Literature DB >> 23614387

Repeatability, reliability and reproducibility of posterior curvature and wavefront aberrations in keratoconic and cross-linked corneas.

Haris Sideroudi1, Georgios Labiris, Athanassios Giarmoulakis, Najia Bougatsou, Dimitrios Mikropoulos, Vassilios Kozobolis.   

Abstract

BACKGROUND: The aim was to assess the intra-session, inter-session and inter-observer repeatability of curvature and aberrometric measurements of Pentacam-derived posterior corneal surface in normal control (CG), keratoconic (KCG) and after corneal collagen cross-linked (CXLG) groups.
METHODS: This was a prospective, clinic-based, observational study that was conducted at the Eye Institute of Thrace (EIT) in Alexandroupolis, Greece. Sixty-two normal eyes formed the control group, 33 were in the keratoconic group, while 34 eyes, which already had received corneal collagen cross-linking formed the CXLG. Curvature and aberrometric measurements were obtained using the Pentacam by two operators within each of the two sessions. Precision (Pre), repeatability (COR) and the intra-class correlation coefficient (ICC) were calculated for evaluating intra-session and inter-session repeatability. Bland-Altman analysis was used for assessing inter-observer repeatability.
RESULTS: Simulated keratometric parameters K1 and K2, asphericity at the central 8 mm zone (Q8) and central steepest radius of best fit toric ellipsoid reference body (Rs), achieved an acceptable level of accuracy. Aberrometric parameters were repeatable, reliable and reproducible only in terms of the root mean square (RMS) errors (coma, coma-like and the RMS of higher order aberrations or HOA RMS). For both observers, best precision and lowest range of agreement (ROA) was found for HOA RMS parameters in all groups (less than 0.27 and less than 0.29 for the control group, less than 0.95 and less than 0.72 for the keratoconic group and less than 0.67 and 0.53 for the collagen cross-linked group).
CONCLUSION: The Pentacam system provides precise measurements of corneal posterior keratometry, reference body radius and asphericity for large diameter analysis. Although Zernike coefficients for individuals presented poor repeatability, the coma, coma-like and HOA RMS seem to be accurate indices in characterisation of back corneal aberrations.
© 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

Entities:  

Keywords:  aberrations; collagen cross-linking; cornea; keratoconus

Mesh:

Substances:

Year:  2013        PMID: 23614387     DOI: 10.1111/cxo.12044

Source DB:  PubMed          Journal:  Clin Exp Optom        ISSN: 0816-4622            Impact factor:   2.742


  8 in total

1.  Validation of Fourier analysis of videokeratographic data.

Authors:  Haris Sideroudi; Georgios Labiris; Fienke Ditzel; Efi Tsaragli; Kimonas Georgatzoglou; Haralampos Siganos; Vassilios Kozobolis
Journal:  Int Ophthalmol       Date:  2017-06-15       Impact factor: 2.031

2.  Keratoconus after 40 years of age: a longitudinal comparative population-based study.

Authors:  Hassan Hashemi; Soheila Asgari; Shiva Mehravaran; Mohammad Hassan Emamian; Akbar Fotouhi
Journal:  Int Ophthalmol       Date:  2019-11-07       Impact factor: 2.031

3.  Changes in corneal aberrations after cataract surgery.

Authors:  Yuki Hidaka; Takefumi Yamaguchi; Megumi Saiki; Murat Dogru; Kazuo Tsubota; Kazuno Negishi
Journal:  Jpn J Ophthalmol       Date:  2016-03-02       Impact factor: 2.447

4.  OPD-Scan III: a repeatability and inter-device agreement study of a multifunctional device in emmetropia, ametropia, and keratoconus.

Authors:  Soheila Asgari; Hassan Hashemi; Ebrahim Jafarzadehpur; Alireza Mohamadi; Farhad Rezvan; Akbar Fotouhi
Journal:  Int Ophthalmol       Date:  2016-02-08       Impact factor: 2.031

5.  Repeatability of corneal elevation maps in keratoconus patients using the tomography matching method.

Authors:  YaRu Zheng; LiFang Huang; YiPing Zhao; JunJie Wang; XiaoBo Zheng; Wei Huang; Brendan Geraghty; QinMei Wang; ShiHao Chen; FangJun Bao; Ahmed Elsheikh
Journal:  Sci Rep       Date:  2017-12-12       Impact factor: 4.379

6.  The effect of corneal cross-linking on the anterior and posterior parameters of the cornea: A prospective repeatability study.

Authors:  Hassan Hashemi; Shiva Mehravaran; Soheila Asgari
Journal:  Rom J Ophthalmol       Date:  2019 Jan-Mar

7.  Repeatability and reproducibility of corneal higher-order aberrations measurements after small incision lenticule extraction using the Scheimpflug-Placido topographer.

Authors:  Rui Ning; Rongrong Gao; David P Piñero; Jun Zhang; Qingyi Gao; Yili Jin; Yiran Wang; Chenxiao Wang; Jinhai Huang
Journal:  Eye Vis (Lond)       Date:  2022-01-04

8.  Evaluation of corneal higher order aberrations in normal topographic patterns.

Authors:  Ali Mirzajani; Sattar Aghataheri; Mohammad Ghoreishi; Ebrahim Jafarzadepour; Mohadese Mohammadinia
Journal:  J Curr Ophthalmol       Date:  2016-04-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.