Literature DB >> 23643056

Acoustic waves in medical imaging and diagnostics.

Armen P Sarvazyan1, Matthew W Urban, James F Greenleaf.   

Abstract

Up until about two decades ago acoustic imaging and ultrasound imaging were synonymous. The term ultrasonography, or its abbreviated version sonography, meant an imaging modality based on the use of ultrasonic compressional bulk waves. Beginning in the 1990s, there started to emerge numerous acoustic imaging modalities based on the use of a different mode of acoustic wave: shear waves. Imaging with these waves was shown to provide very useful and very different information about the biological tissue being examined. We discuss the physical basis for the differences between these two basic modes of acoustic waves used in medical imaging and analyze the advantages associated with shear acoustic imaging. A comprehensive analysis of the range of acoustic wavelengths, velocities and frequencies that have been used in different imaging applications is presented. We discuss the potential for future shear wave imaging applications.
Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23643056      PMCID: PMC3682421          DOI: 10.1016/j.ultrasmedbio.2013.02.006

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  139 in total

1.  MR elastography of the prostate: initial in-vivo application.

Authors:  J Kemper; R Sinkus; J Lorenzen; C Nolte-Ernsting; A Stork; G Adam
Journal:  Rofo       Date:  2004-08

2.  Application of 1-D transient elastography for the shear modulus assessment of thin-layered soft tissue: comparison with supersonic shear imaging technique.

Authors:  Javier Brum; Jean-Luc Gennisson; Thu-Mai Nguyen; Nicolas Benech; Mathias Fink; Mickael Tanter; Carlos Negreira
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-04       Impact factor: 2.725

3.  In vivo mapping of brain elasticity in small animals using shear wave imaging.

Authors:  Emilie Macé; Ivan Cohen; Gabriel Montaldo; Richard Miles; Mathias Fink; Mickael Tanter
Journal:  IEEE Trans Med Imaging       Date:  2010-09-27       Impact factor: 10.048

4.  Noninvasive assessment of the rheological behavior of human organs using multifrequency MR elastography: a study of brain and liver viscoelasticity.

Authors:  Dieter Klatt; Uwe Hamhaber; Patrick Asbach; Jürgen Braun; Ingolf Sack
Journal:  Phys Med Biol       Date:  2007-11-23       Impact factor: 3.609

5.  Noninvasive method for estimation of complex elastic modulus of arterial vessels.

Authors:  Xiaoming Zhang; Randall R Kinnick; Mostafa Fatemi; James F Greenleaf
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-04       Impact factor: 2.725

6.  Pulse wave imaging for noninvasive and quantitative measurement of arterial stiffness in vivo.

Authors:  Jonathan Vappou; Jianwen Luo; Elisa E Konofagou
Journal:  Am J Hypertens       Date:  2010-01-21       Impact factor: 2.689

7.  Tissue response to mechanical vibrations for "sonoelasticity imaging".

Authors:  K J Parker; S R Huang; R A Musulin; R M Lerner
Journal:  Ultrasound Med Biol       Date:  1990       Impact factor: 2.998

8.  Detection of intrarenal microstructural changes with supersonic shear wave elastography in rats.

Authors:  Marc Derieppe; Yahsou Delmas; Jean-Luc Gennisson; Colette Deminière; Sandrine Placier; Mickaël Tanter; Christian Combe; Nicolas Grenier
Journal:  Eur Radiol       Date:  2011-08-16       Impact factor: 5.315

9.  A Review of Shearwave Dispersion Ultrasound Vibrometry (SDUV) and its Applications.

Authors:  Matthew W Urban; Shigao Chen; Mostafa Fatemi
Journal:  Curr Med Imaging Rev       Date:  2012-02-01

10.  A meta-analysis of transient elastography for the detection of hepatic fibrosis.

Authors:  Justin Stebbing; Lavanta Farouk; George Panos; Mike Anderson; Long R Jiao; Sundhiya Mandalia; Mark Bower; Brian Gazzard; Mark Nelson
Journal:  J Clin Gastroenterol       Date:  2010-03       Impact factor: 3.062

View more
  31 in total

1.  Magnetomotive optical coherence elastography for microrheology of biological tissues.

Authors:  Vasilica Crecea; Adeel Ahmad; Stephen A Boppart
Journal:  J Biomed Opt       Date:  2013-12       Impact factor: 3.170

2.  External vibration multi-directional ultrasound shearwave elastography (EVMUSE): application in liver fibrosis staging.

Authors:  Heng Zhao; Pengfei Song; Duane D Meixner; Randall R Kinnick; Matthew R Callstrom; William Sanchez; Matthew W Urban; Armando Manduca; James F Greenleaf; Shigao Chen
Journal:  IEEE Trans Med Imaging       Date:  2014-07-09       Impact factor: 10.048

3.  Analysis and measurement of the modulation transfer function of harmonic shear wave induced phase encoding imaging.

Authors:  Stephen A McAleavey
Journal:  J Acoust Soc Am       Date:  2014-05       Impact factor: 1.840

4.  Multifunctional composites for elastic and electromagnetic wave propagation.

Authors:  Jaeuk Kim; Salvatore Torquato
Journal:  Proc Natl Acad Sci U S A       Date:  2020-04-09       Impact factor: 11.205

5.  Ultrasound for the treatment of acute kidney injury and other inflammatory conditions: a promising path toward noninvasive neuroimmune regulation.

Authors:  Jieru Cai; William T Nash; Mark D Okusa
Journal:  Am J Physiol Renal Physiol       Date:  2020-06-08

Review 6.  [Quantitative methods in sonography].

Authors:  K-V Jenderka; S Delorme
Journal:  Radiologe       Date:  2019-11       Impact factor: 0.635

Review 7.  Magnetic resonance elastography of abdomen.

Authors:  Sudhakar Kundapur Venkatesh; Richard L Ehman
Journal:  Abdom Imaging       Date:  2015-04

8.  In Vivo Open- and Closed-chest Measurements of Left-Ventricular Myocardial Viscoelasticity using Lamb wave Dispersion Ultrasound Vibrometry (LDUV): A Feasibility Study.

Authors:  Ivan Z Nenadic; Matthew W Urban; Cristina Pislaru; Daniel Escobar; Luiz Vasconcelos; James F Greenleaf
Journal:  Biomed Phys Eng Express       Date:  2018-04-30

9.  Sparse matrix beamforming and image reconstruction for 2-D HIFU monitoring using harmonic motion imaging for focused ultrasound (HMIFU) with in vitro validation.

Authors:  Gary Y Hou; Jean Provost; Julien Grondin; Shutao Wang; Fabrice Marquet; Ethan Bunting; Elisa E Konofagou
Journal:  IEEE Trans Med Imaging       Date:  2014-06-20       Impact factor: 10.048

10.  Estimation of Shear Wave Speed in the Rhesus Macaques' Uterine Cervix.

Authors:  Bin Huang; Lindsey Carlson Drehfal; Ivan M Rosado-Mendez; Quinton W Guerrero; Mark L Palmeri; Heather A Simmons; Helen Feltovich; Timothy J Hall
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-02-08       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.