Literature DB >> 23682010

Indexed effective orifice area is a significant predictor of higher mid- and long-term mortality rates following aortic valve replacement in patients with prosthesis-patient mismatch.

Jian Chen1, Yiyun Lin, Bo Kang, Zhinong Wang.   

Abstract

Prosthesis-patient mismatch (PPM) is defined as a too-small effective orifice area (EOA) of an inserted prosthetic relative to body size, resulting in an abnormally high postoperative gradient. It is unclear, however, whether residual stenosis after aortic valve replacement (AVR) has a negative impact on mid- and long-term survivals. We searched electronic databases, including PubMed, Embase, Medline and the Cochrane controlled trials register, through October 2012, to identify published full-text English studies on the association between PPM and mortality rates. A significant PPM was defined as an indexed EOA (iEOA)<0.85 cm2/m2, and severe PPM as an iEOA<0.65 cm2/m2. Two reviewers independently assessed the studies for inclusion and extracted data. Fourteen observational studies, involving 14 874 patients, met our final inclusion criteria. Meta-analysis demonstrated that PPM significantly increased mid-term (odds ratio [OR] 1.42, 95% confidence interval [CI] 1.19-1.69) and long-term (OR 1.52, 95% CI 1.26-1.84) all-cause mortalities. Subgroup analysis showed that PPM was associated with higher mid- and long-term mortality rates only in younger and predominantly female populations. Risk-adjusted sensitivity analysis showed that severe PPM was associated with reduced survival (adjusted hazard ratio [HR] 1.50, 95% CI 1.24-1.80), whereas moderate PPM was not (adjusted HR 0.96, 95% CI 0.86-1.07). Regardless of severity, however, PPM had a negative effect on survival in patients with impaired ejection fraction (adjusted HR 1.26, 95% CI 1.09-1.47). PPM (iEOA<0.85 cm2/m2) after AVR tended to be associated with increased long-term all-cause mortality in younger patients, females and patients with preoperative left ventricular dysfunction. Severe PPM (iEOA<0.65 cm2/m2) was a significant predictor of reduced long-term survival in all populations undergoing AVR.

Entities:  

Keywords:  Aortic valve replacement; Effective orifice area; Meta-analysis; Prosthesis-patient mismatch

Mesh:

Year:  2013        PMID: 23682010     DOI: 10.1093/ejcts/ezt245

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  8 in total

1.  Early and late outcomes of AVR with aortic annular enlargement in octogenarian.

Authors:  Yuki Okamoto; Kazuo Yamamoto; Tsutomu Sugimoto; Shinpei Yoshii
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-05-14

2.  Mini-aortic valve replacements are not associated with an increased incidence of patient-prosthesis mismatch: a propensity-scored analysis.

Authors:  J Trent Magruder; Joshua C Grimm; Arman Kilic; Todd Crawford; John V Conte; Duke E Cameron; Ashish S Shah
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-12-19

3.  Patient prosthesis mismatch and its impact on left ventricular regression following aortic valve replacement in aortic stenosis patients.

Authors:  Abid Iqbal; Varghese Thomas Panicker; Jayakumar Karunakaran
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2018-08-28

4.  Aortic root widening: "pro et contra".

Authors:  Balaji Srimurugan; Neethu Krishna; Rajesh Jose; Kirun Gopal; Praveen Kerala Varma
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2021-02-22

5.  Determinants of effective orifice area in aortic valve replacement: anatomic and clinical factors.

Authors:  Hee Jung Kim; Sung Jun Park; Hyun Jung Koo; Joon-Won Kang; Dong Hyun Yang; Sung-Ho Jung; Suk Jung Choo; Cheol Hyun Chung; Jae Won Lee; Joon Bum Kim
Journal:  J Thorac Dis       Date:  2020-05       Impact factor: 2.895

6.  Durability of a bovine pericardial aortic bioprosthesis based on Valve Academic Research Consortium-3 echocardiographic criteria.

Authors:  Stéphane Kermen; Juliette Strella; Arthur Aupart; Fabien Espitalier; Michel Aupart; Anne Bernard; Thierry Bourguignon
Journal:  JTCVS Open       Date:  2022-05-29

7.  Perceval or Trifecta to Prevent Patient-Prosthesis Mismatch.

Authors:  Daniel Hernandez-Vaquero; Carlota Vigil-Escalera; Yvan Persia; Carlos Morales; Isaac Pascual; Alberto Domínguez-Rodríguez; Emiliano Rodríguez-Caulo; Manuel Carnero; Rocío Díaz; Pablo Avanzas; Cesar Moris; Jacobo Silva
Journal:  J Clin Med       Date:  2020-09-14       Impact factor: 4.241

8.  Incidence, predictors, and outcome of prosthesis-patient mismatch after transcatheter aortic valve replacement: A meta-analysis.

Authors:  Shixin He; Zhenfei Fang
Journal:  Medicine (Baltimore)       Date:  2020-06-12       Impact factor: 1.817

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.