Heat generation caused by ablation of dental hard tissues with an ultrashort pulse laser (USPL) system.

Andreas Braun1, Raphael Franz Krillke, Matthias Frentzen, Christoph Bourauel, Helmut Stark, Florian Schelle.   

Abstract

Heat generation during the removal of dental hard tissues may lead to a temperature increase and cause painful sensations or damage dental tissues. The aim of this study was to assess heat generation in dental hard tissues following laser ablation using an ultrashort pulse laser (USPL) system. A total of 85 specimens of dental hard tissues were used, comprising 45 specimens of human dentine evaluating a thickness of 1, 2, and 3 mm (15 samples each) and 40 specimens of human enamel with a thickness of 1 and 2 mm (20 samples each). Ablation was performed with an Nd:YVO4 laser at 1,064 nm, a pulse duration of 9 ps, and a repetition rate of 500 kHz with an average output power of 6 W. Specimens were irradiated for 0.8 s. Employing a scanner system, rectangular cavities of 1-mm edge length were generated. A temperature sensor was placed at the back of the specimens, recording the temperature during the ablation process. All measurements were made employing a heat-conductive paste without any additional cooling or spray. Heat generation during laser ablation depended on the dental hard tissue (enamel or dentine) and the thickness of the respective tissue (p < 0.05). Highest temperature increase could be observed in the 1-mm thickness group for enamel. Evaluating the 1-mm group for dentine, a significantly lower temperature increase could be measured (p < 0.05) with lowest values in the 3-mm group (p < 0.05). A time delay for temperature increase during the ablation process depending on the material thickness was observed for both hard tissues (p < 0.05). Employing the USPL system to remove dental hard tissues, heat generation has to be considered. Especially during laser ablation next to pulpal tissues, painful sensations and potential thermal injury of pulp tissue might occur.

Entities:  

Mesh:

Year:  2013        PMID: 23666547     DOI: 10.1007/s10103-013-1344-z

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  23 in total

1.  An in vitro investigation of the temperature rises produced in dentine by Nd:YAG laser light with and without water cooling.

Authors:  A M Gow; A V McDonald; G J Pearson; D J Setchell
Journal:  Eur J Prosthodont Restor Dent       Date:  1999 Jun-Sep

2.  PULP RESPONSE TO EXTERNALLY APPLIED HEAT.

Authors:  L ZACH; G COHEN
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1965-04

3.  Laser ablation of dental tissues with picosecond pulses of 1.06-microm radiation transmitted through a hollow-core photonic-crystal fiber.

Authors:  Stanislav O Konorov; Vladimir P Mitrokhin; Andrei B Fedotov; Dmitrii A Sidorov-Biryukov; Valentin I Beloglazov; Nina B Skibina; Andrei V Shcherbakov; Ernst Wintner; Michael Scalora; Aleksei M Zheltikov
Journal:  Appl Opt       Date:  2004-04-10       Impact factor: 1.980

4.  Temperature response in the pulpal chamber of primary human teeth exposed to Nd:YAG laser using a picosecond pulsed regime.

Authors:  R F Z Lizarelli; L T Moriyama; V S Bagnato
Journal:  Photomed Laser Surg       Date:  2006-10       Impact factor: 2.796

5.  Influence of the degree of dentine mineralization on pulp chamber temperature increase during resin-based composite (RBC) light-activation.

Authors:  Eduardo Moreira da Silva; Alice Gonçalves Penelas; Michele Silveira Simão; Jaime Dutra Noronha Filho; Laiza Tatiana Poskus; José Guilherme Antunes Guimarães
Journal:  J Dent       Date:  2010-01-04       Impact factor: 4.379

6.  Periodontal laser surgery.

Authors:  J Russo
Journal:  Dent Today       Date:  1997-11

7.  High-speed scanning ablation of dental hard tissues with a λ = 9.3 μm CO2 laser: adhesion, mechanical strength, heat accumulation, and peripheral thermal damage.

Authors:  Daniel Nguyen; Kwang Chang; Saba Hedayatollahnajafi; Michal Staninec; Kenneth Chan; Robert Lee; Daniel Fried
Journal:  J Biomed Opt       Date:  2011-07       Impact factor: 3.170

Review 8.  Novel operative treatment options.

