Deva D Chan1, Corey P Neu. 1. Weldon School of Biomedical Engineering, College of Engineering, Purdue University, West Lafayette, Indiana, USA.
Abstract
PURPOSE: Noninvasive assessment of tissue mechanical behavior could enable insights into tissue function in healthy and diseased conditions and permit the development of effective tissue repair treatments. Measurement of displacements under applied loading with MRI (dualMRI) has the potential for such biomechanical characterization on a clinical MRI system. METHODS: dualMRI was translated from high-field research systems to a 3T clinical system. Precision was calculated using repeated tests of a silicone phantom. dualMRI was demonstrated by visualizing displacements and strains in an intervertebral disc and compared to T2 measured during cyclic loading. RESULTS: The displacement and strain precisions were 24 µm and 0.3% strain, respectively, under the imaging parameters used in this study. Displacements and strains were measured within the intervertebral disc, but no correlations were found with the T2 values. CONCLUSION: The translation of dualMRI to a 3T system unveils the potential for in vivo studies in a myriad of tissue and organ systems. Because of the importance of mechanical behavior to the function of a variety of tissues, it's expected that dualMRI implemented on a clinical system will be a powerful tool in assessing the interlinked roles of structure, mechanics, and function in both healthy and diseased tissues.
PURPOSE: Noninvasive assessment of tissue mechanical behavior could enable insights into tissue function in healthy and diseased conditions and permit the development of effective tissue repair treatments. Measurement of displacements under applied loading with MRI (dualMRI) has the potential for such biomechanical characterization on a clinical MRI system. METHODS: dualMRI was translated from high-field research systems to a 3T clinical system. Precision was calculated using repeated tests of a silicone phantom. dualMRI was demonstrated by visualizing displacements and strains in an intervertebral disc and compared to T2 measured during cyclic loading. RESULTS: The displacement and strain precisions were 24 µm and 0.3% strain, respectively, under the imaging parameters used in this study. Displacements and strains were measured within the intervertebral disc, but no correlations were found with the T2 values. CONCLUSION: The translation of dualMRI to a 3T system unveils the potential for in vivo studies in a myriad of tissue and organ systems. Because of the importance of mechanical behavior to the function of a variety of tissues, it's expected that dualMRI implemented on a clinical system will be a powerful tool in assessing the interlinked roles of structure, mechanics, and function in both healthy and diseased tissues.
Authors: Jonathon H Yoder; John M Peloquin; Gang Song; Nick J Tustison; Sung M Moon; Alexander C Wright; Edward J Vresilovic; James C Gee; Dawn M Elliott Journal: J Biomech Eng Date: 2014-11 Impact factor: 2.097
Authors: Amy A Claeson; Edward J Vresilovic; Brent L Showalter; Alexander C Wright; James C Gee; Neil R Malhotra; Dawn M Elliott Journal: J Biomech Eng Date: 2019-05-29 Impact factor: 2.097
Authors: Brent L Showalter; John F DeLucca; John M Peloquin; Daniel H Cortes; Jonathon H Yoder; Nathan T Jacobs; Alexander C Wright; James C Gee; Edward J Vresilovic; Dawn M Elliott Journal: J Orthop Res Date: 2016-01-08 Impact factor: 3.494
Authors: John T Martin; Alexander B Oldweiler; Andrzej S Kosinski; Charles E Spritzer; Brian J Soher; Melissa M Erickson; Adam P Goode; Louis E DeFrate Journal: Eur Spine J Date: 2022-01-24 Impact factor: 2.721
Authors: Ephraim I Ben-Abraham; Jun Chen; Joel P Felmlee; Phil Rossman; Armando Manduca; Kai-Nan An; Richard L Ehman Journal: Magn Reson Imaging Date: 2015-12-30 Impact factor: 2.546