Literature DB >> 23589187

JPEG2000 still image coding quality.

Tzong-Jer Chen1, Sheng-Chieh Lin, You-Chen Lin, Ren-Gui Cheng, Li-Hui Lin, Wei Wu.   

Abstract

This work demonstrates the image qualities between two popular JPEG2000 programs. Two medical image compression algorithms are both coded using JPEG2000, but they are different regarding the interface, convenience, speed of computation, and their characteristic options influenced by the encoder, quantization, tiling, etc. The differences in image quality and compression ratio are also affected by the modality and compression algorithm implementation. Do they provide the same quality? The qualities of compressed medical images from two image compression programs named Apollo and JJ2000 were evaluated extensively using objective metrics. These algorithms were applied to three medical image modalities at various compression ratios ranging from 10:1 to 100:1. Following that, the quality of the reconstructed images was evaluated using five objective metrics. The Spearman rank correlation coefficients were measured under every metric in the two programs. We found that JJ2000 and Apollo exhibited indistinguishable image quality for all images evaluated using the above five metrics (r > 0.98, p < 0.001). It can be concluded that the image quality of the JJ2000 and Apollo algorithms is statistically equivalent for medical image compression.

Entities:  

Mesh:

Year:  2013        PMID: 23589187      PMCID: PMC3782606          DOI: 10.1007/s10278-013-9603-x

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  16 in total

1.  Evaluation of JPEG and wavelet compression of body CT images for direct digital teleradiologic transmission.

Authors:  A Kalyanpur; V P Neklesa; C R Taylor; A R Daftary; J A Brink
Journal:  Radiology       Date:  2000-12       Impact factor: 11.105

2.  Comparison of image compression viability for lossy and lossless JPEG and Wavelet data reduction in coronary angiography.

Authors:  R Brennecke; U Bürgel; G Rippin; F Post; H J Rupprecht; J Meyer
Journal:  Int J Cardiovasc Imaging       Date:  2001-02       Impact factor: 2.357

3.  A comparison of two compression algorithms and the detection of caries.

Authors:  A Janhom; P F van der Stelt; G C H Sanderink
Journal:  Dentomaxillofac Radiol       Date:  2002-07       Impact factor: 2.419

4.  Irreversible compression of medical images.

Authors:  Bradley J Erickson
Journal:  J Digit Imaging       Date:  2002-04-30       Impact factor: 4.056

5.  A novel image quality index using Moran I statistics.

Authors:  Tzong-Jer Chen; Keh-Shih Chuang; Jay Wu; Sharon C Chen; Ing-Ming Hwang; Meei-Ling Jan
Journal:  Phys Med Biol       Date:  2003-04-21       Impact factor: 3.609

6.  A comparison of three image fidelity metrics of different computational principles for JPEG2000 compressed abdomen CT images.

Authors:  Kil Joong Kim; Bohyoung Kim; Rafal Mantiuk; Thomas Richter; Hyunna Lee; Heung-Sik Kang; Jinwook Seo; Kyoung Ho Lee
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

7.  Definition of compression ratio: difference between two commercial JPEG2000 program libraries.

Authors:  Kil Joong Kim; Bohyoung Kim; Seung Wook Choi; Young Hoon Kim; Seokyung Hahn; Tae Jung Kim; Soon Joo Cha; Vasundhara Bajpai; Kyoung Ho Lee
Journal:  Telemed J E Health       Date:  2008-05       Impact factor: 3.536

8.  Methods and limits of digital image compression of retinal images for telemedicine.

Authors:  R H Eikelboom; K Yogesan; C J Barry; I J Constable; M L Tay-Kearney; L Jitskaia; P H House
Journal:  Invest Ophthalmol Vis Sci       Date:  2000-06       Impact factor: 4.799

9.  Automated optimization of JPEG 2000 encoder options based on model observer performance for detecting variable signals in X-ray coronary angiograms.

Authors:  Yani Zhang; Binh T Pham; Miguel P Eckstein
Journal:  IEEE Trans Med Imaging       Date:  2004-04       Impact factor: 10.048

10.  Effects of JPEG and wavelet compression of spiral low-dose ct images on detection of small lung cancers.

Authors:  F Li; S Sone; S Takashima; K Kiyono; Z G Yang; M Hasegawa; S Kawakami; A Saito; K Hanamura; K Asakura
Journal:  Acta Radiol       Date:  2001-03       Impact factor: 1.701

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.