Authors:  D N J Ricketts; N B Pitts
Journal:  Monogr Oral Sci       Date:  2009-06-03

9.  Laser induced molar tooth pulp chamber temperature changes.

Authors:  I Anić; D Vidović; M Luić; M Tudja
Journal:  Caries Res       Date:  1992       Impact factor: 4.056

10.  Pulpal temperature increases with Er:YAG laser and high-speed handpieces.

Authors:  Bruno Neves Cavalcanti; José Luiz Lage-Marques; Sigmar Mello Rode
Journal:  J Prosthet Dent       Date:  2003-11       Impact factor: 3.426

View more
  9 in total

1.  Ultrashort pulsed laser conditioning of human enamel: in vitro study of the influence of geometrical processing parameters on shear bond strength of orthodontic brackets.

Authors:  M C Lorenzo; M Portillo; P Moreno; J Montero; A García; S E Santos-del Riego; A Albaladejo
Journal:  Lasers Med Sci       Date:  2013-11-19       Impact factor: 3.161

2.  Controlling dental enamel-cavity ablation depth with optimized stepping parameters along the focal plane normal using a three axis, numerically controlled picosecond laser.

Authors:  Fusong Yuan; Peijun Lv; Dangxiao Wang; Lei Wang; Yuchun Sun; Yong Wang
Journal:  Photomed Laser Surg       Date:  2015-02       Impact factor: 2.796

3.  Regulation and Measurement of the Heat Generated by Automatic Tooth Preparation in a Confined Space.

Authors:  Fusong Yuan; Jianqiao Zheng; Yuchun Sun; Yong Wang; Peijun Lyu
Journal:  Photomed Laser Surg       Date:  2017-06       Impact factor: 2.796

4.  Ablation of carious dental tissue using an ultrashort pulsed laser (USPL) system.

Authors:  Christoph Engelbach; Claudia Dehn; Christoph Bourauel; Jörg Meister; Matthias Frentzen
Journal:  Lasers Med Sci       Date:  2014-05-28       Impact factor: 3.161

5.  Thermotransduction and heat stress in dental structures during orthodontic debonding : Effectiveness of various cooling strategies.

Authors:  Philipp Kley; Matthias Frentzen; Katharina Küpper; Andreas Braun; Susann Kecsmar; Andreas Jäger; Michael Wolf
Journal:  J Orofac Orthop       Date:  2016-04-21       Impact factor: 1.938

6.  Effect of simulated pulpal fluid circulation on intrapulpal temperature following irradiation with an Nd:YVO4 laser.

Authors:  Andreas Braun; Susann Kecsmar; Felix Krause; Michael Berthold; Matthias Frentzen; Roland Frankenberger; Florian Schelle
Journal:  Lasers Med Sci       Date:  2014-02-28       Impact factor: 3.161

7.  Ablation Precision and Thermal Effects of a Picosecond Infrared Laser (PIRL) on Roots of Human Teeth: A Pilot Study Ex Vivo.

Authors:  Reinhard E Friedrich; Maria Quade; Nate Jowett; Peter Kroetz; Michael Amling; Felix K Kohlrusch; Jozef Zustin; Martin Gosau; Hartmut SchlÜter; R J Dwayne Miller
Journal:  In Vivo       Date:  2020 Sep-Oct       Impact factor: 2.155

8.  Method to control depth error when ablating human dentin with numerically controlled picosecond laser: a preliminary study.

Authors:  Yuchun Sun; Fusong Yuan; Peijun Lv; Dangxiao Wang; Lei Wang; Yong Wang
Journal:  Lasers Med Sci       Date:  2014-06-03       Impact factor: 3.161

9.  Temperatures in the pulpal cavity during orthodontic bonding using an LED light curing unit : An in vitro pilot study.

Authors:  Anna-Lena Groddeck; Rainer Schwestka-Polly; Hartmut Hecker; Michael Sostmann
Journal:  J Orofac Orthop       Date:  2020-09-01       Impact factor: 1.938

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.