Literature DB >> 23647752

Plan of the day selection for online image-guided adaptive post-prostatectomy radiotherapy.

Suki Gill1, Daniel Pham, Kim Dang, Mathias Bressel, Tomas Kron, Shankar Siva, Phillip K Tran, Keen Hun Tai, Farshad Foroudi.   

Abstract

PURPOSE: To compare the cone-beam CT (CBCT) soft tissue localization disparity between radiation oncologists (RO) and radiation therapy technologists (RTT) in a novel online protocol of image-guided adaptive radiotherapy to the postoperative prostate bed.
METHOD: Using the planning CT and pre-treatment CBCTs from the first week of radiotherapy, four adaptive plans of different sizes were derived for each of eight post-prostatectomy patients. Four ROs collectively defined the reference answer, i.e. the plan of the day and isocentre correction for 40 CBCTs taken in weeks 2-6 of treatment for each patient. RTTs were randomly assigned five of these CBCTs; and asked to record their plan of the day selection and isocentre correction. RTT selection and reference answers were compared. The distance between the RTT selection and the reference answer was calculated.
RESULTS: A total of 33 RTTs took part in this study. The average difference in CTV volume (reference answer-RTT selection) was 1.32 cm(3) (SD 29 cm(3)) overall. The average difference between reference answer and RTT isocentre coordinates was SI 1mm (SD 4.8mm), LR 1.1mm (SD 4.0mm) and AP -0.2mm (SD 3.9 mm). Distance of superior 8mm, inferior 6mm, left 4mm, right 2mm, anterior 6mm and posterior 6mm covered 100% of the CTV in 90% of fractions.
CONCLUSION: The difference between RTT and RO selection of adaptive volumes is small and can be accounted for in a clinically acceptable CTV to PTV margin. Adaptive post-prostatectomy radiotherapy is feasible, in the setting of an academic center although at the moment, we have insufficient evidence to suggest that margins can yet be reduced with IGART with the current protocol. Crown
Copyright © 2013. Published by Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23647752     DOI: 10.1016/j.radonc.2013.04.005

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  1 in total

1.  Automated replication of cone beam CT-guided treatments in the Pinnacle(3) treatment planning system for adaptive radiotherapy.

Authors:  Catriona Hargrave; Nicole Mason; Robyn Guidi; Julie-Anne Miller; Jillian Becker; Matthew Moores; Kerrie Mengersen; Michael Poulsen; Fiona Harden
Journal:  J Med Radiat Sci       Date:  2015-10-03
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.