Literature DB >> 23614703

Can body surface microvolt T-wave alternans distinguish concordant and discordant intracardiac alternans?

Vincent Floré1, Piet Claus, Rolf Symons, Godfrey L Smith, Karin R Sipido, Rik Willems.   

Abstract

INTRODUCTION: There is convincing experimental evidence that cellular action potential duration (APD) alternans is arrhythmogenic but its relationship with body surface microvolt T-wave alternans (MTWA) remains unclear. We investigated the relationship between MTWA and APD alternans induced by alternating cycle length (CL) pacing in a pig model.
METHODS: In 10 pigs, catheters in the right atrium (RA) and right (RV) and left ventricle (LV) allowed pacing and recording of monophasic action potentials (MAP). During RA pacing at stable 500-ms CL, LV was paced at alternating CL (505 ms and 495 ms). Changing the alternating LV (A-LV) pacing delay changes the size of the region with alternating ventricular activation. Spectral analysis of intracardiac MAP was correlated with body surface MTWA. In a similar setup (during alternating pacing in RV and LV), we investigated concordant versus discordant APD alternans.
RESULTS: Pacing the LV with subtle alternating cycle lengths at short A-LV delay leads to broad QRS (97 ± 10 ms), body surface MTWA (mean Valt 4.2 ± 1.8 µV), and positive RR-interval alternans. At longer A-LV delay, not resulting in QRS widening (68 ± 5 ms), body surface RR alternans was absent but MTWA remained detectable and was even more pronounced (8.7 ± 5.1 µV, P < 0.01). During both concordant and discordant pacing MTWA was present. The precordial leads were better for detecting discordant APD alternans (8.0 ± 2.9 µV and 12.8 ± 4.52 µV, P = 0.02).
CONCLUSION: MTWA is a potent technique to detect subtle and isolated intracardiac APD alternans that is artificially induced by alternating pacing. In the same model, discordant activation alternans can only be discriminated from concordant when using a quantifying approach of MTWA analysis. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  T-wave alternans; action potential duration alternans

Mesh:

Year:  2013        PMID: 23614703     DOI: 10.1111/pace.12139

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

1.  Cardiac myocyte alternans in intact heart: Influence of cell-cell coupling and β-adrenergic stimulation.

Authors:  Karin P Hammer; Senka Ljubojevic; Crystal M Ripplinger; Burkert M Pieske; Donald M Bers
Journal:  J Mol Cell Cardiol       Date:  2015-03-28       Impact factor: 5.000

2.  A study of the clinical application value of ultrasound and electrocardiogram in the differential diagnosis of cardiomyopathy.

Authors:  Yanyan Zhao; Shibin Lin; Jingjing Wu; Jineng Lai; Lan Li
Journal:  Am J Transl Res       Date:  2021-05-15       Impact factor: 4.060

3.  A Potential-Based Inverse Spectral Method to Noninvasively Localize Discordant Distributions of Alternans on the Heart From the ECG.

Authors:  Jaume Coll-Font; Burak Erem; Dana H Brooks
Journal:  IEEE Trans Biomed Eng       Date:  2017-07-26       Impact factor: 4.538

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.