Literature DB >> 23608541

Ultrasensitive and selective gold film-based detection of mercury (II) in tap water using a laser scanning confocal imaging-surface plasmon resonance system in real time.

Hongyan Zhang1, Liquan Yang, Bingjiang Zhou, Weimin Liu, Jiechao Ge, Jiasheng Wu, Ying Wang, Pengfei Wang.   

Abstract

An ultrasensitive and selective detection of mercury (II) was investigated using a laser scanning confocal imaging-surface plasmon resonance system (LSCI-SPR). The detection limit was as low as 0.01ng/ml for Hg(2+) ions in ultrapure and tap water based on a T-rich, single-stranded DNA (ssDNA)-modified gold film, which can be individually manipulated using specific T-Hg(2+)-T complex formation. The quenching intensity of the fluorescence images for rhodamine-labeled ssDNA fitted well with the changes in SPR. The changes varied with the Hg(2+) ion concentration, which is unaffected by the presence of other metal ions. The coefficients obtained for ultrapure and tap water were 0.99902 and 0.99512, respectively, for the linear part over a range of 0.01-100ng/ml. The results show that the double-effect sensor has potential for practical applications with ultra sensitivity and selectivity, especially in online or real-time monitoring of Hg(2+) ions pollution in tap water with the further improvement of portable LSCI-SPR instrument.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23608541     DOI: 10.1016/j.bios.2013.03.067

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  Colorimetric detection of Hg(II) by measurement the color alterations from the "before" and "after" RGB images of etched triangular silver nanoplates.

Authors:  Li Li; Laiping Zhang; Yan Zhao; Zhengbo Chen
Journal:  Mikrochim Acta       Date:  2018-03-22       Impact factor: 5.833

2.  Indirect determination of mercury(II) by using magnetic nanoparticles, CdS quantum dots and mercury(II)-binding aptamers, and quantitation of released CdS by graphite furnace AAS.

Authors:  Arman Sharifi; Rahman Hallaj; Soleiman Bahar; Bahareh Babamiri
Journal:  Mikrochim Acta       Date:  2020-01-03       Impact factor: 5.833

3.  Luminescent turn-on detection of Hg(II) via the quenching of an iridium(III) complex by Hg(II)-mediated silver nanoparticles.

Authors:  Jinshui Liu; Kasipandi Vellaisamy; Guanjun Yang; Chung-Hang Leung; Dik-Lung Ma
Journal:  Sci Rep       Date:  2017-06-15       Impact factor: 4.379

Review 4.  Bio-Recognition in Spectroscopy-Based Biosensors for *Heavy Metals-Water and Waterborne Contamination Analysis.

Authors:  Alessandra Aloisi; Antonio Della Torre; Angelantonio De Benedetto; Rosaria Rinaldi
Journal:  Biosensors (Basel)       Date:  2019-07-30

Review 5.  Surface Plasmon Resonance Optical Sensor: A Review on Light Source Technology.

Authors:  Briliant Adhi Prabowo; Agnes Purwidyantri; Kou-Chen Liu
Journal:  Biosensors (Basel)       Date:  2018-08-26
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.