Literature DB >> 23595372

Correlation between contrast sensitivity and the lens opacities classification system III in age-related nuclear and cortical cataracts.

Yong Cheng1, Xuan Shi, Xiao-guang Cao, Xiao-xin Li, Yong-zhen Bao.   

Abstract

BACKGROUND: Contrast sensitivity (CS) testing can detect differences in functional vision and is highly correlated with visual performance. This study was designed to investigate the association between CS and the grading score using the lens opacities classification system (LOCS) III as well as the association between CS and visual acuity (VA) in nuclear or cortical age-related cataract (ARC) patients.
METHODS: A total of 270 eyes with ARC and 30 control eyes were divided into nuclear opacity (NO), nuclear color (NC), cortical cataract (C) based on LOCS III. The CS values measured at all spatial frequencies under photopic and glare conditions that resulted in contrast sensitivity function (CSF) were evaluated, and LogMAR VA was tested with the Early Treatment Diabetic Retinopathy Study (ETDRS) chart. The correlation between CSF and LOCS III grading scores, and between CSF and LogMAR VA were analyzed.
RESULTS: Compared to the controls, CSF of the nuclear or cortical ARC significantly declined. There are significant correlation between CSF and LogMAR VA, and between CSF and LOCS III grading scores. Compared to the VA, a stronger correlation existed between CSF and LOCS III grading score than that of LogMAR VA and LOCS III grading score. CS at some spatial frequencies is significantly influenced with LOCS III grading score.
CONCLUSIONS: CSF significantly declined with the increasing ARC grading scores. Comparing to VA, CSF reflected the severity of cataract more comprehensively. CS at low spatial frequency is significantly influenced by ARC. Therefore, CS is more precise than VA in assessing the visual function of ARC patients.

Entities:  

Mesh:

Year:  2013        PMID: 23595372

Source DB:  PubMed          Journal:  Chin Med J (Engl)        ISSN: 0366-6999            Impact factor:   2.628


  5 in total

1.  SPARCS and Pelli-Robson contrast sensitivity testing in normal controls and patients with cataract.

Authors:  L Gupta; V Cvintal; R Delvadia; Y Sun; E Erdem; C Zangalli; L Lu; S S Wizov; J Richman; E Spaeth; G L Spaeth
Journal:  Eye (Lond)       Date:  2017-01-20       Impact factor: 3.775

2.  Contrast sensitivity and its determinants in people with diabetes: SN-DREAMS-II, Report No 6.

Authors:  L Gella; R Raman; S S Pal; S Ganesan; T Sharma
Journal:  Eye (Lond)       Date:  2016-11-18       Impact factor: 3.775

3.  Association of optical cataract indices with cataract severity and visual function.

Authors:  Rodrigo Guimaraes de Souza; Abhinav Golla; Mahmood Khan; Ildamaris Montes de Oca; Sumitra Khandelwal; Zaina Al-Mohtaseb
Journal:  Int Ophthalmol       Date:  2021-08-10       Impact factor: 2.031

4.  Contrast sensitivity in Idiopathic Intracranial Hypertension.

Authors:  Obaidur Rehman; Parul Ichhpujani; Suresh Kumar
Journal:  Rom J Ophthalmol       Date:  2020 Oct-Dec

5.  Expressions of Senescence-Associated β-Galactosidase and Senescence Marker Protein-30 are Associated with Lens Epithelial Cell Apoptosis.

Authors:  Dan Zhou; Dan Yin; Fang Xiao; Jie Hao
Journal:  Med Sci Monit       Date:  2015-11-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.