Electronic fetal monitoring in the United States: temporal trends and adverse perinatal outcomes.

Cande V Ananth1, Suneet P Chauhan, Han-Yang Chen, Mary E D'Alton, Anthony M Vintzileos.   

Abstract

OBJECTIVE: To examine trends in electronic fetal monitoring (EFM) use and quantify the extent to which such trends are associated with changes in rates of primary cesarean delivery and neonatal morbidity and mortality.
METHODS: We carried out a retrospective study of more than 55 million nonanomalous singleton live births (24-44 weeks of gestation) delivered in the United States between 1990 and 2004. Changes in the risks of neonatal mortality, cesarean delivery, and operative vaginal delivery for fetal distress, 5-minute Apgar score lower than 4, and neonatal seizures (at 34 weeks of gestation or after) were examined in relation to changes in EFM use.
RESULTS: Electronic fetal monitoring use increased from 73.4% in 1990 to 85.7% in 2004, a relative increase of 17% (95% confidence interval 16-18%). This increase was associated with an additional 5% and 2% decline in early and late neonatal deaths, respectively, at 24-33 weeks of gestation as well as a 4-7% additional decline in the 5-minute Apgar score lower than 4 at 24-33, 34-36, and 37-44 weeks of gestation. Increasing EFM use was associated with a 2-4% incremental increased rate of both cesarean delivery and operative vaginal delivery for fetal distress at 24-33, 34-36, and 37-44 weeks of gestation. Increasing EFM was not associated with any temporal changes in the rate of neonatal seizures.
CONCLUSIONS: The temporal increase in EFM use in the United States appears to be modestly associated with the recent declines in neonatal mortality, especially at preterm gestations. LEVEL OF EVIDENCE: II.

Entities:  

Mesh:

Year:  2013        PMID: 23635727     DOI: 10.1097/AOG.0b013e318289510d

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  9 in total

1.  A prospective cohort study of fetal heart rate monitoring: deceleration area is predictive of fetal acidemia.

Authors:  Alison G Cahill; Methodius G Tuuli; Molly J Stout; Julia D López; George A Macones
Journal:  Am J Obstet Gynecol       Date:  2018-02-01       Impact factor: 8.661

2.  Electronic fetal monitoring, cerebral palsy, and caesarean section: assumptions versus evidence.

Authors:  Karin B Nelson; Thomas P Sartwelle; Dwight J Rouse
Journal:  BMJ       Date:  2016-12-01

3.  Gestational diabetes in the United States: temporal changes in prevalence rates between 1979 and 2010.

Authors:  J A Lavery; A M Friedman; K M Keyes; J D Wright; C V Ananth
Journal:  BJOG       Date:  2016-08-11       Impact factor: 6.531

4.  Intrapartum Fetal Heart Rate Tracing Among Small-for-Gestational Age Compared With Appropriate-for-Gestational-Age Neonates.

Authors:  Suneet P Chauhan; Steven J Weiner; George R Saade; Michael A Belfort; Uma M Reddy; John M Thorp; Alan T N Tita; Russell S Miller; Mara J Dinsmoor; David S McKenna; Bradley Stetzer; Dwight J Rouse; Ronald S Gibbs; Yasser Y El-Sayed; Yoram Sorokin; Steve N Caritis
Journal:  Obstet Gynecol       Date:  2018-10       Impact factor: 7.661

5.  Cardiotocography in breech versus vertex delivery: an examiner-blinded, cross-sectional nested case-control study.

Authors:  Elli Toivonen; Outi Palomäki; Heini Huhtala; Jukka Uotila
Journal:  BMC Pregnancy Childbirth       Date:  2016-10-21       Impact factor: 3.007

6.  Linear Phase Sharp Transition BPF to Detect Noninvasive Maternal and Fetal Heart Rate.

Authors:  Niyan Marchon; Gourish Naik; K R Pai
Journal:  J Healthc Eng       Date:  2018-03-29       Impact factor: 2.682

7.  A Phonocardiographic-Based Fiber-Optic Sensor and Adaptive Filtering System for Noninvasive Continuous Fetal Heart Rate Monitoring.

Authors:  Radek Martinek; Jan Nedoma; Marcel Fajkus; Radana Kahankova; Jaromir Konecny; Petr Janku; Stanislav Kepak; Petr Bilik; Homer Nazeran
Journal:  Sensors (Basel)       Date:  2017-04-18       Impact factor: 3.576

8.  An Efficient and Robust Deep Learning Method with 1-D Octave Convolution to Extract Fetal Electrocardiogram.

Authors:  Khuong Vo; Tai Le; Amir M Rahmani; Nikil Dutt; Hung Cao
Journal:  Sensors (Basel)       Date:  2020-07-04       Impact factor: 3.576

9.  Automatic evaluation of progression angle and fetal head station through intrapartum echographic monitoring.

Authors:  Sergio Casciaro; Francesco Conversano; Ernesto Casciaro; Giulia Soloperto; Emanuele Perrone; Gian Carlo Di Renzo; Antonio Perrone
Journal:  Comput Math Methods Med       Date:  2013-09-09       Impact factor: 2.238

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.