Mechanism of cardiac defibrillation in open-chest dogs with unipolar DC-coupled simultaneous activation and shock potential recordings.

F X Witkowski1, P A Penkoske, R Plonsey.   

Abstract

The automatic implantable cardioverter-defibrillator has been shown to dramatically improve survival. The future refinement of these devices requires a clear understanding of their mechanism of action. We performed the following study to test two hypotheses: 1) When defibrillation is successful, fibrillating activity must be annihilated in a critical mass of both ventricles; and 2) when defibrillation is unsuccessful, at least one area of the ventricular mass has been left fibrillating. Unipolar Ag/AgCl sintered electrodes were directly coupled from triangular arrays at 40 epicardial locations (total, 120 recording sites) that covered both right and left ventricular surfaces and were designed to measure the voltage gradient generated by the shock at each triangular array as well as the underlying myocardial electrical activity before and immediately after the shock. An algorithm was developed and tested that reliably scored whether a postshock activation was a continuation of the immediately previous fibrillating activity. This technique was applied to 203 defibrillation attempts in six open-chest dogs during electrically induced ventricular fibrillation. There were 139 successful defibrillation attempts and 64 unsuccessful attempts. Monophasic truncated exponential 10-msec defibrillation shocks (0.5-35 J) were delivered through an anodal patch on the right atrium and a cathodal patch on the left ventricular apex. In all cases of unsuccessful defibrillation, at least one ventricular site could be clearly identified that failed to be defibrillated. In cases of successful defibrillation two distinct patterns were observed: 1) complete annihilation of fibrillating activity at all sites or 2) nearly complete cessation of fibrillating activity with a single area of persistent fibrillation that subsequently self-extinguished within one to three activations. This single site in the second form of successful defibrillation was located in the region of minimum voltage gradient produced by the defibrillating waveform and was occasionally accompanied by dynamic encapsulation with refractory tissue as a result of a wavefront emanating from a region that had undergone successful defibrillation. These results support the hypothesis that a critical mass of myocardium must be affected for successful defibrillation and that unsuccessful defibrillation is always accompanied by residual fibrillating activity in at least one site. The results also demonstrate that the size of the critical mass required for successful defibrillation can be less than 100%.

Entities:  

Mesh:

Year:  1990        PMID: 2364513     DOI: 10.1161/01.cir.82.1.244

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  10 in total

1.  Design and use of an "optrode" for optical recordings of cardiac action potentials.

Authors:  M Neunlist; S Z Zou; L Tung
Journal:  Pflugers Arch       Date:  1992-04       Impact factor: 3.657

2.  One-dimensional model of cardiac defibrillation.

Authors:  R Plonsey; R C Barr; F X Witkowski
Journal:  Med Biol Eng Comput       Date:  1991-09       Impact factor: 2.602

3.  Single capacitive discharge utilizing an auxiliary shock in the coronary venous system reduces the defibrillation threshold.

Authors:  P R Roberts; Y Zhang; S Zhuan; K A Mowrey; D W Wallick; D G Hills; T R Betts; S Allen; J Ewert; T N Mazgalev; J M Morgan
Journal:  J Interv Card Electrophysiol       Date:  2001-12       Impact factor: 1.900

4.  A biophysical model for defibrillation of cardiac tissue.

Authors:  J P Keener; A V Panfilov
Journal:  Biophys J       Date:  1996-09       Impact factor: 4.033

5.  Chronaxie of defibrillation: a pathway toward further optimization of defibrillation waveform?

Authors:  Igor R Efimov
Journal:  J Cardiovasc Electrophysiol       Date:  2008-10-14

6.  [Mechanisms of electrical defibrillation].

Authors:  S Reek; R E Ideker
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-03

7.  Comparison of coronary venous defibrillation with conventional transvenous internal defibrillation in man.

Authors:  P R Roberts; J R Paisey; T R Betts; S Allen; T Whitman; M Bonner; J M Morgan
Journal:  J Interv Card Electrophysiol       Date:  2003-02       Impact factor: 1.900

8.  Right ventricular insertion promotes reinitiation of ventricular fibrillation in defibrillation failure.

Authors:  Kenichi Iijima; Hanyu Zhang; Matthew T Strachan; Jian Huang; Gregory P Walcott; Jack M Rogers
Journal:  Heart Rhythm       Date:  2021-01-26       Impact factor: 6.779

9.  Extended charge banking model of dual path shocks for implantable cardioverter defibrillators.

Authors:  Derek J Dosdall; James D Sweeney
Journal:  Biomed Eng Online       Date:  2008-08-01       Impact factor: 2.819

10.  Optogenetics design of mechanistically-based stimulation patterns for cardiac defibrillation.

Authors:  Claudia Crocini; Cecilia Ferrantini; Raffaele Coppini; Marina Scardigli; Ping Yan; Leslie M Loew; Godfrey Smith; Elisabetta Cerbai; Corrado Poggesi; Francesco S Pavone; Leonardo Sacconi
Journal:  Sci Rep       Date:  2016-10-17       Impact factor: 4.379