| Literature DB >> 23617328 |
Bardia Taghavi Bayat1, Suki Gill, Shankar Siva, Keen Hun Tai, Michael Lim Joon, Farshad Foroudi.
Abstract
BACKGROUND: The Royal Australian and New Zealand College of Radiologists (RANZCR) initiated a unique instrument to audit the quality of patient notes and radiotherapy prescriptions. We present our experience collected over ten years from the use of the RANZCR audit instrument.Entities:
Mesh:
Year: 2013 PMID: 23617328 PMCID: PMC3639063 DOI: 10.1186/1472-6963-13-148
Source DB: PubMed Journal: BMC Health Serv Res ISSN: 1472-6963 Impact factor: 2.655
Number of omissions for each criterion; and number corrected subsequently out of 2597 patients
| 1 | History recorded | 23 | 9 |
| 2 | Examination recorded | 3 | 1 |
| 3 | Primary tumour site correctly documented | 0 | 0 |
| 4 | Histology correctly documented and report filed | 45 | 29 |
| 5 | Relevant imaging of treated site correctly documented and reports filed | 105 | 48 |
| 6 | Tumour stage correctly documented | 5 | 2 |
| 7 | Rationale for radiotherapy documented | 0 | 0 |
| 8 | Treatment intent documented | 0 | 0 |
| 9 | Discussion of treatment risks and consent recorded | 0 | 0 |
| 10 | Letter or notes copied to referring doctor | 8 | 8 |
| Treatment prescription | |||
| 11 | Legible patient name is present on all prescriptions | 0 | 0 |
| 12 | Treatment site specified and correct | 0 | 0 |
| 13 | Laterality (i.e. ‘left’ or ‘right’) for treated site correctly documented | 1 | 1 |
| 14 | Radiation modality and energy for all phases | 0 | 0 |
| 15 | Total dose specified for all phases | 0 | 0 |
| 16 | Dose per fraction specified for all phases | 0 | 0 |
| 17 | RT dose point specified for all phases | 3 | 3 |
| 18 | Number of fractions/day specified for all phases | 0 | 0 |
| 19 | Number of fractions per week for all phases | 0 | 0 |
| 20 | Treatment prescriptions are signed/approved and dated | 0 | 0 |
| 21 | Isodoses/treatment plan signed/approved and dated by doctor | 0 | 0 |
| 22 | Legible and correct patient name on all simulation/VP film/electronic images | 0 | 0 |
| 23 | Simulation image is signed or approved and dated by doctor | 0 | 0 |
| 24 | Indication for treatment | 0 | 0 |
| 25 | Treatment intent (radical vs. palliative) | 0 | 0 |
| 26 | Target volume coverage | 0 | 0 |
| 27 | Critical structure doses | 0 | 0 |
| 28 | Prescribed total dose for each volume | 0 | 0 |
| 29 | Fractionation schedule | 0 | 0 |
| 30 | Clinical protocol or practice guideline followed | 0 | 0 |
| 31 | Research or Study followed | 0 | 0 |
| | (*for 6 patients the actual omission was unclearly documented). | 6 | 0 |
| Total | 199 | 101 | |