  Korean Circ J        ISSN: 1738-5520            Impact factor:   3.243


  17 in total

1.  Coil embolization of a periprosthetic mitral valve leak associated with severe hemolytic anemia.

Authors:  M Moscucci; G M Deeb; D Bach; K A Eagle; D M Williams
Journal:  Circulation       Date:  2001-10-16       Impact factor: 29.690

2.  Percutaneous closure of an aortic prosthetic paravalvar leak: an Australian first.

Authors:  Jonathon P Fanning; Stephen V Cox; Gregory M Scalia
Journal:  Heart Lung Circ       Date:  2011-11-08       Impact factor: 2.975

3.  Secundum atrial septal defect. Nonoperative closure during cardiac catheterization.

Authors:  T D King; S L Thompson; C Steiner; N L Mills
Journal:  JAMA       Date:  1976-06-07       Impact factor: 56.272

4.  Factors associated with periprosthetic leakage following primary mitral valve replacement: with special consideration of the suture technique.

Authors:  J P Dhasmana; E H Blackstone; J W Kirklin; N T Kouchoukos
Journal:  Ann Thorac Surg       Date:  1983-02       Impact factor: 4.330

5.  Natural history of early aortic paraprosthetic regurgitation: a five-year follow-up.

Authors:  L S Rallidis; I E Moyssakis; I Ikonomidis; P Nihoyannopoulos
Journal:  Am Heart J       Date:  1999-08       Impact factor: 4.749

6.  Novel use of the Amplatzer duct occluder to close perivalvar leak involving a prosthetic mitral valve.

Authors:  Henry W Kort; Angela M Sharkey; David T Balzer
Journal:  Catheter Cardiovasc Interv       Date:  2004-04       Impact factor: 2.692

7.  Transcatheter umbrella closure of valvular and paravalvular leaks.

Authors:  M Hourihan; S B Perry; V S Mandell; J F Keane; J J Rome; J A Bittl; J E Lock
Journal:  J Am Coll Cardiol       Date:  1992-11-15       Impact factor: 24.094

8.  Prevalence and severity of paravalvular regurgitation in the Artificial Valve Endocarditis Reduction Trial (AVERT) echocardiography study.

Authors:  Victor G Dávila-Román; Alan D Waggoner; Elizabeth D Kennard; Richard Holubkov; W R Eric Jamieson; Lars Englberger; Thierry P Carrel; Hartzell V Schaff
Journal:  J Am Coll Cardiol       Date:  2004-10-06       Impact factor: 24.094

9.  Results of reoperation for periprosthetic leakage.

Authors:  T A Orszulak; H V Schaff; G K Danielson; J R Pluth; F J Puga; J M Piehler
Journal:  Ann Thorac Surg       Date:  1983-06       Impact factor: 4.330

10.  Percutaneous closure of perivalvular mitral regurgitation with an Amplatzer occluder device in a patient with both prosthetic mitral and aortic valves.

Authors:  David M Lasorda; Jamil C Mohsin
Journal:  J Interv Cardiol       Date:  2008-02-28       Impact factor: 2.279

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.