Literature DB >> 23632783

The use of a dual-mobility concept in total hip arthroplasty patients with spastic disorders: no dislocations in a series of ten cases at midterm follow-up.

Rick J M Sanders1, Bart A Swierstra, Jon H M Goosen.   

Abstract

INTRODUCTION: Total hip arthroplasty (THA) is one of the treatment options in patients with cerebral palsy (CP) with painful osteoarthritis of the hip. However, the risk of dislocation of the prosthesis is higher in patients with CP when compared with physically normal patients. In this retrospective study of ten consecutive cases, we hypothesized that the use of a dual-mobility cup could reduce this risk of dislocation combined with good functional results.
MATERIALS AND METHODS: From January 2008 until October 2010, eight patients (ten hips) with CP who consecutively received a THA using a dual-mobility cup were identified. At the time of surgery, the average age of the patient group was 54 years (range 43-61). Latest follow-up took place after on average 39 months (range 22-56 months). All patients or their caregivers were interviewed by telephone. They were asked if dislocation of the prosthesis had occurred. To evaluate quality of life and health in general, patients completed the SF-36 questionnaire.
RESULTS: None of the prostheses had dislocated at the latest follow-up. Reoperation was needed in one patient after a periprosthetic fracture. Radiologic evaluation showed a mean cup inclination of 46 (range 27-58). On average, the quality of life of patients in this study was found to be limited in particular on the domains of physical health and functioning, while a fair to good score was measured at the six other different domains.
CONCLUSION: The use of a dual-mobility cup in THA in patients with CP can lead to favourable results with respect to dislocation and clinical outcome.

Entities:  

Mesh:

Year:  2013        PMID: 23632783     DOI: 10.1007/s00402-013-1759-9

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  13 in total

Review 1.  The evolution of outcomes and indications for the dual-mobility cup: a systematic review.

Authors:  Cécile Batailler; Camdon Fary; Régis Verdier; Thierry Aslanian; Jacques Caton; Sebastien Lustig
Journal:  Int Orthop       Date:  2016-12-21       Impact factor: 3.075

Review 2.  Dual-mobility arthroplasty failure: a rationale review of causes and technical considerations for revision.

Authors:  Philippe Hernigou; Arnaud Dubory; Damien Potage; François Roubineau; Charles Henri Flouzat Lachaniette
Journal:  Int Orthop       Date:  2016-11-21       Impact factor: 3.075

Review 3.  Dual Mobility in Total Hip Arthroplasty: Biomechanics, Indications and Complications-Current Concepts.

Authors:  Nilesh Patil; Prashant Deshmane; Ajit Deshmukh; Christopher Mow
Journal:  Indian J Orthop       Date:  2021-10-13       Impact factor: 1.033

Review 4.  Dual mobility cups in total hip arthroplasty.

Authors:  Ivan De Martino; Georgios Konstantinos Triantafyllopoulos; Peter Keyes Sculco; Thomas Peter Sculco
Journal:  World J Orthop       Date:  2014-07-18

5.  Good outcome of total hip replacement in patients with cerebral palsy: A comparison of 389 patients and 425,813 controls from the National Joint Registry for England and Wales.

Authors:  Garry King; Linda P Hunt; J Mark Wilkinson; Ashley W Blom
Journal:  Acta Orthop       Date:  2016-02-10       Impact factor: 3.717

6.  No dislocations after primary hip arthroplasty with the dual mobility cup in displaced femoral neck fracture in patients with dementia. A one-year follow-up in 20 patients.

Authors:  Anders Elneff Graversen; Stig Storgaard Jakobsen; Pia Kjær Kristensen; Theis Muncholm Thillemann
Journal:  SICOT J       Date:  2017-02-10

7.  Early Intraprosthetic Dislocation of a Dual Mobility Acetabular Construct after Total Hip Arthroplasty.

Authors:  Vineet Tyagi; Oluwaseun Akinbo
Journal:  J Orthop Case Rep       Date:  2017 Mar-Apr

8.  Constrained liners, dual mobility or large diameter heads to avoid dislocation in THA.

Authors:  Olivier Guyen
Journal:  EFORT Open Rev       Date:  2017-03-13

9.  Risk factors and modes of failure in the modern dual mobility implant. A systematic review and meta-analysis.

Authors:  Fu-Yuan Pai; Hsuan-Hsiao Ma; Te-Feng Arthur Chou; Tsan-Wen Huang; Kuo-Chin Huang; Shang-Wen Tsai; Cheng-Fong Chen; Wei-Ming Chen
Journal:  BMC Musculoskelet Disord       Date:  2021-06-14       Impact factor: 2.362

10.  Dual mobility acetabular component in revision total hip arthroplasty for persistent dislocation: no dislocations in 50 hips after 1-5 years.

Authors:  M van Heumen; P J C Heesterbeek; B A Swierstra; G G Van Hellemondt; J H M Goosen
Journal:  J Orthop Traumatol       Date:  2014-09-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.