Cross-contamination and cross-infection risk of otoscope heads.

Hakan Korkmaz1, Yeliz Cetinkol, Mukadder Korkmaz.   

Abstract

Adequate disinfection level of the medical equipments should be maintained to prevent cross-contamination between patients. Otoscope specula are usually cleaned and disinfected appropriately after each use by disinfectant solutions. However, since otoscope heads are electrical instruments with irregular inner surface they may still harbor pathogenic microorganisms. According to manufacturers' instructions, otoscope heads can be cleaned externally with a damp cloth and they can be disinfected with aldehydes, tensides, and alcohols. Instrument heads should not be placed in liquids. Alcohols cannot be used on glass surfaces. How often an otoscope head must be cleaned to limit contamination is not well established. This study aimed to determine whether the otoscope heads harbor pathogenic microorganisms or not. A total of 53 otoscope heads were included in the study. Swab samples were obtained from the inner parts of the otoscope heads. For bacteriological examination, cotton swabs were inoculated onto 5 % sheep blood agar, chocolate agar, and eosine methylene blue agar plates. For fungal evaluation, cotton swabs were inoculated onto Sabouraud dextrose agars. Cultured microorganisms were evaluated macroscopically and microscopically. Of the 53 otoscope heads, 22 were found to be contaminated with bacteria and/or fungi. Eleven of them were colonized by one organism, 11 were colonized by more than one organism. Only one Pseudomonas species isolated as gram-negative microorganism. Gram-positive microorganisms were isolated from the remaining 19 samples. Staphylococcus species were the most common bacteria isolated. The most common fungal isolates were Aspergillus species. Two cultures were positive with Candida albicans. The results show that decontamination of the otoscope heads is usually ignored. However, they can harbor considerable amount of pathogenic microorganisms. The probability of contamination and the risk of cross-infection is high if they are used by otolaryngologists. In order to prevent cross-contamination between patients, guidelines indicating appropriate methods and frequency of cleaning and disinfection of otoscope heads needed to be described.

Entities:  

Mesh:

Year:  2013        PMID: 23644940     DOI: 10.1007/s00405-013-2539-4

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  8 in total

1.  Patient-to-patient transmission of hepatitis C virus during colonoscopy.

Authors:  J P Bronowicki; V Venard; C Botté; N Monhoven; I Gastin; L Choné; H Hudziak; B Rihn; C Delanoë; A LeFaou; M A Bigard; P Gaucher; B Rhin
Journal:  N Engl J Med       Date:  1997-07-24       Impact factor: 91.245

2.  Contamination of an endoscope due to Trichosporon beigelli.

Authors:  S Singh; N Singh; R Kochhar; S K Mehta; P Talwar
Journal:  J Hosp Infect       Date:  1989-07       Impact factor: 3.926

3.  Endoscopic transmission of hepatitis B virus.

Authors:  G G Birnie; E M Quigley; G B Clements; E A Follet; G Watkinson
Journal:  Gut       Date:  1983-02       Impact factor: 23.059

4.  Transmission of Trichosporon asahii oesophagitis by a contaminated endoscope.

Authors:  C Lo Passo; I Pernice; A Celeste; G Perdichizzi; F Todaro-Luck
Journal:  Mycoses       Date:  2001       Impact factor: 4.377

5.  Outbreak of vancomycin-resistant enterococci in a burn unit.

Authors:  P S Falk; J Winnike; C Woodmansee; M Desai; C G Mayhall
Journal:  Infect Control Hosp Epidemiol       Date:  2000-09       Impact factor: 3.254

6.  [Iatrogenic Candida infection in pancreatic pseudocyst].

Authors:  L Frommeyer; P Bihl; H A Schmidt-Wilcke
Journal:  Z Gastroenterol       Date:  1991-08       Impact factor: 2.000

7.  Role of environmental contamination as a risk factor for acquisition of vancomycin-resistant enterococci in patients treated in a medical intensive care unit.

Authors:  José A Martínez; Robin Ruthazer; Karen Hansjosten; Laurie Barefoot; David R Snydman
Journal:  Arch Intern Med       Date:  2003-09-08

Review 8.  Healthcare equipment as a source of nosocomial infection: a systematic review.

Authors:  S Schabrun; L Chipchase
Journal:  J Hosp Infect       Date:  2006-03-03       Impact factor: 3.926

  8 in total
  1 in total

1.  Flashlight contamination and effectiveness of two disinfectants in a stomatology hospital.

Authors:  Dongye Yang; Liting Lin; Penghao Guo; Weina Zhang; Xingfang He; Qiuyu Huang; Longhui Lai; Weiqing Long
Journal:  Int J Nurs Sci       Date:  2017-03-27
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.