Literature DB >> 23611397

Comparison of Vibringe, EndoActivator, and needle irrigation on sealer penetration in extracted human teeth.

Jordan A Bolles1, Jianing He, Kathy K H Svoboda, Emet Schneiderman, Gerald N Glickman.   

Abstract

INTRODUCTION: Vibringe is a new device that allows continuous sonic irrigation of the canal system during endodontic treatment. The aim of this study was to compare the effect of different irrigation systems on sealer penetration into dentinal tubules of extracted single-rooted teeth.
METHODS: Fifty single-rooted human teeth were instrumented and randomly divided into 4 groups: group 1 (control), saline; group 2 (conventional irrigation), 17% EDTA followed by 6% NaOCl; group 3 (EndoActivator), same irrigants as group 2; group 4 (Vibringe), same irrigants as group 2. Obturation of all teeth was done with gutta-percha and SimpliSeal labeled with fluorescent dye. Transverse sections at 1 mm and 5 mm from the root apex were examined by using confocal laser scanning microscopy. Percentage and maximum depth of sealer penetration were measured by using NIS-Elements Br 3.0 imaging software.
RESULTS: Groups 3 and 4 had a significantly greater percentage of the canal wall penetrated by sealer at the 5-mm level than group 1 (P < .0125), but not group 2. No other differences were found between the groups at either section level for both the percentage of sealer penetration and maximum depth. The 5-mm sections in each experimental group had a significantly higher percentage and maximum depth of sealer penetration than did the 1-mm sections (P < .0125).
CONCLUSIONS: The use of sonic activation with either the EndoActivator or Vibringe did not significantly improve the sealer penetration when compared with conventional irrigation.
Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23611397     DOI: 10.1016/j.joen.2013.01.006

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  29 in total

1.  Influence of ultrasonic and sonic activation of epoxy-amine resin-based sealer on penetration of sealer into lateral canals.

Authors:  Hakan Arslan; Aneesh Abbas; Ertugrul Karatas
Journal:  Clin Oral Investig       Date:  2016-01-28       Impact factor: 3.573

Review 2.  Irrigation in endodontics.

Authors:  M Haapasalo; Y Shen; Z Wang; Y Gao
Journal:  Br Dent J       Date:  2014-03       Impact factor: 1.626

3.  The effect of final irrigation on the penetrability of an epoxy resin-based sealer into dentinal tubules: a confocal microscopy study.

Authors:  Alexander Pompermayer Jardine; Ricardo Abreu da Rosa; Manuela Favarin Santini; Márcia Wagner; Marcus Vinícius Reis Só; Milton Carlos Kuga; Jefferson Ricardo Pereira; Patrícia Maria Poli Kopper
Journal:  Clin Oral Investig       Date:  2015-04-24       Impact factor: 3.573

4.  Smear layer removal and sealer penetration with different tapers after using photon-initiated photoacoustic streaming technique.

Authors:  Islam Mohamed Eldeeb; Nawar Naguib Nawar; Shehabeldin Mohamed Saber; Ehab El-Sayed Hassanein; Edgar Schäfer
Journal:  Clin Oral Investig       Date:  2021-02-04       Impact factor: 3.573

5.  Effect of photon-initiated photoacoustic streaming, passive ultrasonic, and sonic irrigation techniques on dentinal tubule penetration of irrigation solution: a confocal microscopic study.

Authors:  Merve Akcay; Hakan Arslan; Merve Mese; Nazlı Durmus; Ismail Davut Capar
Journal:  Clin Oral Investig       Date:  2016-12-05       Impact factor: 3.573

6.  The effect of photon-initiated photoacoustic streaming, ultrasonically and sonically irrigation techniques on the push-out bond strength of a resin sealer to the root dentin.

Authors:  Merve Akcay; Hakan Arslan; Merve Mese; N Nur Sahin
Journal:  Clin Oral Investig       Date:  2014-10-15       Impact factor: 3.573

7.  Double dye technique and fluid filtration test to evaluate early sealing ability of an endodontic sealer.

Authors:  Luigi Generali; C Prati; C Pirani; F Cavani; M R Gatto; M G Gandolfi
Journal:  Clin Oral Investig       Date:  2016-06-14       Impact factor: 3.573

8.  Sealer penetration: effect of separated file's cross-section, taper and motion characteristics.

Authors:  Ayhan Eymirli; Emel Uzunoğlu Özyürek; Ahmet Serper
Journal:  Clin Oral Investig       Date:  2020-06-19       Impact factor: 3.573

9.  Dentinal Tubule Penetration of Tricalcium Silicate Sealers.

Authors:  Greer E McMichael; Carolyn M Primus; Lynne A Opperman
Journal:  J Endod       Date:  2016-02-19       Impact factor: 4.171

10.  Effectiveness of conventional syringe irrigation, vibringe, and passive ultrasonic irrigation performed with different irrigation regimes in removing triple antibiotic paste from simulated root canal irregularities.

Authors:  Hüseyin Sinan Topçuoğlu; Ahmet Aktı; Gamze Topçuoğlu; Salih Düzgün; Özge Ulusan; Firdevs Akpek
Journal:  J Conserv Dent       Date:  2016 Jul-Aug
View more