Literature DB >> 23681924

Validation of the new Complior sensor to record pressure signals non-invasively.

Benjamin Sztrymf1, Frédéric Jacobs, Denis Chemla, Christian Richard, Sandrine C Millasseau.   

Abstract

The Complior device (Alam Medical, France) has contributed to the rise of arterial stiffness as a measure of cardiovascular risk. In its latest version (Complior Analyse) the sensor records pressure instead of distension waveforms thus allowing the measurement of central pressure and pulse wave analysis. The aim of our study was to verify that the new sensor measures pressure waveforms accurately in both time and frequency domain. Invasive and non-invasive signals were recorded simultaneously at the radial artery and compared in the frequency and time domain in haemodynamically stable intensive care unit patients. Twelve patients entered the study (8 men, 4 women, mean age 69 ± 17 years). Heart rate was 90 ± 15 bpm, systolic blood pressure 133 ± 19 mmHg and diastolic blood pressure 68 ± 15 mmHg. There was no statistical difference in the amplitude of harmonics between the invasive signal and Complior signal. When superimposing waveforms in the time domain, there was a small difference in the form factor (4.2 ± 2.8 %) and in the absolute area between the 2 waveforms (3.3 ± 1.7 mmHg·s(-1)). These differences were of the same magnitude as the beat-to-beat variation of the form factor (3.3 %) and of the absolute area (3.1 mmHg·s(-1)), respectively. The second systolic peak was detectable in 4 subjects, with no statistical difference between invasive and non-invasive values. The new pressure sensor of the Complior Analyse device recorded pressure waveforms accurately and could be used to perform pressure wave analysis.

Entities:  

Mesh:

Year:  2013        PMID: 23681924     DOI: 10.1007/s10877-013-9477-y

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  31 in total

1.  Estimating central systolic blood pressure during oscillometric determination of blood pressure: proof of concept and validation by comparison with intra-aortic pressure recording and arterial tonometry.

Authors:  Sally Emma Brett; Antoine Guilcher; Brian Clapp; Phil Chowienczyk
Journal:  Blood Press Monit       Date:  2012-06       Impact factor: 1.444

2.  Expert consensus document on arterial stiffness: methodological issues and clinical applications.

Authors:  Stephane Laurent; John Cockcroft; Luc Van Bortel; Pierre Boutouyrie; Cristina Giannattasio; Daniel Hayoz; Bruno Pannier; Charalambos Vlachopoulos; Ian Wilkinson; Harry Struijker-Boudier
Journal:  Eur Heart J       Date:  2006-09-25       Impact factor: 29.983

3.  Assessment of arterial distensibility by automatic pulse wave velocity measurement. Validation and clinical application studies.

Authors:  R Asmar; A Benetos; J Topouchian; P Laurent; B Pannier; A M Brisac; R Target; B I Levy
Journal:  Hypertension       Date:  1995-09       Impact factor: 10.190

4.  Radial late-SBP as a surrogate for central SBP.

Authors:  Yi Zhang; Davide Agnoletti; Athanase D Protogerou; Ji-Guang Wang; Jirar Topouchian; Paolo Salvi; Michel E Safar; Jacques Blacher
Journal:  J Hypertens       Date:  2011-04       Impact factor: 4.844

5.  Evaluation of the Vicorder, a novel cuff-based device for the noninvasive estimation of central blood pressure.

Authors:  Giacomo Pucci; Joseph Cheriyan; Annette Hubsch; Stacey S Hickson; Parag R Gajendragadkar; Timothy Watson; Michael O'Sullivan; Jean Woodcock-Smith; Giuseppe Schillaci; Ian B Wilkinson; Carmel M McEniery
Journal:  J Hypertens       Date:  2013-01       Impact factor: 4.844

6.  Amlodipine-valsartan combination decreases central systolic blood pressure more effectively than the amlodipine-atenolol combination: the EXPLOR study.

Authors:  Pierre Boutouyrie; Assya Achouba; Patrick Trunet; Stéphane Laurent
Journal:  Hypertension       Date:  2010-04-19       Impact factor: 10.190

7.  Pulse wave velocity as endpoint in large-scale intervention trial. The Complior study. Scientific, Quality Control, Coordination and Investigation Committees of the Complior Study.

Authors:  R Asmar; J Topouchian; B Pannier; A Benetos; M Safar
Journal:  J Hypertens       Date:  2001-04       Impact factor: 4.844

8.  Association between aldosterone induced by antihypertensive medication and arterial stiffness reduction: the J-CORE study.

Authors:  Yoshio Matsui; Kazuo Eguchi; Michael F O'Rourke; Joji Ishikawa; Kazuyuki Shimada; Kazuomi Kario
Journal:  Atherosclerosis       Date:  2010-12-30       Impact factor: 5.162

9.  Central pulse pressure and mortality in end-stage renal disease.

Authors:  Michel E Safar; Jacques Blacher; Bruno Pannier; Alain P Guerin; Sylvain J Marchais; Pierre-Marie Guyonvarc'h; Gérard M London
Journal:  Hypertension       Date:  2002-03-01       Impact factor: 10.190

10.  Central but not brachial blood pressure predicts cardiovascular events in an unselected geriatric population: the ICARe Dicomano Study.

Authors:  Riccardo Pini; M Chiara Cavallini; Vittorio Palmieri; Niccolò Marchionni; Mauro Di Bari; Richard B Devereux; Giulio Masotti; Mary J Roman
Journal:  J Am Coll Cardiol       Date:  2008-06-24       Impact factor: 24.094

View more
  2 in total

1.  Estimation of central arterial pressure from the radial artery in patients undergoing invasive neuroradiological procedures.

Authors:  Sabino Scolletta; Antoine Herpain; Salvatore Mario Romano; Fabio Silvio Taccone; Katia Donadello; Boris Lubicz; Federico Franchi; Keitiane Michele Kaefer; Enrico Polati; Jean-Louis Vincent; Daniel De Backer
Journal:  BMC Anesthesiol       Date:  2019-09-04       Impact factor: 2.217

2.  New Method to Estimate Central Systolic Blood Pressure From Peripheral Pressure: A Proof of Concept and Validation Study.

Authors:  Denis Chemla; Sandrine Millasseau; Olfa Hamzaoui; Jean-Louis Teboul; Xavier Monnet; Frédéric Michard; Mathieu Jozwiak
Journal:  Front Cardiovasc Med       Date:  2021-12-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.