Literature DB >> 23664750

Achieving fixation in glenoids with superior wear using reverse shoulder arthroplasty.

Christopher P Roche1, Nicholas J Stroud, Brian L Martin, Cindy A Steiler, Pierre-Henri Flurin, Thomas W Wright, Joseph D Zuckerman, Matthew J Dipaola.   

Abstract

BACKGROUND: Superior glenoid wear is a common challenge with reverse shoulder arthroplasty and, if left uncorrected, can result in superior glenoid tilt, which increases the risk of aseptic glenoid loosening. This study evaluates the impact of an E2 superior defect on reverse shoulder glenoid fixation in composite scapulae after correction of glenoid tilt by use of 2 different glenoid reaming techniques: eccentric reaming and off-axis reaming.
MATERIALS AND METHODS: A superior glenoid defect was created in 14 composite scapulae. The superior defect was corrected by 2 different glenoid reaming techniques: (1) eccentric reaming with implantation of a standard glenoid baseplate and (2) off-axis reaming with implantation of a superior-augment glenoid baseplate. Each corrected superior-defect scapula was then cyclically loaded (along with a control group consisting of 7 non-worn scapulae) for 10,000 cycles at 750 N; glenoid baseplate displacement was measured for each group to quantify fixation before and after cyclic loading.
RESULTS: Regardless of the glenoid reaming technique or the glenoid baseplate type, each standard and superior-augment glenoid baseplate remained well fixed in this superior-defect model scenario after cyclic loading. No differences in baseplate displacement were observed either before or after cyclic loading between groups. DISCUSSION: Our results suggest that either glenoid reaming technique may be used to achieve fixation in the clinically challenging situation of superior wear with reverse shoulder arthroplasty. LEVEL OF EVIDENCE: Basic science, biomechanical study.
Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

Entities:  

Keywords:  Basic Science; Biomechanical Study; Reverse shoulder arthroplasty; glenoid fixation

Mesh:

Year:  2013        PMID: 23664750     DOI: 10.1016/j.jse.2013.03.008

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  4 in total

1.  Posterior glenoid wear in total shoulder arthroplasty: eccentric anterior reaming is superior to posterior augment.

Authors:  Tim Wang; Geoffrey D Abrams; Anthony W Behn; Derek Lindsey; Nicholas Giori; Emilie V Cheung
Journal:  Clin Orthop Relat Res       Date:  2015-08-05       Impact factor: 4.176

2.  Reverse Total Shoulder Arthroplasty Baseplate Stability in Superior Bone Loss With Augmented Implant.

Authors:  Elise J Martin; Thomas R Duquin; Mark T Ehrensberger
Journal:  J Shoulder Elb Arthroplast       Date:  2021-06-13

Review 3.  Reverse Shoulder Arthroplasty Biomechanics.

Authors:  Christopher P Roche
Journal:  J Funct Morphol Kinesiol       Date:  2022-01-19

4.  Impact of screw length and screw quantity on reverse total shoulder arthroplasty glenoid fixation for 2 different sizes of glenoid baseplates.

Authors:  Christopher Roche; Caitlin DiGeorgio; Jose Yegres; Jennifer VanDeven; Nick Stroud; Pierre-Henri Flurin; Thomas Wright; Emilie Cheung; Joseph D Zuckerman
Journal:  JSES Open Access       Date:  2019-11-01