Literature DB >> 23631522

The effect of probe to skin contact force on Cutometer MPA 580 measurements.

James P Bonaparte1, David Ellis, Jeffson Chung.   

Abstract

The purpose of this study is to test the hypothesis that increasing the force applied on the skin by the Cutometer MP580 probe will result in a decrease in the skin elasticity measures. Specifically, this study assessed the probe intrinsic weight plus the addition of a light mass (10 g and 20 g), a moderate mass (50 g and 100 g) and a high mass (200 g and 500 g) on skin elasticity measures. Primary outcome measures Uv, Ur, Uf, Ue and Ua, along with calculated measures Uv/Uf, Ua/Uf and Ur/Uf were assessed under each loading condition. A general linear model ANOVA with repeated measures was used to assess for differences in each outcome measure between each loading condition. Thirty-two patients were enrolled and all completed the testing. For all primary variables except Uv (p < 0.001), there was no statistically significant effect of adding a light mass to the probe. There was a significant effect of the addition of a moderate and heavy mass for all variables (p < 0.005) except Ue/Uf. These results suggest that the addition of a low mass results in no significant effect on outcome measures. However, if moderate-to-heavy additional force is applied to the probe, the outcome measures are significantly altered. Of all the variables, Ue/Uf appears to be influenced the least by alterations in force. Users should ensure light contact is made between the skin and probe during testing to avoid a false alteration in outcome measures of skin elasticity.

Entities:  

Mesh:

Year:  2013        PMID: 23631522     DOI: 10.3109/03091902.2013.779325

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  11 in total

1.  A bioinspired stretchable membrane-based compliance sensor.

Authors:  Levent Beker; Naoji Matsuhisa; Insang You; Sarah Rachel Arussy Ruth; Simiao Niu; Amir Foudeh; Jeffrey B-H Tok; Xiaodong Chen; Zhenan Bao
Journal:  Proc Natl Acad Sci U S A       Date:  2020-05-08       Impact factor: 11.205

2.  Longitudinal monitoring and prediction of long-term outcome of scar stiffness on pediatric patients.

Authors:  Bettina Müller; Edoardo Mazza; Clemens Schiestl; Julia Elrod
Journal:  Burns Trauma       Date:  2021-09-30

3.  Effects of red ginseng on the elastic properties of human skin.

Authors:  Moon Young Park; Se Jik Han; Donggerami Moon; Sangwoo Kwon; Jin-Woo Lee; Kyung Sook Kim
Journal:  J Ginseng Res       Date:  2019-08-21       Impact factor: 6.060

4.  Assessment of Pliability and Elasticity of the External Nasal Skin in Patients With Unilateral Nasal Valve Collapse: A Static Biomechanical Evaluation.

Authors:  James P Bonaparte; Ross Campbell
Journal:  JAMA Facial Plast Surg       Date:  2018-12-01       Impact factor: 4.611

5.  Standardizing Dimensionless Cutometer Parameters to Determine In Vivo Elasticity of Human Skin.

Authors:  Darren B Abbas; Christopher V Lavin; Evan J Fahy; Michelle Griffin; Nicholas Guardino; Megan King; Kellen Chen; P Hermann Lorenz; Geoffrey C Gurtner; Michael T Longaker; Arash Momeni; Derrick C Wan
Journal:  Adv Wound Care (New Rochelle)       Date:  2021-10-08       Impact factor: 4.730

6.  Influence of therapeutic ultrasound on the biomechanical characteristics of the skin.

Authors:  Lígia Brancalion Catapani; Adriana da Costa Gonçalves; Nathalia Morano Candeloro; Lídia Aparecida Rossi; Elaine Caldeira de Oliveira Guirro
Journal:  J Ther Ultrasound       Date:  2016-08-17

7.  Biopharmaceutical Development of a Bifonazole Multiple Emulsion for Enhanced Epidermal Delivery.

Authors:  Joaquim Suñer-Carbó; Ana Calpena-Campmany; Lyda Halbaut-Bellowa; Beatriz Clares-Naveros; María José Rodriguez-Lagunas; Elena Barbolini; Joanna Zamarbide-Losada; Antonio Boix-Montañés
Journal:  Pharmaceutics       Date:  2019-02-02       Impact factor: 6.321

8.  Investigating the intra- and inter-rater reliability of a panel of subjective and objective burn scar measurement tools.

Authors:  K C Lee; A Bamford; F Gardiner; A Agovino; B Ter Horst; J Bishop; A Sitch; L Grover; A Logan; N S Moiemen
Journal:  Burns       Date:  2019-07-19       Impact factor: 2.744

9.  The effect of topically applied tissue expanders on radial forearm skin pliability: a prospective self-controlled study.

Authors:  Jeffson Chung; James P Bonaparte; Michael Odell; Martin Corsten
Journal:  J Otolaryngol Head Neck Surg       Date:  2014-04-16

10.  A novel ultra-light suction device for mechanical characterization of skin.

Authors:  Bettina Müller; Julia Elrod; Marco Pensalfini; Raoul Hopf; Oliver Distler; Clemens Schiestl; Edoardo Mazza
Journal:  PLoS One       Date:  2018-08-08       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.