Literature DB >> 23641284

Exercise-ankle brachial pressure index with one-minute treadmill walking in patients on maintenance hemodialysis.

Kazuo Tsuyuki1, Kenji Kohno, Kunio Ebine, Takehiro Obara, Toshiyuki Aoki, Atsuhiko Muto, Kenji Ninomiya, Kenta Kumagai, Itaru Yokouchi, Yoshiyuki Yazaki, Shinichi Watanabe.   

Abstract

BACKGROUND: The ankle-brachial pressure index (ABI) is widely used as a standard screening method for arterial occlusive lesion above the knee. However, the sensitivity of ABI is low in hemodialysis (HD) patients. Exercise stress (Ex-ABI) may reduce the false negative results. PATIENTS AND METHODS: After measuring resting ABI and toe-brachial pressure index (TBI), ankle pressure and ABI immediately after walking (Post-AP, Post-ABI) were measured using one-minute treadmill walking in 52 lower limbs of 26 HD patients. The definition of peripheral arterial occlusive disease (PAD) required an ABI value of less than 0.90, TBI value of less than 0.60, and decrease of more than 15% of the Post-ABI value and 20 mmHg of Post-AP in Ex-ABI. Computed tomographic angiography (CTA) was performed in 32 lower limbs of 16 HD patients. PAD is defined as presence of stenosis of more than 75% in the case of lesions from an iliac artery to knee on CTA.
RESULTS: The accuracy of Ex-ABI (Sensitivity, 85.7%; Specificity, 77.7%) was higher than those of ABI (Sensitivity, 42.9%; Specificity, 83.3%) or TBI (Sensitivity, 78.6%; Specificity, 61.1%).
CONCLUSION: Ex-ABI with one-minute treadmill walking is the most useful tool for the screening of arterial occlusive lesions above the knee in maintenance HD patients.

Entities:  

Keywords:  diagnosis; exercise; hemodialysis; peripheral arterial disease; screening

Year:  2012        PMID: 23641284      PMCID: PMC3635000          DOI: 10.3400/avd.oa.12.00070

Source DB:  PubMed          Journal:  Ann Vasc Dis        ISSN: 1881-641X


  7 in total

1.  The prevalence of peripheral arterial disease and medial arterial calcification in patients with chronic renal failure: requirements for diagnostics.

Authors:  Yrjö Leskinen; Juha P Salenius; Terho Lehtimäki; Heini Huhtala; Heikki Saha
Journal:  Am J Kidney Dis       Date:  2002-09       Impact factor: 8.860

2.  Recommended standards for reports dealing with lower extremity ischemia: revised version.

Authors:  R B Rutherford; J D Baker; C Ernst; K W Johnston; J M Porter; S Ahn; D N Jones
Journal:  J Vasc Surg       Date:  1997-09       Impact factor: 4.268

3.  Comparison of standard one-minute treadmill exercise and strandness test (absolute walking distance) in relation to site of lesion, walking distance, and diastolic blood flow velocity (Doppler curves).

Authors:  R Fabry; J J Dubost; P Pochon; P Duchêne-Marullaz
Journal:  Angiology       Date:  1990-10       Impact factor: 3.619

Review 4.  Clinical trials for claudication. Assessment of exercise performance, functional status, and clinical end points. Vascular Clinical Trialists.

Authors:  W R Hiatt; A T Hirsch; J G Regensteiner; E P Brass
Journal:  Circulation       Date:  1995-08-01       Impact factor: 29.690

5.  Peripheral arterial occlusive disease is more prevalent in patients with hemodialysis: comparison with the findings of multidetector-row computed tomography.

Authors:  Koji Okamoto; Machiko Oka; Kyoko Maesato; Ryota Ikee; Tsutomu Mano; Hidekazu Moriya; Takayasu Ohtake; Shuzo Kobayashi
Journal:  Am J Kidney Dis       Date:  2006-08       Impact factor: 8.860

6.  Current status of noninvasive tests in the diagnosis of peripheral arterial disease.

Authors:  E F Bernstein; A Fronek
Journal:  Surg Clin North Am       Date:  1982-06       Impact factor: 2.741

7.  Standard exercise test to assess peripheral arterial disease.

Authors:  S P Laing; R M Greenhalgh
Journal:  Br Med J       Date:  1980-01-05
  7 in total
  2 in total

1.  Utility of Exercise-Induced Zero TBI Sign in Patients on Maintenance Hemodialysis.

Authors:  Kazuo Tsuyuki; Kenji Kohno; Kunio Ebine; Susumu Tamura; Yasuhiro Ohzeki; Toshifumi Murase; Takehiro Ohara; Yujin Kunugi; Fumihiko Iida; Yoshie Mochizuki; Mutsumi Sorimachi; Shinichi Watanabe
Journal:  Ann Vasc Dis       Date:  2016-08-23

2.  Comparison of Diagnostic Accuracy between Pulse Volume Recording Parameters and Exercise-Ankle-Brachial Pressure Index in Patients with Ankle-Brachial Pressure Index above 0.9.

Authors:  Kazuo Tsuyuki; Kenji Kohno; Miho Asaoka; Kunio Ebine; Susumu Tamura; Yasuhiro Ohzeki; Toshifumi Murase; Kaoru Sugi; Kenta Kumagai; Itaru Yokouchi; Kenji Yamazaki; Satoru Tohi; Mutsumi Sorimachi; Shinichi Watanabe
Journal:  Ann Vasc Dis       Date:  2016-11-25
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.