Literature DB >> 23590774

Excellent results of primary THA using a highly porous titanium cup.

Qais Naziri1, Kimona Issa, Robert Pivec, Steven F Harwin, Ronald E Delanois, Michael A Mont.   

Abstract

Cementless acetabular cups for primary total hip arthroplasty have had excellent results, with failure rates typically less than 5% at up to 10-year follow-up. Tritanium is a 3-dimensional metal interface that has been used for porous biological fixation. The purpose of this study was to review the clinical and radiographic results of the use of Tritanium cups (Stryker Orthopaedics, Mahwah, New Jersey) for primary total hip arthroplasty. Two hundred eighty-eight total hip arthroplasties performed using a porous titanium acetabular cup in 252 patients between 2008 and 2010 were reviewed. One hundred thirty-three men and 119 women with a mean age of 58 years (range, 18-88 years) were included. Mean follow-up was 36 months (range, 24-56 months). Outcomes evaluated were implant survivorship, Harris Hip Score, complications, and radiographic outcomes. At final follow-up, no cup failures had occurred. Mean Harris Hip Score improved from 53 points (range, 33-82 points) preoperatively to 91 points (range, 64-100 points) postoperatively. One complication occurred; a 64-year-old woman with recurrent postoperative effusions underwent hip exploration and required abductor mechanism repair. On radiologic evaluation, no signs existed of progressive radiolucencies or changes in cup position. The survivorship of the Tritanium cup and the low complication rate is comparable with previous studies using other porous-metal prostheses. Longer follow-up study is needed and assessment of the results of using this implant in the revision setting is important. Copyright 2013, SLACK Incorporated.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23590774     DOI: 10.3928/01477447-20130327-10

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  9 in total

1.  Highly Porous Titanium Cups versus Hydroxyapatite-Coated Sockets: Midterm Results in Metachronous Bilateral Total Hip Arthroplasty.

Authors:  Francesco Castagnini; Barbara Bordini; Makiko Yorifuji; Federico Giardina; Simone Natali; Francesco Pardo; Francesco Traina
Journal:  Med Princ Pract       Date:  2019-05-13       Impact factor: 1.927

2.  Acute total hip arthroplasty in acetabular fractures using modern porous metal cup.

Authors:  Rajesh Malhotra; Deepak Gautam
Journal:  J Orthop Surg (Hong Kong)       Date:  2019 May-Aug       Impact factor: 1.118

3.  Radiographic assessment of radiolucent lines around a highly porous titanium cup (Tritanium) using digital tomosynthesis, after total hip arthroplasty.

Authors:  Kazuki Oishi; Yuji Yamamoto; Yoshifumi Harada; Ryo Inoue; Eiji Sasaki; Yasuyuki Ishibashi
Journal:  J Orthop Surg Res       Date:  2021-04-15       Impact factor: 2.359

4.  Clinical and radiographic outcomes of a trabecular titanium™ acetabular component in hip arthroplasty: results at minimum 5 years follow-up.

Authors:  Loris Perticarini; Giacomo Zanon; Stefano Marco Paolo Rossi; Francesco M Benazzo
Journal:  BMC Musculoskelet Disord       Date:  2015-12-03       Impact factor: 2.362

5.  Radiolucencies surrounding acetabular components with three-dimensional coatings: artifact or real?

Authors:  Ahmad Faizan; Philip Chuang; Carlos Aponte; Vincent Moretti; Peter F Sharkey
Journal:  Arthroplast Today       Date:  2017-07-26

6.  Early aseptic loosening of the Tritanium primary acetabular component with screw fixation.

Authors:  William J Long; Samir Nayyar; Kevin K Chen; David Novikov; Roy I Davidovitch; Jonathan M Vigdorchik
Journal:  Arthroplast Today       Date:  2018-01-02

7.  Evaluation of the bone morphology around four types of porous metal implants placed in distal femur of ovariectomized rats.

Authors:  Stanislav Bondarenko; Nataliya Ashukina; Valentyna Maltseva; Gennadiy Ivanov; Ahmed Amine Badnaoui; Ran Schwarzkopf
Journal:  J Orthop Surg Res       Date:  2020-08-03       Impact factor: 2.359

8.  Comparison of the Primary Stability of Porous Tantalum and Titanium Acetabular Revision Constructs.

Authors:  Nicholas A Beckmann; Rudi G Bitsch; Mareike Schonhoff; Klaus-Arno Siebenrock; Martin Schwarze; Sebastian Jaeger
Journal:  Materials (Basel)       Date:  2020-04-10       Impact factor: 3.623

9.  Multiacquisition Variable-Resonance Image Combination Magnetic Resonance Imaging Used to Study Detailed Bone Apposition and Fixation of an Additively Manufactured Cementless Acetabular Shell.

Authors:  Vignesh K Alamanda; Ivan Demartino; Hollis G Potter; Matthew F Koff; Bin Lin; Ahava Muskat; Geoffrey H Westrich
Journal:  Arthroplast Today       Date:  2020-08-26