Literature DB >> 23601885

Disposable immunosensors for C-reactive protein based on carbon nanotubes field effect transistors.

Celine I L Justino1, Ana C Freitas, José P Amaral, Teresa A P Rocha-Santos, Susana Cardoso, Armando C Duarte.   

Abstract

Label-free immunosensors based on single-walled carbon nanotubes field effect transistor (NTFET) devices were developed for the detection of C-reactive protein (CRP) which is currently the best validated inflammatory biomarker associated with cardiovascular diseases. The immunoreaction principle consists in the direct adsorption of CRP specific antibodies (anti-CRP) to single-walled carbon nanotubes (SWCNTs) networks. Such anti-CRP are the molecular receptors of CRP antigens which, in turn, can be detected by the developed NTFET devices in a linear dynamic range of 10(-4)-10(2) μg/mL. Thus, typical values of CRP (in blood serum) for healthy persons (<1 μg/mL), and higher levels (>5 μg/mL) corresponding to pathological states, can be both detected with the NTFET immunosensors, becoming an advantageous alternative as the basis for the development of analytical instrumentation for assessment of risk of occurrence of cardiovascular diseases. A log-log linear regression was applied to the experimental data with a correlation coefficient of r=0.9962 (p<0.001), and there is no statistical difference (from ANOVA) between individual NTFET devices (p=0.9582), demonstrating acceptable reproducibility. According to the experimental results, the estimate of detection limit (LOD, 10(-4)μg/mL) is 3-fold lower than that of some conventional immunoassay techniques for blood serum (e.g., LOD of 0.2 μg/mL for high-sensitivity enzyme-linked immunosorbent assay), and the dynamic range (10(-4)-10(2)μg/mL) is about 6-fold higher. Furthermore, this simple and low-cost methodology allows the use of sample volumes as low as 1 μL for the label-free detection of CRP.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23601885     DOI: 10.1016/j.talanta.2013.03.007

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  12 in total

Review 1.  Critical overview on the application of sensors and biosensors for clinical analysis.

Authors:  Celine I L Justino; Armando C Duarte; Teresa A P Rocha-Santos
Journal:  Trends Analyt Chem       Date:  2016-04-08       Impact factor: 12.296

Review 2.  Recent trends in carbon nanomaterial-based electrochemical sensors for biomolecules: A review.

Authors:  Cheng Yang; Madelaine E Denno; Poojan Pyakurel; B Jill Venton
Journal:  Anal Chim Acta       Date:  2015-07-07       Impact factor: 6.558

3.  Dynamic Range Expansion of the C-Reactive Protein Quantification with a Tandem Giant Magnetoresistance Biosensor.

Authors:  Fanda Meng; Lei Zhang; Weisong Huo; Jie Lian; Aldo Jesorka; Xizeng Shi; Yunhua Gao
Journal:  ACS Omega       Date:  2021-05-07

4.  Low-cost photolithographic fabrication of nanowires and microfilters for advanced bioassay devices.

Authors:  Nhi M Doan; Liangliang Qiang; Zhe Li; Santhisagar Vaddiraju; Gregory W Bishop; James F Rusling; Fotios Papadimitrakopoulos
Journal:  Sensors (Basel)       Date:  2015-03-12       Impact factor: 3.576

Review 5.  Sensors and Biosensors for C-Reactive Protein, Temperature and pH, and Their Applications for Monitoring Wound Healing: A Review.

Authors:  Pietro Salvo; Valentina Dini; Arno Kirchhain; Agata Janowska; Teresa Oranges; Andrea Chiricozzi; Tommaso Lomonaco; Fabio Di Francesco; Marco Romanelli
Journal:  Sensors (Basel)       Date:  2017-12-19       Impact factor: 3.576

Review 6.  Electrochemical sensing: A prognostic tool in the fight against COVID-19.

Authors:  Sharda Kotru; Martin Klimuntowski; Hashim Ridha; Zakir Uddin; Ali A Askhar; Gurmit Singh; Matiar M R Howlader
Journal:  Trends Analyt Chem       Date:  2021-01-23       Impact factor: 14.908

7.  Buried-Gate MWCNT FET-Based Nanobiosensing Device for Real-Time Detection of CRP.

Authors:  Ali Firoozbakhtian; Ali Hossein Rezayan; Hassan Hajghassem; Fereshteh Rahimi; Masoud Faraghi Ghazani; Mahsa Kalantar; Amir Mohamadsharifi
Journal:  ACS Omega       Date:  2022-02-14

Review 8.  State of the art of colloidal particles and unique interfaces-based SARS-CoV-2 detection methods and COVID-19 diagnosis.

Authors:  Ebru Saatçi; Satheesh Natarajan
Journal:  Curr Opin Colloid Interface Sci       Date:  2021-05-29       Impact factor: 6.448

Review 9.  Recent Progress in Nanomaterial-Based Electrochemical Biosensors for Cancer Biomarkers: A Review.

Authors:  Baozhen Wang; Uichi Akiba; Jun-Ichi Anzai
Journal:  Molecules       Date:  2017-06-24       Impact factor: 4.411

10.  Label-Free Electrochemical Immunoassay for C-Reactive Protein.

Authors:  Madasamy Thangamuthu; Christian Santschi; Olivier J F Martin
Journal:  Biosensors (Basel)       Date:  2018-03-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.