Literature DB >> 23620069

Distant and delayed (>7 days) hemorrhage after treatment by flow-diverter stents in intracranial aneurysms: a rare but potentially serious complication.

F Clarençon, F Di Maria, A Biondi, J Chiras, N-A Sourour.   

Abstract

Entities:  

Mesh:

Year:  2013        PMID: 23620069      PMCID: PMC8051490          DOI: 10.3174/ajnr.A3597

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


× No keyword cloud information.
  3 in total

1.  Estimating the proportion of intracranial aneurysms likely to be amenable to treatment with the pipeline embolization device.

Authors:  Waleed Brinjikji; Harry J Cloft; David Fiorella; Giuseppe Lanzino; David F Kallmes
Journal:  J Neurointerv Surg       Date:  2011-12-02       Impact factor: 5.836

2.  Delayed ipsilateral parenchymal hemorrhage following flow diversion for the treatment of anterior circulation aneurysms.

Authors:  J P Cruz; M Chow; C O'Kelly; B Marotta; J Spears; W Montanera; D Fiorella; T Marotta
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-08       Impact factor: 3.825

3.  Revisiting the risk of intraparenchymal hemorrhage following aneurysm treatment by flow diversion.

Authors:  G P Colby; L-M Lin; A L Coon
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-21       Impact factor: 3.825

  3 in total
  4 in total

1.  In vitro, contrast agent-based evaluation of the influence of flow diverter size and position on intra-aneurysmal flow dynamics using syngo iFlow.

Authors:  Giorgio Franco Maria Cattaneo; Andreas Ding; Tobias Jost; Désirée Ley; Ruben Mühl-Bennighaus; Umut Yilmaz; Heiko Körner; Wolfgang Reith; Andreas Simgen
Journal:  Neuroradiology       Date:  2017-08-25       Impact factor: 2.804

2.  The Derivo Embolization Device, a Second-Generation Flow Diverter for the Treatment of Intracranial Aneurysms, Evaluated in an Elastase-Induced Aneurysm Model.

Authors:  D Ley; R Mühl-Benninghaus; U Yilmaz; H Körner; G F M Cattaneo; W Mailänder; Y-J Kim; B Scheller; W Reith; A Simgen
Journal:  Clin Neuroradiol       Date:  2015-12-23       Impact factor: 3.649

3.  Meta-Analysis of the Efficiency and Prognosis of Intracranial Aneurysm Treated with Flow Diverter Devices.

Authors:  Gengfan Ye; Meng Zhang; Lin Deng; Xiaohui Chen; Yunyan Wang
Journal:  J Mol Neurosci       Date:  2016-01-27       Impact factor: 3.444

Review 4.  Stents and Stent Mimickers in Endovascular Management of Wide-neck Intracranial Aneurysms.

Authors:  Yasir J Khattak; Ayman A Sibaie; Muhammad Anwar; Raza Sayani
Journal:  Cureus       Date:  2018-10-05
  4 in total