Literature DB >> 23603644

A randomized controlled trial of cast versus splint for distal radial buckle fracture: an evaluation of satisfaction, convenience, and preference.

Kristine G Williams1, Gillian Smith, Scott J Luhmann, Jingnan Mao, Joseph D Gunn, Janet D Luhmann.   

Abstract

OBJECTIVES: Buckle fractures are inherently stable and at low risk for displacement. These advantages allow for treatment options that may create confusion for the practitioner. Accepted immobilization methods include circumferential cast, plaster or prefabricated splint, and soft bandaging. Despite mounting evidence for splinting, the questions of pain, preference, satisfaction, and convenience offer a challenge to changing practice. The purposes of this study were (1) to compare cast versus splint for distal radial buckle fractures in terms of parental and patient satisfaction, convenience, and preference and (2) to compare pain reported for cast versus splint.
METHODS: We conducted a prospective randomized trial of a convenience sample of patients 2 through 17 years with a radiologically confirmed distal radial buckle fracture. Subjects were randomly assigned to short-arm cast or prefabricated wrist splint. We assessed satisfaction, convenience, preference, and pain in the emergency department and at days 1, 3, 7, and 21 after immobilization.
RESULTS: Ninety-four patients were enrolled. Compared with the cast group, those in the splint group reported higher levels of satisfaction, preference, and convenience on 10-point visual analog scale. Although pain scores were higher for those in the splint group, the difference was not statistically significant.
CONCLUSIONS: With the exception of pain reported in the emergency department being higher for the splinted group, all other measures, including convenience, satisfaction, and preference, showed a clear trend favoring splints at almost every time period in the study. This study provides additional evidence that splinting is preferable to casting for the treatment of distal radial buckle fractures.

Entities:  

Mesh:

Year:  2013        PMID: 23603644     DOI: 10.1097/PEC.0b013e31828e56fb

Source DB:  PubMed          Journal:  Pediatr Emerg Care        ISSN: 0749-5161            Impact factor:   1.454


  22 in total

1.  Paediatrician office follow-up of common minor fractures.

Authors:  Eric Koelink; Kathy Boutis
Journal:  Paediatr Child Health       Date:  2014-10       Impact factor: 2.253

2.  Differentiating stable buckle fractures from other distal radius fractures: the 1-cm rule.

Authors:  Benjamin W Iles; Julie B Samora; Satbir Singh; Lynne Ruess
Journal:  Pediatr Radiol       Date:  2018-12-13

3.  The Use of 3D Printed Customized Casts in Children with Upper Extremity Fractures: A Report of Two Cases.

Authors:  Brian Katt; Casey Imbergamo; Daniel Seigerman; Michael Rivlin; Pedro K Beredjiklian
Journal:  Arch Bone Jt Surg       Date:  2021-01

4.  Offer of a bandage versus rigid immobilisation in 4- to 15-year-olds with distal radius torus fractures: the FORCE equivalence RCT.

Authors:  Daniel C Perry; Juul Achten; Ruth Knight; Susan J Dutton; Melina Dritsaki; James M Mason; Duncan E Appelbe; Damian T Roland; Shrouk Messahel; James Widnall; Phoebe Gibson; Jennifer Preston; Louise M Spoors; Marta Campolier; Matthew L Costa
Journal:  Health Technol Assess       Date:  2022-07       Impact factor: 4.106

5.  Conventional vs 3-Dimensional Printed Cast Wear Comfort.

Authors:  Jack Graham; Mark Wang; Kaela Frizzell; Cynthia Watkins; Pedro Beredjiklian; Michael Rivlin
Journal:  Hand (N Y)       Date:  2018-08-27

6.  Interventions for treating wrist fractures in children.

Authors:  Helen Hg Handoll; Joanne Elliott; Zipporah Iheozor-Ejiofor; James Hunter; Alexia Karantana
Journal:  Cochrane Database Syst Rev       Date:  2018-12-19

7.  Buckling Down on Torus Fractures - Assessing Treatment Preferences and Perceived Management Barriers at a Single Institution.

Authors:  Brendan A Williams; Sarah A Phillips; Robert C Matthias; Laurel C Blakemore
Journal:  Iowa Orthop J       Date:  2020

8.  Effect of a redesigned fracture management pathway and 'virtual' fracture clinic on ED performance.

Authors:  J Vardy; P J Jenkins; K Clark; M Chekroud; K Begbie; I Anthony; L A Rymaszewski; A J Ireland
Journal:  BMJ Open       Date:  2014-06-13       Impact factor: 2.692

9.  Factors affecting management of children's low-risk distal radius fractures in the emergency department: a population-based retrospective cohort study.

Authors:  Tara Baxter; Teresa To; Maria Chiu; Mark Camp; Andrew Howard
Journal:  CMAJ Open       Date:  2021-06-15

10.  What They Want - Caregiver and Patient Immobilization Preferences for Pediatric Buckle Fractures of the Wrist.

Authors:  Brendan A Williams; Noel E Palumbo; Sarah A Phillips; Laurel C Blakemore
Journal:  Iowa Orthop J       Date:  2020
View more