Erroneous continuous cardiac output by calibrated pulse contour analysis.

Jörn Grensemann1, Frank Wappler, Samir G Sakka.   

Abstract

Pulse contour analysis techniques are used for beat-to-beat tracking of cardiac output in critically ill patients. However, an adequate pulse pressure waveform signal and identification of the appropriate (i.e. systolic) part of the waveform by the monitor are crucial for correct calculation of continuous cardiac output. We observed a case where the monitor failed to correctly identify the systolic part of the waveform during tachycardia thus giving false readings. We would like to emphasize the importance of visually checking the waveform for any irregularities that may cause erroneous calculations before initiating a therapy based on these values. One advantage of the system used here is that the part of the pressure curve used for analysis is automatically indicated.

Entities:  

Mesh:

Year:  2013        PMID: 23604580     DOI: 10.1007/s10877-013-9470-5

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  3 in total

1.  Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability.

Authors:  Oliver Gödje; Kerstin Höke; Alwin E Goetz; Thomas W Felbinger; Daniel A Reuter; Bruno Reichart; Reinhard Friedl; Andreas Hannekum; Ulrich J Pfeiffer
Journal:  Crit Care Med       Date:  2002-01       Impact factor: 7.598

2.  Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: comparison with pulmonary arterial thermodilution.

Authors:  O Goedje; K Hoeke; M Lichtwarck-Aschoff; A Faltchauser; P Lamm; B Reichart
Journal:  Crit Care Med       Date:  1999-11       Impact factor: 7.598

3.  Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting.

Authors:  W Buhre; A Weyland; S Kazmaier; G G Hanekop; M M Baryalei; M Sydow; H Sonntag
Journal:  J Cardiothorac Vasc Anesth       Date:  1999-08       Impact factor: 2.628

  3 in total
  2 in total

1.  Effect of patent ductus arteriosus and patent foramen ovale on left ventricular stroke volume measurement by electrical velocimetry in comparison to transthoracic echocardiography in neonates.

Authors:  Martin Ernst Blohm; Jana Hartwich; Denise Obrecht; Jan Felix Kersten; Dominique Singer
Journal:  J Clin Monit Comput       Date:  2016-04-12       Impact factor: 2.502

Review 2.  Cardiac Output Monitoring by Pulse Contour Analysis, the Technical Basics of Less-Invasive Techniques.

Authors:  Jörn Grensemann
Journal:  Front Med (Lausanne)       Date:  2018-03-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.