Literature DB >> 23639213

Is bigger better? A retrospective analysis of native renal biopsies with 16 Gauge versus 18 Gauge automatic needles.

Jun Mai1, Jim Yong, Hugh Dixson, Angela Makris, Ananthakrishnapuram Aravindan, Michael G Suranyi, Jeffrey Wong.   

Abstract

AIM: Percutaneous renal biopsy (PRB) remains the gold standard for the diagnosis of renal disease; however, the tissue yield which relates to the optimal needle size used for native-kidney biopsies has not been clearly established. Our study compares the sample adequacy and complication rates using 16 gauge (G) and 18 gauge (G) automatic needles on native kidney PRB.
METHODS: A retrospective analysis was performed of native-kidney biopsies at two centres, one exclusively using 16G and the other exclusively using 18G needles. All samples were assessed by a single centralized pathology service. We compared patient characteristics, indications, diagnoses, adequacy of tissue samples, and complications.
RESULTS: A total of 934 native-kidney biopsies were performed with real time ultrasound guidance: 753 with Bard Max Core 16G × 16 cm needles, and 181 with Bard Magnum 18G × 20 cm needles. The median (range) of total glomeruli count per biopsy was higher in the 16G group compared with the 18G group (19 (0-66) vs. 12 (0-35), P < 0.001), despite having fewer cores per biopsy (2 (0-4) vs. 3 (1-4), P < 0.001). The 16G group provided a greater proportion of adequate biopsy samples (94.7% vs. 89.4%, P = 0.001). There was no significant difference in the frequency of total complications between the 16G and 18G groups (3.7% vs. 2.2%, P = 0.49).
CONCLUSION: This retrospective study demonstrates 16G needles provide more glomeruli, more diagnostically adequate renal tissue, with fewer cores without a significant increase in complications compared with 18G needles. Based on these observations, 16G needles should be considered as the first line option in native-kidney PRB.
© 2013 The Authors. Nephrology © 2013 Asian Pacific Society of Nephrology.

Entities:  

Mesh:

Year:  2013        PMID: 23639213     DOI: 10.1111/nep.12093

Source DB:  PubMed          Journal:  Nephrology (Carlton)        ISSN: 1320-5358            Impact factor:   2.506


  16 in total

Review 1.  The Native Kidney Biopsy: Update and Evidence for Best Practice.

Authors:  Jonathan J Hogan; Michaela Mocanu; Jeffrey S Berns
Journal:  Clin J Am Soc Nephrol       Date:  2015-09-02       Impact factor: 8.237

2.  Evaluating renal biopsy-associated hemorrhage complications by the equation and providing an early intervention: a single-center experience.

Authors:  Chao Wang; Yang Yang; Liping Jin; Ying Zhang; Guanglei Chen; Zhuliang Zhou; Minghui Song; Qingman Gao; Changchun Li; Tao Pan; Fagui He; Lu Ma
Journal:  J Nephrol       Date:  2015-04-15       Impact factor: 3.902

Review 3.  Renal biopsy: Still a landmark for the nephrologist.

Authors:  Luca Visconti; Valeria Cernaro; Carlo Alberto Ricciardi; Viviana Lacava; Vincenzo Pellicanò; Antonio Lacquaniti; Michele Buemi; Domenico Santoro
Journal:  World J Nephrol       Date:  2016-07-06

4.  Increased risk of renal biopsy complications in patients with IgA-nephritis.

Authors:  Björn Peters; Bernd Stegmayr; Yvonne Andersson; Henrik Hadimeri; Johan Mölne
Journal:  Clin Exp Nephrol       Date:  2015-05-08       Impact factor: 2.801

5.  In Situ Classification of Cell Types in Human Kidney Tissue Using 3D Nuclear Staining.

Authors:  Andre Woloshuk; Suraj Khochare; Aljohara F Almulhim; Andrew T McNutt; Dawson Dean; Daria Barwinska; Michael J Ferkowicz; Michael T Eadon; Katherine J Kelly; Kenneth W Dunn; Mohammad A Hasan; Tarek M El-Achkar; Seth Winfree
Journal:  Cytometry A       Date:  2020-12-13       Impact factor: 4.714

6.  Accuracy of 16/18G core needle biopsy for ultrasound-visible breast lesions.

Authors:  Jie-Ying Zhou; Jie Tang; Zhi-Li Wang; Fa-Qin Lv; Yu-Kun Luo; Hong-Zhen Qin; Mei Liu
Journal:  World J Surg Oncol       Date:  2014-01-08       Impact factor: 2.754

7.  Needle guides enhance tissue adequacy and safety of ultrasound-guided renal biopsies.

Authors:  Namrata S Rao; Abhilash Chandra
Journal:  Kidney Res Clin Pract       Date:  2018-03-31

8.  An integrated pathology and ultrasonography-based simulation for training in performing kidney biopsy
.

Authors:  Shree G Sharma; John M Arthur; Stephen M Bonsib; Kevin D Phelan; Manisha Singh; Nithin Karakala; Kelly W Bulloch; Vandana Dua Niyyar; Juan Carlos Q Velez
Journal:  Clin Nephrol       Date:  2018-03       Impact factor: 0.975

9.  Adequacy and complication rates of percutaneous renal biopsy with 18- vs. 16-gauge needles in native kidneys in Chinese individuals.

Authors:  Weiji Xie; Jing Xu; Yi Xie; Zhijun Lin; Xiaochang Xu; Xialan Zhang; Yimin Zhang
Journal:  BMC Nephrol       Date:  2020-08-12       Impact factor: 2.388

10.  Comparison of native and transplant kidney biopsies: diagnostic yield and complications.

Authors:  William L Whittier; Casey Gashti; Samuel Saltzberg; Stephen Korbet
Journal:  Clin Kidney J       Date:  2018-07-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.