Literature DB >> 23649128

The importance of commutability of reference materials used as calibrators: the example of ceruloplasmin.

Ingrid Zegers1, Robert Beetham, Thomas Keller, Joanna Sheldon, David Bullock, Finlay MacKenzie, Stefanie Trapmann, Hendrik Emons, Heinz Schimmel.   

Abstract

BACKGROUND: Different methods for ceruloplasmin tend to give different results in external quality assessment schemes. During the production of the certified reference material ERM-DA470k/IFCC discrepant measurement results were also found for ceruloplasmin measured with different methods, and consequently the protein could not be certified in the material.
METHODS: We performed a commutability study with 30 serum samples and the reference materials ERM-DA470, ERM-DA470k/IFCC, and ERM-DA472/IFCC, using 6 different methods. Data were analyzed according to the CLSI Guideline C53-A to assess whether the reference materials had the same behavior as the serum samples with respect to measurement results obtained with combinations of the methods used.
RESULTS: Measurement results from different methods showed a good linear correlation for the serum samples. ERM-DA470 showed marked noncommutability for certain combinations of methods. ERM-DA470k/IFCC and ERM-DA472/IFCC were commutable for more combinations of methods. The lack of commutability of ERM-DA470 for certain combinations of methods correlates with results from the UK National External Quality Assessment Service showing discrepancies between results from these methods. For serum stored in the presence of sodium azide the results from different methods are essentially equivalent.
CONCLUSIONS: Ceruloplasmin in ERM-DA470 is a fully documented example of a situation in which, due to lack of commutability, the use of a common material for calibration did not lead to harmonization .

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23649128     DOI: 10.1373/clinchem.2012.201954

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  6 in total

1.  IFCC Working Group Recommendations for Correction of Bias Caused by Noncommutability of a Certified Reference Material Used in the Calibration Hierarchy of an End-User Measurement Procedure.

Authors:  W Greg Miller; Jeffrey Budd; Neil Greenberg; Cas Weykamp; Harald Althaus; Heinz Schimmel; Mauro Panteghini; Vincent Delatour; Ferruccio Ceriotti; Thomas Keller; Douglas Hawkins; Chris Burns; Robert Rej; Johanna E Camara; Finlay MacKenzie; Eline van der Hagen; Hubert Vesper
Journal:  Clin Chem       Date:  2020-06-01       Impact factor: 8.327

2.  Automation of o-dianisidine assay for ceruloplasmin activity analyses: usefulness of investigation in Wilson's disease and in hepatic encephalopathy.

Authors:  Mariacristina Siotto; Patrizio Pasqualetti; Massimo Marano; Rosanna Squitti
Journal:  J Neural Transm (Vienna)       Date:  2014-03-25       Impact factor: 3.575

3.  Biomarkers for diagnosis of Wilson's disease.

Authors:  Aidan Ryan; Sarah J Nevitt; Orla Tuohy; Paul Cook
Journal:  Cochrane Database Syst Rev       Date:  2019-11-19

4.  Screening of Wilson's disease in a psychiatric population: difficulties and pitfalls. A preliminary study.

Authors:  Caroline Demily; François Parant; David Cheillan; Emmanuel Broussolle; Alice Pavec; Olivier Guillaud; Lioara Restier; Alain Lachaux; Muriel Bost
Journal:  Ann Gen Psychiatry       Date:  2017-04-04       Impact factor: 3.455

5.  Feasibility study of a candidate reference material for ions in PM2.5: does commutability matter also for inorganic matrices?

Authors:  G Emma; J Snell; J Charoud-Got; A Held; H Emons
Journal:  Anal Bioanal Chem       Date:  2018-07-04       Impact factor: 4.142

Review 6.  Agricultural Use of Copper and Its Link to Alzheimer's Disease.

Authors:  Fábio C Coelho; Rosanna Squitti; Mariacarla Ventriglia; Giselle Cerchiaro; João P Daher; Jaídson G Rocha; Mauro C A Rongioletti; Anna-Camilla Moonen
Journal:  Biomolecules       Date:  2020-06-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.