Literature DB >> 1614315

Deblurring for non-2D Fourier transform magnetic resonance imaging.

D C Noll1, J M Pauly, C H Meyer, D G Nishimura, A Macovski.   

Abstract

For several non-2D Fourier transform imaging methods, off-resonant reconstruction does not just cause geometric distortion, but changes the shape of the point spread function and causes blurring. This effect is well known for projection reconstruction and spiral k-space scanning sequences. We introduce here a method that automatically removes blur introduced by magnetic field inhomogeneity and susceptibility without using a resonant frequency map, making these imaging methods more useful. In this method, the raw data are modulated to several different frequencies and reconstructed to create a series of base images. Determination of degree of blur is done by calculating a focusing measure for each point in each base image and a composite image is then constructed using only the unblurred regions from each base image. This method has been successfully applied to phantom and in vivo images using projection-reconstruction and spiral-scan sequences.

Mesh:

Year:  1992        PMID: 1614315     DOI: 10.1002/mrm.1910250210

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  49 in total

1.  Three-dimensional tailored RF pulses for the reduction of susceptibility artifacts in T(*)(2)-weighted functional MRI.

Authors:  V A Stenger; F E Boada; D C Noll
Journal:  Magn Reson Med       Date:  2000-10       Impact factor: 4.668

2.  Advanced MRI of articular cartilage.

Authors:  Hillary J Braun; Garry E Gold
Journal:  Imaging Med       Date:  2011-10

3.  Multishot 3D slice-select tailored RF pulses for MRI.

Authors:  V Andrew Stenger; Fernando E Boada; Douglas C Noll
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

Review 4.  Magnetic resonance coronary angiography.

Authors:  Phillip C Yang; Michael V McConnell; Dwight G Nishimura; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2003-01       Impact factor: 2.931

5.  Variable-density spiral 3D tailored RF pulses.

Authors:  V Andrew Stenger; Fernando E Boada; Douglas C Noll
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

6.  Improvements in spiral MR imaging.

Authors:  P Börnert; H Schomberg; B Aldefeld; J Groen
Journal:  MAGMA       Date:  1999-10       Impact factor: 2.310

7.  High-resolution ultrashort echo time (UTE) imaging on human knee with AWSOS sequence at 3.0 T.

Authors:  Yongxian Qian; Ashley A Williams; Constance R Chu; Fernando E Boada
Journal:  J Magn Reson Imaging       Date:  2011-10-14       Impact factor: 4.813

Review 8.  Current trends and challenges in MRI acquisitions to investigate brain function.

Authors:  Bradley P Sutton; Cheng Ouyang; Dimitrios C Karampinos; Gregory A Miller
Journal:  Int J Psychophysiol       Date:  2009-02-21       Impact factor: 2.997

9.  A circular echo planar sequence for fast volumetric fMRI.

Authors:  Christoph Rettenmeier; Danilo Maziero; Yongxian Qian; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2018-10-01       Impact factor: 4.668

10.  High efficiency, low distortion 3D diffusion tensor imaging with variable density spiral fast spin echoes (3D DW VDS RARE).

Authors:  Lawrence R Frank; Youngkyoo Jung; Souheil Inati; J Michael Tyszka; Eric C Wong
Journal:  Neuroimage       Date:  2009-09-22       Impact factor: 6.556

View more